142 research outputs found

    Influence of the length of hospitalisation in post-discharge outcomes in patients with acute heart failure: Results of the LOHRCA study

    Get PDF
    Objective: To investigate the relationship between length of hospitalisation (LOH) and post-discharge outcomes in acute heart failure (AHF) patients and to ascertain whether there are different patterns according to department of initial hospitalisation. Methods: Consecutive AHF patients hospitalised in 41 Spanish centres were grouped based on the LOH (15 days). Outcomes were defined as 90-day post-discharge all-cause mortality, AHF readmissions, and the combination of both. Hazard ratios (HRs), adjusted by chronic conditions and severity of decompensation, were calculated for groups with LOH >6 days vs. LOH <6 days (reference), and stratified by hospitalisation in cardiology, internal medicine, geriatrics, or short-stay units. Results: We included 8563 patients (mean age: 80 (SD = 10) years, 55.5% women), with a median LOH of 7 days (IQR 4–11): 2934 (34.3%) had a LOH 15 days. The 90-day post-discharge mortality was 11.4%, readmission 32.2%, and combined endpoint 37.4%. Mortality was increased by 36.5% (95%CI = 13.0–64.9) when LOH was 11–15 days, and by 72.0% (95%CI = 42.6–107.5) when >15 days. Conversely, no differences were found in readmission risk, and the combined endpoint only increased 21.6% (95%CI = 8.4–36.4) for LOH >15 days. Stratified analysis by hospitalisation departments rendered similar post-discharge outcomes, with all exhibiting increased mortality for LOH >15 days and no significant increments in readmission risk. Conclusions: Short hospitalisations are not associated with worse outcomes. While post-discharge readmissions are not affected by LOH, mortality risk increases as the LOH lengthens. These findings were similar across hospitalisation departments

    Effectiveness of an mHealth intervention combining a smartphone app and smart band on body composition in an overweight and obese population: Randomized controlled trial (EVIDENT 3 study)

    Get PDF
    Background: Mobile health (mHealth) is currently among the supporting elements that may contribute to an improvement in health markers by helping people adopt healthier lifestyles. mHealth interventions have been widely reported to achieve greater weight loss than other approaches, but their effect on body composition remains unclear. Objective: This study aimed to assess the short-term (3 months) effectiveness of a mobile app and a smart band for losing weight and changing body composition in sedentary Spanish adults who are overweight or obese. Methods: A randomized controlled, multicenter clinical trial was conducted involving the participation of 440 subjects from primary care centers, with 231 subjects in the intervention group (IG; counselling with smartphone app and smart band) and 209 in the control group (CG; counselling only). Both groups were counselled about healthy diet and physical activity. For the 3-month intervention period, the IG was trained to use a smartphone app that involved self-monitoring and tailored feedback, as well as a smart band that recorded daily physical activity (Mi Band 2, Xiaomi). Body composition was measured using the InBody 230 bioimpedance device (InBody Co., Ltd), and physical activity was measured using the International Physical Activity Questionnaire. Results: The mHealth intervention produced a greater loss of body weight (–1.97 kg, 95% CI –2.39 to –1.54) relative to standard counselling at 3 months (–1.13 kg, 95% CI –1.56 to –0.69). Comparing groups, the IG achieved a weight loss of 0.84 kg more than the CG at 3 months. The IG showed a decrease in body fat mass (BFM; –1.84 kg, 95% CI –2.48 to –1.20), percentage of body fat (PBF; –1.22%, 95% CI –1.82% to 0.62%), and BMI (–0.77 kg/m2, 95% CI –0.96 to 0.57). No significant changes were observed in any of these parameters in men; among women, there was a significant decrease in BMI in the IG compared with the CG. When subjects were grouped according to baseline BMI, the overweight group experienced a change in BFM of –1.18 kg (95% CI –2.30 to –0.06) and BMI of –0.47 kg/m2 (95% CI –0.80 to –0.13), whereas the obese group only experienced a change in BMI of –0.53 kg/m2 (95% CI –0.86 to –0.19). When the data were analyzed according to physical activity, the moderate-vigorous physical activity group showed significant changes in BFM of –1.03 kg (95% CI –1.74 to –0.33), PBF of –0.76% (95% CI –1.32% to –0.20%), and BMI of –0.5 kg/m2 (95% CI –0.83 to –0.19). Conclusions: The results from this multicenter, randomized controlled clinical trial study show that compared with standard counselling alone, adding a self-reported app and a smart band obtained beneficial results in terms of weight loss and a reduction in BFM and PBF in female subjects with a BMI less than 30 kg/m2 and a moderate-vigorous physical activity level. Nevertheless, further studies are needed to ensure that this profile benefits more than others from this intervention and to investigate modifications of this intervention to achieve a global effect

