75 research outputs found
Gas phase synthesis and adsorption properties of a 3D ZIF-8 CNT composite
The metal organic framework structure ZIF-8 has been grown directly on vertically aligned carbon nano tubes (VACNT) by a solid vapour transformation of a ZnO@VACNT composite with gaseous 2-methylimidazole. The ZnO@VACNT composite was synthesised by atomic layer deposition (ALD) using diethylzinc and water as precursors resulting in a homogeneous distribution of crystalline ZnO particles with an average size of 13 nm within the 3D VACNT host structure. The ZnO@VACNT composite was transformed to ZIF-8 by reaction with 2-methyl-imidazole (Hmim) while maintaining the 3D VACNT structure employing a solid vapour transformation reaction. Reaction time and temperature were identified as key parameters to control the generated surface area and the degree of conversion of the nanoscaled ZnO particles. 80 °C and 72 h were found to be sufficient for a complete conversion while longer reaction times result in even higher surface areas of the formed ZIF-8@VACNT composite. Surface areas of up to 1569 m g could be achieved. Temperatures below 80 °C led to an incomplete conversion even under longer reaction times of up to 6 weeks. Finally, the CO adsorption properties of the ZIF-8@VACNT composite were evaluated. A composite with a 27 w% content of CNTs and a surface area of 1277 m g shows an adsorption of 6.05 mmol g CO at 30 bar. From the comparison with the pristine materials ZIF-8 and VACNT alone the observed overall CO adsorption behaviour of the composite is a combination of the behaviour of the individual components, ZIF-8 and VACNTs. Namely the typical steep rise of the ZIF-8 in the low-pressure regime with a nearly linear steady progression in the medium pressure size regime, the latter typical for VACNTs, proves that the combination of both components leads to enhanced adsorption properties of the ZIF-8@VACNT composite compared to the sole components ZIF-8 and VACNTs
Comparison of real-time reverse transcriptase polymerase chain reaction of peripheral blood mononuclear cells, serum and cell-free body cavity effusion for the diagnosis of feline infectious peritonitis
Objectives Diagnosis of feline infectious peritonitis (FIP) remains challenging, especially in cats without effusions. The objective of this study was to evaluate the sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (RT-PCR) detecting feline coronavirus (FCoV) RNA in peripheral blood mononuclear cells (PBMCs) and serum in comparison with the same real-time RT-PCR in cell-free body cavity effusion. Methods This prospective case-control study included 92 cats. Forty-three cats had a definitive diagnosis of FIP, established either by histopathological examination (n = 28) or by positive immunofluorescence staining of FCoV antigen in macrophages of effusions (n = 11), or by both methods (n = 4). Forty-nine control cats had other diseases but similar clinical signs. Real-time RT-PCR was performed on PBMCs of 37 cats (21 cats with FIP, 16 controls), on serum of 51 cats (26 cats with FIP, 25 controls) and on cell-free body cavity effusion of 69 cats (36 cats with FIP, 33 controls). Sensitivity, specificity, positive and negative predictive value, including 95% confidence intervals (CI), were calculated. Results Real-time RT-PCR of PBMCs, serum and cell-free body cavity effusion showed a specificity of 100% (95% CI 79.4-100% in PBMCs, 86.3-100% in serum, 89.4-100% in cell-free body cavity effusion) and a sensitivity of 28.6% (95% CI 11.3-52.2%) in PBMCs, 15.4% (95% CI 4.4-34.9%) in serum and 88.9% (95% CI 73.9-96.9%) in cell-free body cavity effusion to diagnose FIP. Conclusions and relevance Although it is known that RT-PCR can often provide false-positive results in healthy cats, this real-time RT-PCR was shown to be a specific tool for the diagnosis of FIP when applied in a clinical setting. Sensitivity in cell-free body cavity effusion was high but low in PBMCs and serum. PBMC samples showed a higher sensitivity than serum samples, and are therefore a better choice if no effusion is present
Interplay Between Risk Perception, Behavior, and COVID-19 Spread
Pharmaceutical and non-pharmaceutical interventions (NPIs) have been crucial for controlling COVID-19. They are complemented by voluntary health-protective behavior, building a complex interplay between risk perception, behavior, and disease spread. We studied how voluntary health-protective behavior and vaccination willingness impact the long-term dynamics. We analyzed how different levels of mandatory NPIs determine how individuals use their leeway for voluntary actions. If mandatory NPIs are too weak, COVID-19 incidence will surge, implying high morbidity and mortality before individuals react; if they are too strong, one expects a rebound wave once restrictions are lifted, challenging the transition to endemicity. Conversely, moderate mandatory NPIs give individuals time and room to adapt their level of caution, mitigating disease spread effectively. When complemented with high vaccination rates, this also offers a robust way to limit the impacts of the Omicron variant of concern. Altogether, our work highlights the importance of appropriate mandatory NPIs to maximise the impact of individual voluntary actions in pandemic control
Field transformations and simple models illustrating the impossibility of measuring off-shell effects
In the context of simple models illustrating field transformations in
Lagrangian field theories we discuss the impossibility of measuring off-shell
effects in nucleon-nucleon bremsstrahlung, Compton scattering, and related
processes. To that end we introduce a simple phenomenological Lagrangian
