380 research outputs found

    Stratosphere-troposphere separation of nitrogen dioxide columns from the TEMPO geostationary satellite instrument

    Get PDF
    Separating the stratospheric and tropospheric contributions in satellite retrievals of atmospheric NO2 column abundance is a crucial step in the interpretation and application of the satellite observations. A variety of stratosphere–troposphere separation algorithms have been developed for sun-synchronous instruments in low Earth orbit (LEO) that benefit from global coverage, including broad clean regions with negligible tropospheric NO2 compared to stratospheric NO2. These global sun-synchronous algorithms need to be evaluated and refined for forthcoming geostationary instruments focused on continental regions, which lack this global context and require hourly estimates of the stratospheric column. Here we develop and assess a spatial filtering algorithm for the upcoming TEMPO geostationary instrument that will target North America. Developments include using independent satellite observations to identify likely locations of tropospheric enhancements, using independent LEO observations for spatial context, consideration of diurnally varying partial fields of regard, and a filter based on stratospheric to tropospheric air mass factor ratios. We test the algorithm with LEO observations from the OMI instrument with an afternoon overpass, and from the GOME-2 instrument with a morning overpass. We compare our TEMPO field of regard algorithm against an identical global algorithm to investigate the penalty resulting from the limited spatial coverage in geostationary orbit, and find excellent agreement in the estimated mean daily tropospheric NO2 column densities (R2=0.999, slope=1.009 for July and R2=0.998, slope=0.999 for January). The algorithm performs well even when only small parts of the continent are observed by TEMPO. The algorithm is challenged the most by east coast morning retrievals in the wintertime (e.g., R2=0.995, slope=1.038 at 14:00 UTC). We find independent global LEO observations (corrected for time of day) provide important context near the field-of-regard edges. We also test the performance of the TEMPO algorithm without these supporting global observations. Most of the continent is unaffected (R2=0.924 and slope=0.973 for July and R2=0.996 and slope=1.008 for January), with 90 % of the pixels having differences of less than ±0.2×1015 molecules cm−2 between the TEMPO tropospheric NO2 column density and the global algorithm. For near-real-time retrieval, even a climatological estimate of the stratospheric NO2 surrounding the field of regard would improve this agreement. In general, the additional penalty of a limited field of regard from TEMPO introduces no more error than normally expected in most global stratosphere–troposphere separation algorithms. Overall, we conclude that hourly near-real-time stratosphere–troposphere separation for the retrieval of NO2 tropospheric column densities by the TEMPO geostationary instrument is both feasible and robust, regardless of the diurnally varying limited field of regard.The authors are grateful to Kelly Chance, Xiong Liu, John Houck, Peter Zoogman, and other members of the TEMPO trace gas retrieval team for their input in preparation of this paper. Work at Dalhousie University was supported by Environment and Climate Change Canada. The authors also gratefully acknowledge the free use of TEMIS NO2 data from the GOME-2 sensor provided by http://www.temis.nl, last access: 12 November 2018, and the NASA Standard Product NO2 data from OMI provided by https://disc.gsfc.nasa.gov/datasets/OMNO2_V003/summary, last access: 9 November 2018. (Environment and Climate Change Canada)https://www.atmos-meas-tech.net/11/6271/2018/Published versio

    A randomised control trial of the effectiveness of personalised letters sent subsequent to school dental inspections in increasing registration in unregistered children

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent studies have cast doubt on the effectiveness and efficiency of school based dental screening programmes in improving dental attendance or improving dental health. In 2002 the National Dental Inspection Programme was introduced in Scotland which categorises children by their dental health and informs parents of the findings via a personalised letter home and encourages dental registration. In addition, epidemiological data for local and national planning purposes is collected. This replaced an earlier school screening system in Lothian where a generic letter urging registration was sent to children who were identified as not being registered with a dentist. The objective of this study is to compare dental registrations rates among unregistered children in these two school inspection systems with a system where letters were sent home but no dental inspection was carried out.</p> <p>Methods</p> <p>The study was designed as a single blinded, cluster randomised, controlled trial involving 12,765 12–13-year-old children attending all 65 state Secondary schools in Lothian and Fife during the academic year 2003/4.</p> <p>After stratifying for school size and range of social deprivation, schools were randomly allocated to one of four groups:</p> <p>1. 'Traditional' inspection, letter to unregistered children only,</p> <p>2. Letter sent home to unregistered children only, no inspection,</p> <p>3. National Dental Inspection Programme, letter to all children,</p> <p>4. Control group in which the children were neither inspected nor sent a letter.</p> <p>Dental Registration status was compared at baseline and 3 months post inspection.</p> <p>Results</p> <p>The registration levels in both the 'Traditional' screening and the NDIP inspection groups rose 3 months post inspection (14% and 15.8% respectively) but were not significantly different from one another or the control group which rose by 15.8% (p > 0.05). The group who were sent a letter home but were not inspected also has a rise in registration levels of 18.1% which was not significantly different from either of the groups who were inspected or the control group (p > 0.05). The only significant predictors of registration were previous registration (p < 0.05) and within those who previously registered, the length of time since last registration (P < 0.001).</p> <p>Conclusion</p> <p>Neither of the two dental inspection methods nor a letter home to unregistered children resulted in a significant rise in registration rates in 12–13-year-olds compared to a control group of children who received no intervention.</p

