183 research outputs found

    Concentration and source origin of lanthanoids in the Canadian atmospheric particulate matter: a case study

    Get PDF
    AbstractAmbient PM2.5 and PM2.5–10 samples collected at selected urban and rural sites within the Canadian National Air Pollution Surveillance (NAPS) PM2.5 Speciation Program were analyzed for lanthanoids and other elements. The average concentrations of total lanthanoids (calculated as sum of concentrations of all elements) in PM2.5 ranged from 0.059 to 0.334ng m−3. These concentrations were two times lower than in PM2.5–10 samples and generally lower than values reported for industrial and urban areas around the world. The highest concentrations of lanthanoids were found in PM2.5 samples collected at the Halifax NS site, located near a petroleum refining complex. In addition, La/Ce and La/Sm ratios at this site were significantly higher than their natural values. Increased La–enrichment factors were also found in Wallaceburg ON, which is located in a rural area, about 50km downwind of two major petrochemical complexes. The results of this study demonstrate that La–enrichment factors are reliable tracers of emissions from oil refining industry

    Sources of particulate matter components in the Athabasca oil sands region: investigation through a comparison of trace element measurement methodologies

    Get PDF
    The province of Alberta, Canada, is home to three oil sands regions which, combined, contain the third largest deposit of oil in the world. Of these, the Athabasca oil sands region is the largest. As part of Environment and Climate Change Canada's program in support of the Joint Canada-Alberta Implementation Plan for Oil Sands Monitoring program, concentrations of trace elements in PM2. 5 (particulate matter smaller than 2.5 µm in diameter) were measured through two campaigns that involved different methodologies: a long-term filter campaign and a short-term intensive campaign. In the long-term campaign, 24 h filter samples were collected once every 6 days over a 2-year period (December 2010–November 2012) at three air monitoring stations in the regional municipality of Wood Buffalo. For the intensive campaign (August 2013), hourly measurements were made with an online instrument at one air monitoring station; daily filter samples were also collected. The hourly and 24 h filter data were analyzed individually using positive matrix factorization. Seven emission sources of PM2. 5 trace elements were thereby identified: two types of upgrader emissions, soil, haul road dust, biomass burning, and two sources of mixed origin. The upgrader emissions, soil, and haul road dust sources were identified through both the methodologies and both methodologies identified a mixed source, but these exhibited more differences than similarities. The second upgrader emissions and biomass burning sources were only resolved by the hourly and filter methodologies, respectively. The similarity of the receptor modeling results from the two methodologies provided reassurance as to the identity of the sources. Overall, much of the PM2. 5-related trace elements were found to be anthropogenic, or at least to be aerosolized through anthropogenic activities. These emissions may in part explain the previously reported higher levels of trace elements in snow, water, and biota samples collected near the oil sands operations

    Contrasting biological potency of particulate matter collected at sites impacted by distinct industrial sources

    Get PDF
    Association of biological effects in A549 cells with metal content in size-fractionated particles. Cytotoxic potencies according to lactate dehydrogenase (LDH) release and resazurin reduction were regressed against total, water-soluble, and non-water-soluble metals. Pearson product–moment correlation coefficient r-values are presented. LDH release. A) Total metals. UFP, r = 0.77, p = 0.13; PM0.1–2.5, r = −0.55, p = 0.34; PM2.5–10, r = 0.32, p = 0.60; PM>10, r = −0.68, p = 0.21. B) Water-soluble metals. UFP, r = 0.51, p = 0.38; PM0.1–2.5, r = −0.64, p = 0.25; PM2.5–10, r = −0.35, p = 0.57; PM>10, r = −0.68, p = 0.20. C) Non-water-soluble metals. UFP, r = 0.75, p = 0.14; PM0.1–2.5, r = −0.46, p = 0.43; PM2.5–10, r = 0.36, p = 0.55; PM>10, r = −0.68, p = 0.21. Resazurin reduction. D) UFP, r = −0.19, p = 0.76; PM0.1–2.5, r = −0.63, p = 0.26; PM2.5–10, r = −0.60, p = 0.28; PM>10,r = 0.18, p = 0.78. Water-soluble metals. UFP, r = −0.20, p = 0.74; PM0.1–2.5, r = −0.41, p = 0.49; PM2.5–10, r = −0.09, p = 0.88; PM>10, r = 0.04, p = 0.95. Non-water-soluble metals. UFP, r = −0.12, p = 0.84; PM0.1–2.5, r = −0.65, p = 0.24; PM2.5–10, r = −0.62, p = 0.26; PM>10, r = 0.18, p = 0.77. (PDF 43 kb