describing nucleon-nucleon bremsstrahlung and perform an appropriate change of
variables leading to different off-shell behavior in the nucleon-nucleon
amplitude as well as the photon-nucleon vertex. As a result we obtain a class
of equivalent Lagrangians, generating identical S-matrix elements, of which the
original Lagrangian is but one representative. We make use of this property in
order to show that what appears as an off-shell effect in an S-matrix element
for one Lagrangian may originate in a contact term from an equivalent
Lagrangian. By explicit calculation we demonstrate for the case of
nucleon-nucleon bremsstrahlung as well as nucleon Compton scattering the
equivalence of observables from which we conclude that off-shell effects cannot
in any unambiguous way be extracted from an S-matrix element. Finally, we also
discuss some implications of introducing off-shell effects on a
phenomenological basis, resulting from the requirement that the description of
one process be consistent with that of other processes described by the same
Lagrangian.Comment: 19 pages, Latex, using RevTe
A versatile method for simulating pp -> ppe+e- and dp -> pne+e-p_spec reactions
We have developed a versatile software package for the simulation of
di-electron production in and collisions at SIS energies. Particular
attention has been paid to incorporate different descriptions of the Dalitz
decay via a common interface. In addition, suitable
parameterizations for the virtual bremsstrahlung process
based on one-boson exchange models have been implemented. Such simulation tools
with high flexibility of the framework are important for the interpretation of
the di-electron data taken with the HADES spectrometer and the design of
forthcoming experiments
Consistent off-shell vertex and nucleon self-energy
We present a consistent calculation of half-off-shell form factors in the
pion-nucleon vertex and the nucleon self-energy. Numerical results are
presented. Near the on-shell point the pion-nucleon vertex is dominated by the
pseudovector coupling, while at large nucleon invariant masses we find a
sizable pseudoscalar admixture.Comment: 23 pages, 7 figures, REVTeX, submitted to Phys. Rev. C, replaced with
corrected versio
Investigation on the Behavior of Austenite and Ferrite Phases at Stagnation Region in the Turning of Duplex Stainless Steel Alloys
This paper investigates the deformation mechanisms and plastic behavior of austenite and ferrite phases in duplex stainless steel alloys 2205 and 2507 under chip formation from a machine turning operation. SEM images and EBSD phase mapping of frozen chip root samples detected a build-up of ferrite bands in the stagnation region, and between 65 and 85 pct, more ferrite was identified in the stagnation region compared to austenite. SEM images detected micro-cracks developing in the ferrite phase, indicating ferritic build-up in the stagnation region as a potential triggering mechanism to the formation of built-up edge, as transgranular micro-cracks found in the stagnation region are similar to micro-cracks initiating built-up edge formation. Higher plasticity of austenite due to softening under high strain is seen responsible for the ferrite build-up. Flow lines indicate that austenite is plastically deforming at a greater rate into the chip, while ferrite shows to partition most of the strain during deformation. The loss of annealing twins and activation of multiple slip planes triggered at high strain may explain the highly plastic behavior shown by austenite
A new MRI rating scale for progressive supranuclear palsy and multiple system atrophy: validity and reliability
AIM
To evaluate a standardised MRI acquisition protocol and a new image rating scale for disease severity in patients with progressive supranuclear palsy (PSP) and multiple systems atrophy (MSA) in a large multicentre study.
METHODS
The MRI protocol consisted of two-dimensional sagittal and axial T1, axial PD, and axial and coronal T2 weighted acquisitions. The 32 item ordinal scale evaluated abnormalities within the basal ganglia and posterior fossa, blind to diagnosis. Among 760 patients in the study population (PSP = 362, MSA = 398), 627 had per protocol images (PSP = 297, MSA = 330). Intra-rater (n = 60) and inter-rater (n = 555) reliability were assessed through Cohen's statistic, and scale structure through principal component analysis (PCA) (n = 441). Internal consistency and reliability were checked. Discriminant and predictive validity of extracted factors and total scores were tested for disease severity as per clinical diagnosis.
RESULTS
Intra-rater and inter-rater reliability were acceptable for 25 (78%) of the items scored (≥ 0.41). PCA revealed four meaningful clusters of covarying parameters (factor (F) F1: brainstem and cerebellum; F2: midbrain; F3: putamen; F4: other basal ganglia) with good to excellent internal consistency (Cronbach α 0.75-0.93) and moderate to excellent reliability (intraclass coefficient: F1: 0.92; F2: 0.79; F3: 0.71; F4: 0.49). The total score significantly discriminated for disease severity or diagnosis; factorial scores differentially discriminated for disease severity according to diagnosis (PSP: F1-F2; MSA: F2-F3). The total score was significantly related to survival in PSP (p<0.0007) or MSA (p<0.0005), indicating good predictive validity.
CONCLUSIONS
The scale is suitable for use in the context of multicentre studies and can reliably and consistently measure MRI abnormalities in PSP and MSA. Clinical Trial Registration Number The study protocol was filed in the open clinical trial registry (http://www.clinicaltrials.gov) with ID No NCT00211224
- …