    Continuous direct compression as manufacturing platform for sustained release tablets

    Get PDF
    This study presents a framework for process and product development on a continuous direct compression manufacturing platform. A challenging sustained release formulation with high content of a poorly flowing low density drug was selected. Two HPMC grades were evaluated as matrix former: standard Methocel CR and directly compressible Methocel DC2. The feeding behavior of each formulation component was investigated by deriving feed factor profiles. The maximum feed factor was used to estimate the drive command and depended strongly upon the density of the material. Furthermore, the shape of the feed factor profile allowed definition of a customized refill regime for each material. Inline NIRs was used to estimate the residence time distribution (RTD) in the mixer and monitor blend uniformity. Tablet content and weight variability were determined as additional measures of mixing performance. For Methocel CR, the best axial mixing (i.e. feeder fluctuation dampening) was achieved when an impeller with high number of radial mixing blades operated at low speed. However, the variability in tablet weight and content uniformity deteriorated under this condition. One can therefore conclude that balancing axial mixing with tablet quality is critical for Methocel CR. However, reformulating with the direct compressible Methocel DC2 as matrix former improved tablet quality vastly. Furthermore, both process and product were significantly more robust to changes in process and design variables. This observation underpins the importance of flowability during continuous blending and die-filling. At the compaction stage, blends with Methocel CR showed better tabletability driven by a higher compressibility as the smaller CR particles have a higher bonding area. However, tablets of similar strength were achieved using Methocel DC2 by targeting equal porosity. Compaction pressure impacted tablet properties and dissolution. Hence controlling thickness during continuous manufacturing of sustained release tablets was crucial to ensure reproducible dissolution. (C) 2017 Elsevier B.V. All rights reserved

    Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays

    Get PDF
    Single-slope analog-to-digital converters (ADCs) are particularly useful for onchip digitization in focal plane arrays (FPAs) because of their inherent monotonicity, relative simplicity, and efficiency for column-parallel applications, but they are comparatively slow. Squareroot encoding can allow the number of code values to be reduced without loss of signal-to-noise ratio (SNR) by keeping the quantization noise just below the signal shot noise. This encoding can be implemented directly by using a quadratic ramp. The reduction in the number of code values can substantially increase the quantization speed. However, in an FPA, the fixed pattern noise (FPN) limits the use of small quantization steps at low signal levels. If the zero-point is adjusted so that the lowest column is onscale, the other columns, including those at the center of the distribution, will be pushed up the ramp where the quantization noise is higher. Additionally, the finite frequency response of the ramp buffer amplifier and the comparator distort the shape of the ramp, so that the effective ramp value at the time the comparator trips differs from the intended value, resulting in errors. Allowing increased settling time decreases the quantization speed, while increasing the bandwidth increases the noise. The FPN problem is solved by breaking the ramp into two portions, with some fraction of the available code values allocated to a linear ramp and the remainder to a quadratic ramp. To avoid large transients, both the value and the slope of the linear and quadratic portions should be equal where they join. The span of the linear portion must cover the minimum offset, but not necessarily the maximum, since the fraction of the pixels above the upper limit will still be correctly quantized, albeit with increased quantization noise. The required linear span, maximum signal and ratio of quantization noise to shot noise at high signal, along with the continuity requirement, determines the number of code values that must be allocated to each portion. The distortion problem is solved by using a lookup table to convert captured code values back to signal levels. The values in this table will be similar to the intended ramp value, but with a correction for the finite bandwidth effects. Continuous-time comparators are used, and their bandwidth is set below the step rate, which smoothes the ramp and reduces the noise. No settling time is needed, as would be the case for clocked comparators, but the low bandwidth enhances the distortion of the non-linear portion. This is corrected by use of a return lookup table, which differs from the one used to generate the ramp. The return lookup table is obtained by calibrating against a stepped precision DC reference. This results in a residual non-linearity well below the quantization noise. This method can also compensate for differential non-linearity (DNL) in the DAC used to generate the ramp. The use of a ramp with a combination of linear and quadratic portions for a single-slope ADC is novel. The number of steps is minimized by keeping the step size just below the photon shot noise. This in turn maximizes the speed of the conversion. High resolution is maintained by keeping small quantization steps at low signals, and noise is minimized by allowing the lowest analog bandwidth, all without increasing the quantization noise. A calibrated return lookup table allows the system to maintain excellent linearity

