3,254 research outputs found
Recommended from our members
MOL620: a machine oriented language and language compiler for the varian data 620/l
Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources
We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the
Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities
>100 mJy at 500 μm, but are not visible in existing optical imaging. We fit light profiles to each component of
the lensing systems in Spitzer IRAC 3.6 and 4.5 μm data and successfully disentangle the foreground lens from
the background source in each case, providing important constraints on the spectral energy distributions (SEDs)
of the background SMG at rest-frame optical–near-infrared wavelengths. The SED fits show that these two SMGs
have high dust obscuration with A_V ~ 4–5 and star formation rates of ~100M_⊙ yr^(−1). They have low gas fractions
and low dynamical masses compared with 850 μm selected galaxies
Interprofessional learning at work: What spatial theory can tell us about workplace learning in an acute care ward
It is widely recognized that every workplace potentially provides a rich source of learning. Studies focusing on health care contexts have shown that social interaction within and between professions is crucial in enabling professionals to learn through work, address problems and cope with challenges of clinical practice. While hospital environments are beginning to be understood in spatial terms, the links between space and interprofessional learning at work have not been explored. This paper draws on Lefebvre's tri-partite theoretical framework of perceived, conceived and lived space to enrich understandings of interprofessional learning on an acute care ward in an Australian teaching hospital. Qualitative analysis was undertaken using data from observations of Registered Nurses at work and semi-structured interviews linked to observed events. The paper focuses on a ward round, the medical workroom and the Registrar's room, comparing and contrasting the intended (conceived), practiced (perceived) and pedagogically experienced (lived) spatial dimensions. The paper concludes that spatial theory has much to offer understandings of interprofessional learning in work, and the features of work environments and daily practices that produce spaces that enable or constrain learning. © 2014 Informa UK Ltd
The Herschel SPIRE Fourier Transform Spectrometer Spectral Feature Finder II. Estimating Radial Velocity of SPIRE Spectral Observation Sources
The Herschel SPIRE FTS Spectral Feature Finder (FF) detects significant
spectral features within SPIRE spectra and employs two routines, and external
references, to estimate source radial velocity. The first routine is based on
the identification of rotational CO emission, the second cross-correlates
detected features with a line template containing most of the characteristic
lines in typical far infra-red observations. In this paper, we outline and
validate these routines, summarise the results as they pertain to the FF, and
comment on how external references were incorporated.Comment: 12 pages, 16 figures, 1 table, accepted by MNRAS March 202
Experiences of diagnosis, stigma, culpability, and disclosure in male patients with hepatitis C virus: an interpretative phenomenological analysis
The current study aimed to explore the lived experience of patients with hepatitis C virus infection. Semi-structured interviews were conducted with seven male participants living with hepatitis C virus and were analysed using interpretative phenomenological analysis. Two master themes were identified: (1) diagnosis and the search for meaning and (2) impact of stigma on disclosure. Participants reported fears of contaminating others, feelings of stigma and concerns of disclosing the condition to others. Response to diagnosis, stigma and disclosure among the participants appeared to be interrelated and directly related to locus of blame for virus contraction. More specifically, hepatitis C virus transmission via medical routes led to an externalisation of culpability and an openness to disclosure. Transmission of hepatitis C virus as a direct result of intravenous drug use led to internalised blame and a fear of disclosure. The inter- and intra-personal consequences of hepatitis C virus explored in the current study have potential implications for tailoring future psychological therapy and psychoeducation to the specific needs of the hepatitis C virus population
Leading and Managing the 21st Century Research University: Creating, Implementing, and Sustaining Strategic Change
Universities are competing in an environment in which only the most adaptable to sustainable change will prosper. In order to evolve in this challenging time, universities must embrace strategies for transformational change. This paper reviews two case studies that illustrate the universal applicability of theories of Change Science for achieving sustainable change in stressful times of prosperity and austerity. Understanding the phases of the Change Process that include Creating Vision, Implementing Vision, and Sustaining Vision can promote sustainable change directly related to the culture and mission of the institution
Systematic characterisation of the Herschel SPIRE Fourier Transform Spectrometer
A systematic programme of calibration observations was carried out to monitor
the performance of the SPIRE FTS instrument on board the Herschel Space
Observatory. Observations of planets (including the prime point-source
calibrator, Uranus), asteroids, line sources, dark sky, and cross-calibration
sources were made in order to monitor repeatability and sensitivity, and to
improve FTS calibration. We present a complete analysis of the full set of
calibration observations and use them to assess the performance of the FTS.