    Registro Español de Trasplante Cardiaco. XXXI Informe Oficial de la Asociación de Insuficiencia Cardiaca de la Sociedad Española de Cardiología

    Get PDF
    IntroducciĂłn y objetivos Se presentan las caracterĂ­sticas clĂ­nicas y los resultados de los trasplantes cardiacos realizados en España con la actualizaciĂłn correspondiente a 2019. MĂ©todos Se describen las caracterĂ­sticas clĂ­nicas y los resultados de los trasplantes cardiacos realizados en 2019, asĂ­ como las tendencias de estos en el periodo 2010-2018. Resultados En 2019 se realizaron 300 trasplantes (8.794 desde 1984; 2.745 entre 2010 y 2019). Respecto a años previos, los cambios mĂĄs llamativos son el descenso hasta el 38% de los trasplantes realizados en cĂłdigo urgente, y la consolidaciĂłn en el cambio de asistencia circulatoria pretrasplante, con la prĂĄctica desapariciĂłn del balĂłn de contrapulsaciĂłn (0, 7%), la estabilizaciĂłn del uso del oxigenador extracorpĂłreo de membrana (9, 6%) y el aumento de los dispositivos de asistencia ventricular (29%). La supervivencia en el trienio 2016-2018 es similar a la del trienio 2013-2015 (p = 0, 34), y ambas mejores que la del trienio 2010-2012 (p = 0, 002 y p = 0, 01 respectivamente). Conclusiones Se mantienen estables tanto la actividad del trasplante cardiaco en España como los resultados en supervivencia en los Ășltimos 2 trienios. Hay una tendencia a realizar menos trasplantes urgentes, la mayorĂ­a con dispositivos de asistencia ventricular. Introduction and objectives: The present report describes the clinical characteristics and outcomes of heart transplants in Spain and updates the data to 2019. Methods: We describe the clinical characteristics and outcomes of heart transplants performed in Spain in 2019, as well as trends in this procedure from 2010 to 2018. Results: In 2019, 300 transplants were performed (8794 since 1984; 2745 between 2010 and 2019). Compared with previous years, the most notable findings were the decreasing rate of urgent transplants (38%), and the consolidation of the type of circulatory support prior to transplant, with an almost complete disappearance of counterpulsation balloon (0.7%), stabilization in the use of extracorporeal membrane oxygenation (9.6%), and an increase in the use of ventricular assist devices (29.0%). Survival from 2016 to 2018 was similar to that from 2013 to 2015 (P = .34). Survival in both these periods was better than that from 2010 to 2012 (P = .002 and P = .01, respectively). Conclusions: Heart transplant activity has remained stable during the last few years, as have outcomes (in terms of survival). There has been a trend to a lower rate of urgent transplants and to a higher use of ventricular assist devices prior to transplant

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la GuĂ­a española para el manejo del asma (GEMA 2009 y 2015) y su repercusiĂłn en el control de la enfermedad. Material y mĂ©todos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 mĂ©dicos de atenciĂłn primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 mĂ©dicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 mĂ©dicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguĂ­an las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asociĂł de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guĂ­as clĂ­nicas para el manejo del asma constituye un problema comĂșn entre los mĂ©dicos de atenciĂłn primaria. Un seguimiento de estas guĂ­as se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los mĂ©dicos de atenciĂłn primaria de las guĂ­as para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (GuĂ­a Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Search for boosted diphoton resonances in the 10 to 70 GeV mass range using 138 fb−1 of 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for diphoton resonances in the mass range between 10 and 70 GeV with the ATLAS experiment at the Large Hadron Collider (LHC) is presented. The analysis is based on pp collision data corresponding to an integrated luminosity of 138 fb−1 at a centre-of-mass energy of 13 TeV recorded from 2015 to 2018. Previous searches for diphoton resonances at the LHC have explored masses down to 65 GeV, finding no evidence of new particles. This search exploits the particular kinematics of events with pairs of closely spaced photons reconstructed in the detector, allowing examination of invariant masses down to 10 GeV. The presented strategy covers a region previously unexplored at hadron colliders because of the experimental challenges of recording low-energy photons and estimating the backgrounds. No significant excess is observed and the reported limits provide the strongest bound on promptly decaying axion-like particles coupling to gluons and photons for masses between 10 and 70 GeV

