36 research outputs found

    AQP4-IgG-seronegative patient outcomes in the N-MOmentum trial of inebilizumab in neuromyelitis optica spectrum disorder

    Get PDF
    BACKGROUND: The N-MOmentum trial, a double-blind, randomized, placebo-controlled, phase 2/3 study of inebilizumab in neuromyelitis optica spectrum disorder (NMOSD), enrolled participants who were aquaporin-4-immunoglobulin G (AQP4-IgG)-seropositive (AQP4+) or -seronegative (AQP4−). This manuscript reports AQP4− participant outcomes. METHODS: AQP4-IgG serostatus was determined for all screened participants by a central laboratory, using a validated, fluorescence-observation cell-binding assay. Medical histories and screening data for AQP4− participants were assessed independently by an eligibility committee of three clinical experts during screening. Diagnosis of NMOSD was confirmed by majority decision using the 2006 neuromyelitis optica criteria. Myelin oligodendrocyte glycoprotein-immunoglobulin G (MOG-IgG) serology (using a clinically validated, flow cytometry assay) and annualized attack rates (AARs) were evaluated post hoc. Efficacy outcomes were assessed by comparing pre-study and on-study AARs in treated participants. RESULTS: Only 18/50 AQP4− screened participants (36%) were initially considered eligible for randomization; 16 were randomized and received full treatment, 4 to placebo (1 MOG-IgG-seropositive [MOG+]) and 12 to inebilizumab (6 MOG+). The most common reason for failure to pass screening among prospective AQP4− participants was failure to fulfill the 2006 NMO MRI criteria. In inebilizumab-treated AQP4− participants, on-study AARs (95% confidence interval [CI]) calculated from treatment initiation (whether from randomization or when received at the start of the open-label period) to the end of study were lower than pre-study rates: for all AQP4− participants (n = 16), mean (95% CI) AAR was 0.048 (0.02–0.15) versus 1.70 (0.74–2.66), respectively. For the subset of AQP4−/MOG+ participants (n = 7), AAR was 0.043 (0.006–0.302) after treatment versus 1.93 (1.10–3.14) before the study. For the subset of AQP4−/MOG− participants (n = 9), post-treatment AAR was 0.051 (0.013–0.204) versus 1.60 (1.02–2.38). Three attacks occurred during the randomized controlled period in the AQP4− inebilizumab group and were of mild severity; no attacks occurred in the AQP4− placebo group. The low number of participants receiving placebo (n = 4) confounds direct comparison with the inebilizumab group. No attacks were seen in any AQP4− participant after the second infusion of inebilizumab. Inebilizumab was generally well tolerated by AQP4− participants and the adverse event profile observed was similar to that of AQP4+ participants. CONCLUSION: The high rate of rejection of AQP4− participants from enrollment into the study highlights the challenges of implementing the diagnostic criteria of AQP4− NMOSD. An apparent reduction of AAR in participants with AQP4− NMOSD who received inebilizumab warrants further investigation

    Disability outcomes in the N-MOmentum trial of inebilizumab in neuromyelitis optica spectrum disorder

    Get PDF
    OBJECTIVE: To assess treatment effects on Expanded Disability Status Scale (EDSS) score worsening and modified Rankin Scale (mRS) scores in the N-MOmentum trial of inebilizumab, a humanized anti-CD19 monoclonal antibody, in participants with neuromyelitis optica spectrum disorder (NMOSD). METHODS: Adults (N = 230) with aquaporin-4 immunoglobulin G-seropositive NMOSD or -seronegative neuromyelitis optica and an EDSS score ≤8 were randomized (3:1) to receive inebilizumab 300 mg or placebo on days 1 and 15. The randomized controlled period (RCP) was 28 weeks or until adjudicated attack, with an option to enter the inebilizumab open-label period. Three-month EDSS-confirmed disability progression (CDP) was assessed using a Cox proportional hazard model. The effect of baseline subgroups on disability was assessed by interaction tests. mRS scores from the RCP were analyzed by the Wilcoxon-Mann-Whitney odds approach. RESULTS: Compared with placebo, inebilizumab reduced the risk of 3-month CDP (hazard ratio [HR]: 0.375; 95% CI: 0.148-0.952; p = 0.0390). Baseline disability, prestudy attack frequency, and disease duration did not affect the treatment effect observed with inebilizumab (HRs: 0.213-0.503; interaction tests: all p > 0.05, indicating no effect of baseline covariates on outcome). Mean EDSS scores improved with longer-term treatment. Inebilizumab-treated participants were more likely to have a favorable mRS outcome at the end of the RCP (OR: 1.663; 95% CI: 1.195-2.385; p = 0.0023). CONCLUSIONS: Disability outcomes were more favorable with inebilizumab vs placebo in participants with NMOSD

    Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment

    Get PDF
    LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4 × 10-48cm2 for a 40 GeV/c2 mass WIMP. Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3 × 10−43 cm2 (7.1 × 10−42 cm2) for a 40 GeV/c2 mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020

    Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study

    Get PDF
    A41 Use of SMS texts for facilitating access to online alcohol interventions: a feasibility study In: Addiction Science & Clinical Practice 2017, 12(Suppl 1): A4

    Search for annual and diurnal rate modulations in the LUX experiment

    Get PDF
    Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth’s motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±0.2  cpd/keVee/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26  keVee. Between 2 and 6  keVee, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2  cpd/keVee/tonne amplitude between 2 and 6  keVee.Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±\pm0.2~cpd/keVee_{\text{ee}}/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keVee_{\text{ee}}. Between 2 and 6~keVee_{\text{ee}}, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ\sigma tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keVee_{\text{ee}}/tonne amplitude between 2 and 6~keVee_{\text{ee}}

    Measurement of the gamma ray background in the Davis Cavern at the Sanford Underground Research Facility

    Get PDF
    Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ-rays emitted by 40K and the 238U and 232Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ γ-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of 1.9±0.4~γ cm−2s−1. The resulting activity in the walls of the cavern can be characterised as 220±60~Bq/kg of 40K, 29±15~Bq/kg of 238U, and 13±3~Bq/kg of 232Th
    corecore