21 research outputs found

    Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

    Get PDF
    The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $25

    A 13

    No full text

    The socioeconomic impact of truffle cultivation in rural Spain

    No full text
    The Socioeconomic Impact of Truffle Cultivation in Rural Spain. Commercial black truffle (Tuber melanosporum) plantations have been promoted in Europe with the intention of benefiting rural economies while conserving biodiversity through the expansion of oak woodlands. In this context, a socioeconomic study was conducted around the town of Sarrión in eastern Spain, where government subsidies have supported oak reforestation and truffle cultivation in unproductive hilly areas since 1987. Currently there are about 4,500 ha of truffle orchards in the surrounding county and 530 members in the local truffle association, which has provided a key forum for truffle cultivators to share technical, financial and administrative experiences. Structured interviews were carried out in 2002 with a number of orchard owners, as well as representatives of financial and governmental institutions. Truffles, which are harvested using trained dogs, typically fetch local cultivators average prices of 220–670 EUR/kg, although retail prices of high-quality specimens may reach twice this amount. In addition to the direct economic impact, an increase in local land prices was also documented, as well as a tendency for continued expansion of truffle orchards, and thus oak reforestation. In conclusion, the promotion of truffle cultivation through autonomous community and provincial government subsidies, in conjunction with support by local banks, a dedicated local truffle association, and growing interest on behalf of local farmers, seems to have achieved the mutual goals of biodiversity conservation and improving the rural economy in this region of Spain
    corecore