    Evidence for the charge asymmetry in pp → tt¯ production at s√ = 13 TeV with the ATLAS detector

    Get PDF
    Inclusive and differential measurements of the top–antitop (ttÂŻ) charge asymmetry AttÂŻC and the leptonic asymmetry Aℓℓ¯C are presented in proton–proton collisions at s√ = 13 TeV recorded by the ATLAS experiment at the CERN Large Hadron Collider. The measurement uses the complete Run 2 dataset, corresponding to an integrated luminosity of 139 fb−1, combines data in the single-lepton and dilepton channels, and employs reconstruction techniques adapted to both the resolved and boosted topologies. A Bayesian unfolding procedure is performed to correct for detector resolution and acceptance effects. The combined inclusive ttÂŻ charge asymmetry is measured to be AttÂŻC = 0.0068 ± 0.0015, which differs from zero by 4.7 standard deviations. Differential measurements are performed as a function of the invariant mass, transverse momentum and longitudinal boost of the ttÂŻ system. Both the inclusive and differential measurements are found to be compatible with the Standard Model predictions, at next-to-next-to-leading order in quantum chromodynamics perturbation theory with next-to-leading-order electroweak corrections. The measurements are interpreted in the framework of the Standard Model effective field theory, placing competitive bounds on several Wilson coefficients

    Search for heavy resonances decaying into a Z or W boson and a Higgs boson in final states with leptons and b-jets in 139 fb−1 of pp collisions at s√ = 13 TeV with the ATLAS detector

    Get PDF
    This article presents a search for new resonances decaying into a Z or W boson and a 125 GeV Higgs boson h, and it targets the ÎœÎœÂŻÂŻÂŻbbÂŻÂŻ, ℓ+ℓ−bbÂŻÂŻ, or ℓ±ΜbbÂŻÂŻ final states, where ℓ = e or ÎŒ, in proton-proton collisions at s√ = 13 TeV. The data used correspond to a total integrated luminosity of 139 fb−1 collected by the ATLAS detector during Run 2 of the LHC at CERN. The search is conducted by examining the reconstructed invariant or transverse mass distributions of Zh or Wh candidates for evidence of a localised excess in the mass range from 220 GeV to 5 TeV. No significant excess is observed and 95% confidence-level upper limits between 1.3 pb and 0.3 fb are placed on the production cross section times branching fraction of neutral and charged spin-1 resonances and CP-odd scalar bosons. These limits are converted into constraints on the parameter space of the Heavy Vector Triplet model and the two-Higgs-doublet model

    Inclusive-photon production and its dependence on photon isolation in pp collisions at s√ = 13 TeV using 139 fb−1 of ATLAS data

    Get PDF
    Measurements of differential cross sections are presented for inclusive isolated-photon production in pp collisions at a centre-of-mass energy of 13 TeV provided by the LHC and using 139 fb−1 of data recorded by the ATLAS experiment. The cross sections are measured as functions of the photon transverse energy in different regions of photon pseudorapidity. The photons are required to be isolated by means of a fixed-cone method with two different cone radii. The dependence of the inclusive-photon production on the photon isolation is investigated by measuring the fiducial cross sections as functions of the isolation-cone radius and the ratios of the differential cross sections with different radii in different regions of photon pseudorapidity. The results presented in this paper constitute an improvement with respect to those published by ATLAS earlier: the measurements are provided for different isolation radii and with a more granular segmentation in photon pseudorapidity that can be exploited in improving the determination of the proton parton distribution functions. These improvements provide a more in-depth test of the theoretical predictions. Next-to-leading-order QCD predictions from JETPHOX and SHERPA and next-to-next-to-leading-order QCD predictions from NNLOJET are compared to the measurements, using several parameterisations of the proton parton distribution functions. The measured cross sections are well described by the fixed-order QCD predictions within the experimental and theoretical uncertainties in most of the investigated phase-space region
    • 

    corecore