Particular care is taken to understand and separate out the effect of pointing
uncertainties, including the position of the internal beam steering mirror for
sparse observations in the early part of the mission. The repeatability of
spectral line centre positions is <5km/s, for lines with signal-to-noise ratios
>40, corresponding to <0.5-2.0% of a resolution element. For spectral line
flux, the repeatability is better than 6%, which improves to 1-2% for spectra
corrected for pointing offsets. The continuum repeatability is 4.4% for the SLW
band and 13.6% for the SSW band, which reduces to ~1% once the data have been
corrected for pointing offsets. Observations of dark sky were used to assess
the sensitivity and the systematic offset in the continuum, both of which were
found to be consistent across the FTS detector arrays. The average point-source
calibrated sensitivity for the centre detectors is 0.20 and 0.21 Jy [1 sigma; 1
hour], for SLW and SSW. The average continuum offset is 0.40 Jy for the SLW
band and 0.28 Jy for the SSW band.Comment: 41 pages, 37 figures, 32 tables. Accepted for publication in MNRA
A novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS)
Sputtering magnetic materials with magnetron based systems has the disadvantage of field quenching and variation of alloy composition with target erosion. The advantage of eliminating magnetic fields in the chamber is that this enables sputtered particles to move along the electric field more uniformly. Inductively coupled impulse sputtering (ICIS) is a form of high power impulse magnetron sputtering (HIPIMS) without a magnetic field where a high density plasma is produced by a high power radio frequency (RF) coil in order to sputter the target and ionise the metal vapour. In this emerging technology, the effects of power and pressure on the ionisation and deposition process are not known. The setup comprises of a 13.56 MHz pulsed RF coil pulsed with a duty cycle of 25 %. A pulsed DC voltage of 1900 V was applied to the cathode to attract Argon ions and initiate sputtering. Optical emission spectra (OES) for Cu and Ti neutrals and ions at constant pressure show a linear intensity increase for peak RF powers of 500 W – 3400 W and a steep drop of intensity for a power of 4500 W. Argon neutrals show a linear increase for powers of 500 W – 2300 W and a saturation of intensity between 2300 W – 4500 W. The influence of pressure on the process was studied at a constant peak RF power of 2300 W. With increasing pressure the ionisation degree increased. The microstructure of the coatings shows globular growth at 2.95×10−2 mbar and large-grain columnar growth at 1.2×10−1 mbar. Bottom coverage of unbiased vias with a width of 0.360 μm and aspect ratio of 2.5:1 increased from 15 % to 20 % for this pressure range. The current work has shown that the concept of combining a RF powered coil with a magnet-free high voltage pulsed DC powered cathode is feasible and produces very stable plasma. The experiments have shown a significant influence of power and pressure on the plasma and coating microstructure
The Identification and Synthesis of Lead Apatite Minerals Formed in Lead Water Pipes
Phosphate is added to drinking water in the UK to minimise the release of lead from lead water pipes. The phosphate encourages the formation of insoluble lead apatites on the walls of the pipe. Hydroxylpyromorphite Pb5(PO4)3OH is the lead apatite that is most often used to model lead levels in tap water; however, its presence has not been confirmed. Our aims were to identify the lead pipe apatite and synthesise it. The synthetic mineral would then be used in future solubility studies to produce better predictions of lead levels in tap water. XRD and FTIR were used to characterise the minerals on a range of lead pipes. Pyromorphite and hydroxylpyromorphite were absent and instead a range of mixed calcium lead apatites were present. For every five lead ions in the general formula Pb5(PO4)3X between one and two ions were replaced with calcium and there was evidence of substitution of  by either  or . Calcium lead apatites with similar unit cell dimensions to those found on lead water pipes were then synthesised. The calcium : lead ratio in these reaction mixtures was in excess of 500 : 1 and the resulting crystals were shown by TEM to be nanosized rods and flakes. The synthetic apatites that most closely resembled the unit cell dimensions of the apatites on lead water pipes were shown to be Pb3.4Ca1.3(PO4)3Cl0.03OH0.97, Pb3.6Ca1.2(PO4)3Cl0.07OH0.93, and Pb3.6Ca1.2(PO4)3Cl0.27OH0.73
- …