    Home-based reach-to-grasp training for people after stroke: study protocol for a feasibility randomized controlled trial

    Get PDF
    BackgroundThis feasibility study is intended to assess the acceptability of home-based task-specific reach-to-grasp (RTG) training for people with stroke, and to gather data to inform recruitment, retention, and sample size for a definitive randomized controlled trial. Methods/designThis is to be a randomized controlled feasibility trial recruiting 50 individuals with upper-limb motor impairment after stroke. Participants will be recruited after discharge from hospital and up to 12 months post-stroke from hospital stroke services and community therapy-provider services. Participants will be assessed at baseline, and then electronically randomized and allocated to group by minimization, based on the time post-stroke and extent of upper-limb impairment. The intervention group will receive 14 training sessions, each 1 hour long, with a physiotherapist over 6 weeks and will be encouraged to practice independently for 1 hour/day to give a total of 56 hours of training time per participant. Participants allocated to the control group will receive arm therapy in accordance with usual care. Participants will be measured at 7 weeks post-randomization, and followed-up at 3 and 6 months post-randomization. Primary outcome measures for assessment of arm function are the Action Research Arm Test (ARAT) and Wolf Motor Function Test (WMFT). Secondary measures are the Motor Activity Log, Stroke Impact Scale, Carer Strain Index, and health and social care resource use. All assessments will be conducted by a trained assessor blinded to treatment allocation. Recruitment, adherence, withdrawals, adverse events (AEs), and completeness of data will be recorded and reported. DiscussionThis study will determine the acceptability of the intervention, the characteristics of the population recruited, recruitment and retention rates, descriptive statistics of outcomes, and incidence of AEs. It will provide the information needed for planning a definitive trial to test home-based RTG training. Trial registrationISRCTN: ISRCTN5671658

    Near-infrared spectroscopy as a tool for marine mammal research and care

    Get PDF
    This project was partially funded by the Department for Business, Energy and Industrial Strategy Offshore Energy Strategic Environmental Assessment Programme. Supplementary funding supporting JM was provided by the US Office of Naval Research (ONR) grant nos. N00014-18-1-2062 and N00014-20-1-2709. Supplementary funding supporting AF and JM was provided by the US Office of Naval Research (ONR) grant no. N00014-19-1-2560. Supplementary funding supporting BS-C, JK, and AR was provided by the US Office of Naval Research (ONR) grant no. N00014-19-1-1223.Developments in wearable human medical and sports health trackers has offered new solutions to challenges encountered by eco-physiologists attempting to measure physiological attributes in freely moving animals. Near-infrared spectroscopy (NIRS) is one such solution that has potential as a powerful physio-logging tool to assess physiology in freely moving animals. NIRS is a non-invasive optics-based technology, that uses non-ionizing radiation to illuminate biological tissue and measures changes in oxygenated and deoxygenated hemoglobin concentrations inside tissues such as skin, muscle, and the brain. The overall footprint of the device is small enough to be deployed in wearable physio-logging devices. We show that changes in hemoglobin concentration can be recorded from bottlenose dolphins and gray seals with signal quality comparable to that achieved in human recordings. We further discuss functionality, benefits, and limitations of NIRS as a standard tool for animal care and wildlife tracking for the marine mammal research community.Publisher PDFPeer reviewe

    Learning, odour preference and flower foraging in moths

    Get PDF
    Floral volatiles play a major role in plant-insect communication. We examined the influence of two volatiles, phenylacetaldehyde and a-pinene, on the innate and learnt foraging behaviour of the moth Helicoverpa armigera. In dual-choice wind tunnel tests, adult moths flew upwind towards both volatiles, with a preference for phenylacetaldehyde. When exposure to either of these volatiles was paired with a feeding stimulus (sucrose), all moths preferred the learnt odour in the preference test. This change in preference was not seen when moths were exposed to the odour without a feeding stimulus. The learnt preference for the odour was reduced when moths were left unfed for 24 h before the preference test. We tested whether moths could discriminate between flowers that differed in a single volatile component. Moths were trained to feed on flowers that were odour-enhanced using either phenylacetaldehyde or a-pinene. Choice tests were then carried out in an outdoor flight cage, using flowers enhanced with either volatile. Moths showed a significant preference for the flower type on which they were trained. Moths that were conditioned on flowers that were not odour-enhanced showed no preference for either of the odour-enhanced flower types. The results imply that moths may be discriminating among odour profiles of individual flowers from the same species. We discuss this behaviour within the context of nectar foraging in moths and odour signalling by flowering plants

    Fast, High-Precision Readout Circuit for Detector Arrays

    Get PDF
    The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 11-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges
    • …
    corecore