20 research outputs found

    Clinical effect of deep water running on non-specific low back pain: A randomised trial

    Get PDF
    Objectives: To evaluate clinical effect of deep water running(DW R) on non-specific low back pain. Outcome measures were pain, disability,general health and physical fitness.  Materials and methods: Experimental, randomized,  controlled trial involving 46 persons with CLBP over 15 weekswith two experimental processes, each three times a week. Evidence-basedProgram (EBP, personalized physical exercise program, manual therapy andhealth educa tion) was the common process to which was added 20 minutes ofpersonalized intensity DW R at the aerobic threshold. Measurements were made at the beginning and end of the studyof pain, disability, general health and physical fitness.  R esults: The pain of CLBP were homogeneous at baseline.Significant changes between group were don’t found for pain in favour of the EBP+DW R group (p<0.3). The within-group differences were highly significant for all clinical and functional variables. The effect was clinically relevant forpain in the EBP+DW R group (0.70) and in the EBP group (0.58), and for disability degree it was also relevant in theEBP+DW R group (0.48) and relevant for the EBP group (0.36). Conclusion: Significant improvement was seen inCLBP when EBP was complemented with the high-intensity exercise of DW R

    Validity and reliability of a sensor based electronic spinal mobility index for Axial Spondyloarthritis

    Get PDF
    Objective: To evaluate the validity and reliability of inertial measurement unit (IMU) sensors in the assessment of spinal mobility in axial Spondyloarthritis (axSpA). Methods: A repeated measures study design involving 40 participants with axSpA was used. Pairs of IMU sensors were used to measure the maximum range of movement at the cervical and lumbar spine. A composite IMU score was defined by combining the IMU measures. Conventional metrology and physical function assessment were performed. Validation was assessed considering the agreement of IMU measures with conventional metrology and correlation with physical function. Reliability was assessed using intra-class correlation coefficients (ICCs). Results: The composite IMU score correlated closely (r=0.88) with the Bath Ankylosing Spondylitis Metrology Index (BASMI). Conventional cervical rotation and lateral flexion tests correlated closely with IMU equivalents (r=0.85,0.84). All IMU movement tests correlated strongly with Bath Ankylosing Spondylitis Functional Index (BASFI) whilst this was true for only some of the BASMI tests. The reliability of both conventional and IMU tests (except for chest expansion) ranged from good to excellent. Test-retest ICCs for individual conventional tests varied between 0.57 and 0.91, in comparison to a range from 0.74 to 0.98 for each of the IMU tests. Each of the composite regional IMU scores had excellent test-retest reliability (ICCs 0.94-0.97), comparable to the reliability of the BASMI (ICC 0.96). Conclusion: Cervical and lumbar spinal mobility measured using wearable IMU sensors is a valid and reliable assessment in multiple planes (including rotation), in patients with a wide range of axSpA severity

    Tools for Evaluating the Content, Efficacy, and Usability of Mobile Health Apps According to the Consensus-Based Standards for the Selection of Health Measurement Instruments: Systematic Review.

    Get PDF
    BACKGROUND: There are several mobile health (mHealth) apps in mobile app stores. These apps enter the business-to-customer market with limited controls. Both, apps that users use autonomously and those designed to be recommended by practitioners require an end-user validation to minimize the risk of using apps that are ineffective or harmful. Prior studies have reviewed the most relevant aspects in a tool designed for assessing mHealth app quality, and different options have been developed for this purpose. However, the psychometric properties of the mHealth quality measurement tools, that is, the validity and reliability of the tools for their purpose, also need to be studied. The Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) initiative has developed tools for selecting the most suitable measurement instrument for health outcomes, and one of the main fields of study was their psychometric properties. OBJECTIVE: This study aims to address and psychometrically analyze, following the COSMIN guideline, the quality of the tools that are used to measure the quality of mHealth apps. METHODS: From February 1, 2019, to December 31, 2019, 2 reviewers searched PubMed and Embase databases, identifying mHealth app quality measurement tools and all the validation studies associated with each of them. For inclusion, the studies had to be meant to validate a tool designed to assess mHealth apps. Studies that used these tools for the assessment of mHealth apps but did not include any psychometric validation were excluded. The measurement tools were analyzed according to the 10 psychometric properties described in the COSMIN guideline. The dimensions and items analyzed in each tool were also analyzed. RESULTS: The initial search showed 3372 articles. Only 10 finally met the inclusion criteria and were chosen for analysis in this review, analyzing 8 measurement tools. Of these tools, 4 validated ≥5 psychometric properties defined in the COSMIN guideline. Although some of the tools only measure the usability dimension, other tools provide information such as engagement, esthetics, or functionality. Furthermore, 2 measurement tools, Mobile App Rating Scale and mHealth Apps Usability Questionnaire, have a user version, as well as a professional version. CONCLUSIONS: The Health Information Technology Usability Evaluation Scale and the Measurement Scales for Perceived Usefulness and Perceived Ease of Use were the most validated tools, but they were very focused on usability. The Mobile App Rating Scale showed a moderate number of validated psychometric properties, measures a significant number of quality dimensions, and has been validated in a large number of mHealth apps, and its use is widespread. It is suggested that the continuation of the validation of this tool in other psychometric properties could provide an appropriate option for evaluating the quality of mHealth apps

