73 research outputs found

    Pitch Comparisons between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Normal-hearing Contralateral Ear

    Get PDF
    Four cochlear implant users, having normal hearing in the unimplanted ear, compared the pitches of electrical and acoustic stimuli presented to the two ears. Comparisons were between 1,031-pps pulse trains and pure tones or between 12 and 25-pps electric pulse trains and bandpass-filtered acoustic pulse trains of the same rate. Three methods—pitch adjustment, constant stimuli, and interleaved adaptive procedures—were used. For all methods, we showed that the results can be strongly influenced by non-sensory biases arising from the range of acoustic stimuli presented, and proposed a series of checks that should be made to alert the experimenter to those biases. We then showed that the results of comparisons that survived these checks do not deviate consistently from the predictions of a widely-used cochlear frequency-to-place formula or of a computational cochlear model. We also demonstrate that substantial range effects occur with other widely used experimental methods, even for normal-hearing listeners

    Gap-induced reductions of evoked potentials in the auditory cortex: a possible objective marker for the presence of tinnitus in animals

    Get PDF
    Animal models of tinnitus are essential for determining the underlying mechanisms and testing pharmacotherapies. However, there is doubt over the validity of current behavioural methods for detecting tinnitus. Here, we applied a stimulus paradigm widely used in a behavioural test (gap-induced inhibition of the acoustic startle reflex GPIAS) while recording from the auditory cortex, and showed neural response changes that mirror those found in the behavioural tests. We implanted guinea pigs (GPs) with electrocorticographic (ECoG) arrays and recorded baseline auditory cortical responses to a startling stimulus. When a gap was inserted in otherwise continuous background noise prior to the startling stimulus, there was a clear reduction in the subsequent evoked response (termed gap-induced reductions in evoked potentials; GIREP), suggestive of a neural analogue of the GPIAS test. We then unilaterally exposed guinea pigs to narrowband noise (left ear; 8-10 kHz; 1 hour) at one of two different sound levels - either 105 dB SPL or 120 dB SPL – and recorded the same responses seven-to-ten weeks following the noise exposure. Significant deficits in GIREP were observed for all areas of the auditory cortex (AC) in the 120 dB-exposed GPs, but not in the 105 dB-exposed GPs. These deficits could not simply be accounted for by changes in response amplitudes. Furthermore, in the contralateral (right) caudal AC we observed a significant increase in evoked potential amplitudes across narrowband background frequencies in both 105 dB and 120 dB-exposed GPs. Taken in the context of the large body of literature that has used the behavioural test as a demonstration of the presence of tinnitus, these results are suggestive of objective neural correlates of the presence of noise-induced tinnitus and hyperacusis

    Tinnitus: Distinguishing between Subjectively Perceived Loudness and Tinnitus-Related Distress

    Get PDF
    OBJECTIVES: Overall success of current tinnitus therapies is low, which may be due to the heterogeneity of tinnitus patients. Therefore, subclassification of tinnitus patients is expected to improve therapeutic allocation, which, in turn, is hoped to improve therapeutic success for the individual patient. The present study aims to define factors that differentially influence subjectively perceived tinnitus loudness and tinnitus-related distress. METHODS: In a questionnaire-based cross-sectional survey, the data of 4705 individuals with tinnitus were analyzed. The self-report questionnaire contained items about subjective tinnitus loudness, type of onset, awareness and localization of the tinnitus, hearing impairment, chronic comorbidities, sleep quality, and psychometrically validated questionnaires addressing tinnitus-related distress, depressivity, anxiety, and somatic symptom severity. In a binary step-wise logistic regression model, we tested the predictive power of these variables on subjective tinnitus loudness and tinnitus-related distress. RESULTS: The present data contribute to the distinction between subjective tinnitus loudness and tinnitus-related distress. Whereas subjective loudness was associated with permanent awareness and binaural localization of the tinnitus, tinnitus-related distress was associated with depressivity, anxiety, and somatic symptom severity. CONCLUSIONS: Subjective tinnitus loudness and the potential presence of severe depressivity, anxiety, and somatic symptom severity should be assessed separately from tinnitus-related distress. If loud tinnitus is the major complaint together with mild or moderate tinnitus-related distress, therapies should focus on auditory perception. If levels of depressivity, anxiety or somatic symptom severity are severe, therapies and further diagnosis should focus on these symptoms at first