    Insights from a chronology of the development of atmospheric composition monitoring networks since the 1800s

    Get PDF
    Ground-based monitoring networks for evaluating atmospheric composition relevant to impacts on human health and the environment now exist worldwide (according to the United Nations Environment Programme, 48% of countries have an air quality monitoring system). Of course, this has not always been the case. Here, we analyse for the first time the key developments in network coordination and standardisation over the last 150 years that underpin the current implementations of city-scale to global monitoring networks for atmospheric composition. Examples include improvements in respect of site type and site representativeness, measurement methods, quality assurance, and data archiving. From the 1950s, these developments have progressed through two distinct types of network: those designed for the protection of human health, and those designed to increase scientific understanding of atmospheric composition and its interaction with the terrestrial environment. The step changes in network coordination and standardisation have increased confidence in the comparability of measurements made at different sites. Acknowledged limitations in the current state of monitoring networks include a sole focus on compliance monitoring. In the context of the unprecedented volumes of atmospheric composition data now being collected, we suggest the next developments in network standardisation should include more integrated analyses of monitor and other relevant data within “chemical climatology” frameworks that seek to more directly link the impacts, state and drivers of atmospheric composition. These approaches would also enhance the role of monitoring networks in the development and evaluation of air pollution mitigation strategies

    Exploring Variation and Predictors of Residential Fine Particulate Matter Infiltration

    Get PDF
    Although individuals spend the majority of their time indoors, most epidemiological studies estimate personal air pollution exposures based on outdoor levels. This almost certainly results in exposure misclassification as pollutant infiltration varies between homes. However, it is often not possible to collect detailed measures of infiltration for individual homes in large-scale epidemiological studies and thus there is currently a need to develop models that can be used to predict these values. To address this need, we examined infiltration of fine particulate matter (PM2.5) and identified determinants of infiltration for 46 residential homes in Toronto, Canada. Infiltration was estimated using the indoor/outdoor sulphur ratio and information on hypothesized predictors of infiltration were collected using questionnaires and publicly available databases. Multiple linear regression was used to develop the models. Mean infiltration was 0.52 ± 0.21 with no significant difference across heating and non-heating seasons. Predictors of infiltration were air exchange, presence of central air conditioning, and forced air heating. These variables accounted for 38% of the variability in infiltration. Without air exchange, the model accounted for 26% of the variability. Effective modelling of infiltration in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of infiltration

    Apparent Temperature and Air Pollution vs. Elderly Population Mortality in Metro Vancouver

    Get PDF
    Background: Meteorological conditions and air pollution in urban environments have been associated with general population and elderly mortality, showing seasonal variation. Objectives: This study is designed to evaluate the relationship between apparent temperature (AT) and air pollution (PM2.5) vs. mortality in elderly population of Metro Vancouver. Methods: Statistical analyses are performed on moving sum daily mortality rates vs. moving average AT and PM 2.5 in 1-, 2-, 3-, 5-, and 7-day models for all seasons, warm temperatures above 15uC, and cold temperatures below 10uC. Results: Approximately 37 % of the variation in all-season mortality from circulatory and respiratory causes can be explained by the variation in 7-day moving average apparent temperature (r 2 = 0.37, p,0.001). Although the analytical results from air pollution models show increasingly better prediction ability of longer time-intervals (r 2 = 0.012, p,0.001 in a 7-day model), a very weak negative association between elderly mortality and air pollution is observed. Conclusions: Apparent temperature is associated with mortality from respiratory and circulatory causes in elderly population of Metro Vancouver. In a changing climate, one may anticipate to observe potential health impacts from the projected high- and particularly from the low-temperature extremes

    Optoelectronic Capillary Sensors in Microfluidic and Point-of-Care Instrumentation

    Get PDF
    This paper presents a review, based on the published literature and on the authors’ own research, of the current state of the art of fiber-optic capillary sensors and related instrumentation as well as their applications, with special emphasis on point-of-care chemical and biochemical sensors, systematizing the various types of sensors from the point of view of the principles of their construction and operation. Unlike classical fiber-optic sensors which rely on changes in light propagation inside the fiber as affected by outside conditions, optical capillary sensors rely on changes of light transmission in capillaries filled with the analyzed liquid, which opens the possibility of interesting new applications, while raising specific issues relating to the construction, materials and instrumentation of those sensors
    corecore