    Assessment of the quality of mobile applications (Apps) for management of low back pain using the mobile app rating scale (mars)

    Get PDF
    Digital health interventions may improve different behaviours. However, the rapid proliferation of technological solutions often does not allow for a correct assessment of the quality of the tools. This study aims to review and assess the quality of the available mobile applications (apps) related to interventions for low back pain. Two reviewers search the official stores of Android (Play Store) and iOS (App Store) for localisation in Spain and the United Kingdom, in September 2019, searching for apps related to interventions for low back pain. Seventeen apps finally are included. The quality of the apps is measured using the Mobile App Rating Scale (MARS). The scores of each section and the final score of the apps are retrieved and the mean and standard deviation obtained. The average quality ranges between 2.83 and 4.57 (mean 3.82) on a scale from 1 (inadequate) to 5 (excellent). The best scores are found in functionality (4.7), followed by aesthetic content (mean 4.1). Information (2.93) and engagement (3.58) are the worst rated items. Apps generally have good overall quality, especially in terms of functionality and aesthetics. Engagement and information should be improved in most of the apps. Moreover, scientific evidence is necessary to support the use of applied health tools

    The Validity of the Energy Expenditure Criteria Based on Open Source Code through two Inertial Sensors

    Get PDF
    Through this study, we developed and validated a system for energy expenditure calcula-tion, which only requires low-cost inertial sensors and open source R software. Five healthy subjects ran at ten different speeds while their kinematic variables were recorded on the thigh and wrist. Two ActiGraph wireless inertial sensors and a low-cost Bluetooth-based inertial sensor (Lis2DH12), assembled by SensorID, were used. Ten energy expenditure equations were automatically calculated in a developed open source R software (our own creation). A correlation analysis was used to compare the results of the energy expenditure equations. A high interclass correlation coefficient of estimated energy expenditure on the thigh and wrist was observed with an Actigraph and Sensor ID accelerometer; the corrected Freedson equation showed the highest values, and the Santos-Lozano vector magnitude equation and Sasaki equation demonstrated the lowest one. Energy expenditure was compared between the wrist and thigh and showed low correlation values. Despite the positive results obtained, it was necessary to design specific equations for the estimation of energy expenditure measured with inertial sensors on the thigh. The use of the same formula equation in two different placements did not report a positive interclass correlation coefficient

    Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code

    Get PDF
    The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test consisted of a 1 min walk for participants to become accustomed to the treadmill, followed by a 2 min trial at ten pre-set speeds. Data from both sensors were collected in real-time. Intraclass correlation coefficient (ICC) was used to evaluate the equality of characteristics obtained by both sensors: maximum peaks, minimum peaks, and the mean of the complete signal (sequence of acceleration values along the time) by each axis and speed were extracted to evaluate the equality of characteristics obtained with LIS2DH12 compared to Actigraph. Intraclass correlation coefficient (ICC) was extracted, and a standard deviation of the mean was obtained from the data. Our results show that LIS2DH12 measurements present more reliability than Actigraph GT9X, ICC > 0.8 at three axes. This study concludes that LIS2DH12 is as reliable and accurate as Actigraph GT9X Link and, therefore, would be a suitable tool for future kinematic studies

    New insights into the genetic etiology of Alzheimer's disease and related dementias

    Get PDF
    Characterization of the genetic landscape of Alzheimer's disease (AD) and related dementias (ADD) provides a unique opportunity for a better understanding of the associated pathophysiological processes. We performed a two-stage genome-wide association study totaling 111,326 clinically diagnosed/'proxy' AD cases and 677,663 controls. We found 75 risk loci, of which 42 were new at the time of analysis. Pathway enrichment analyses confirmed the involvement of amyloid/tau pathways and highlighted microglia implication. Gene prioritization in the new loci identified 31 genes that were suggestive of new genetically associated processes, including the tumor necrosis factor alpha pathway through the linear ubiquitin chain assembly complex. We also built a new genetic risk score associated with the risk of future AD/dementia or progression from mild cognitive impairment to AD/dementia. The improvement in prediction led to a 1.6- to 1.9-fold increase in AD risk from the lowest to the highest decile, in addition to effects of age and the APOE ε4 allele

    Assessment and prescription of aerobic exercise in hydrotherapy [Valoración y prescripción de ejercicio aeróbico en hidroterapia]

    No full text
    The prescription of therapeutic exercise (PTE) in hydrotherapy it is a measure recommended in the medical guides of consent in the recovery of sport. Objective To describe a evaluation specific and reproductible to clarify the approach disparity in the PTE in water, for the control and pursuit of the physiologic parameters in Aerobic Aquatic Exercise (AAE). Material and method I rehearse aleatory controlled on 20 subject male sportsmen of high level, on test validation it diagnoses it specifies in water, correlated with a laboratory. Results Values means were reached bigger than 8 mm/l of maximum lactatemia. They are significant differences (p Discussion The results in the maximum lactatemia suggest that both groups carried out maximum efforts in the test of water, also the differences of FCmax and in the recovery they could be the reflection of a different cardiovascular answer mediated by the means aquatic. Conclusions For the prescription of exercise intensities in the water is necessary to carry out a test I specify in this means, if it is not possible we suggest for population’s type to subtract 10,9% of the reached maximum value the test in laboratory. They are necessary more studies that enlarge the correlation among the tests in dry and the cardiovascular answer in water
    corecore