    Perception of Vibrotactile Cues in Musical Performance

    Get PDF
    We suggest that studies on active touch psychophysics are needed to inform the design of haptic musical interfaces and better understand the relevance of haptic cues in musical performance. Following a review of the previous literature on vibrotactile perception in musical performance, two recent experiments are reported. The first experiment investigated how active finger-pressing forces affect vibration perception, finding significant effects of vibration type and force level on perceptual thresholds. Moreover, the measured thresholds were considerably lower than those reported in the literature, possibly due to the concurrent effect of large (unconstrained) finger contact areas, active pressing forces, and long-duration stimuli. The second experiment assessed the validity of these findings in a real musical context by studying the detection of vibrotactile cues at the keyboard of a grand and an upright piano. Sensitivity to key vibrations in fact not only was highest at the lower octaves and gradually decreased toward higher pitches; it was also significant for stimuli having spectral peaks of acceleration similar to those of the first experiment, i.e., below the standard sensitivity thresholds measured for sinusoidal vibrations under passive touch conditions

    Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation

    Get PDF
    Abstract Purpose There is concern that some generic preference based measures (GPMs) of health-related quality of life may be insensitive to interventions that improve hearing. Establishing where sensitivity arises could contribute to the design of improved measures. Accordingly, we compared the sensitivity of four widely-used GPMs to a clinically effective treatment – cochlear implantation – which restores material degrees of hearing to adults with little or no functional hearing. Methods Participants (N=147) received implants in any of 13 hospitals in the UK. One month before implantation and nine months after, they completed the HUI2, HUI3, EQ 5D 3L, and SF-6D questionnaires, together with the EuroQoL visual analogue scale as a direct measure of health, a performance test of speech reception, and a self-report measure of annoyance due to tinnitus. Results Implantation was associated with a large improvement in speech reception and a small improvement in tinnitus. HUI2 and HUI3 were sensitive to the improvement in speech reception through their Sensation and Hearing dimensions; EQ 5D 3L was sensitive to the improvement in tinnitus through its Anxiety/Depression dimension; SF-6D was sensitive to neither. Participants reported no overall improvement in health. Variation in health was associated with variation in tinnitus, not variation in speech reception. Conclusions None of the four GPMs was sensitive to the improvements in both speech reception and tinnitus that were associated with cochlear implantation. To capture fully the benefits of interventions for auditory disorders, developments of current GPMs would need to be sensitive to both the health-related and non-health-related aspects of auditory dysfunction

    Intraindividuelle Variabilität bei Tinnituspatienten

    No full text
    Most tinnitus studies have attempted to compare groups of individuals, thus revealing inter-individuals differences, i.e., variations between compared subjects. For methodological reasons, inter-individual studies cannot take into account the variability of tinnitus experience, which has been known for decades to be relevant in daily practice with tinnitus patients. The concept of intra-individual variability has been promoted in the research literature, in order to shed light on this aspect of individual perception. In previous studies, unrelated to hearing, the concept of intra-individual variability implied inclusion of the environment (i.e., physical and social interactions) as a factor of individual performance. In tinnitus research, we believe that the concept of variability (within a person) could find a place beside the concept of variation (between groups ofsubjects). In this paper, four perspectives of tinnitus experiences from the clinical and research fields are described: (1) ENT consultation; (2)short-term group psychotherapy; (3) psychodynamic psychotherapy; and (4) clinical psychological research. Intra-individual variability stresses the importance of defining tinnitus in a dynamic way, contrary to the current definition of tinnitus as the perception of sound(s). In clinical practice, it is useful to embrace the perspective of the perceiver of tinnitus, and to include social and cultural circumstances as well as audiological/physical changes

    Dépistage des troubles de l’audition : une leçon de respect de l’autre

    No full text
    International audienc
    • …
    corecore