4 research outputs found

    Two-neutrino double electron capture on 124Xe based on an effective theory and the nuclear shell model

    Get PDF
    We study the two-neutrino double electron capture on 124Xe based on an effective theory (ET) and large-scale shell model calculations, two modern nuclear structure approaches that have been tested against Gamow-Teller and double-beta decay data. In the ET, the low-energy constants are fit to electron capture and transitions around xenon. For the nuclear shell model, we use an interaction in a large configuration space that reproduces the spectroscopy of nuclei in this mass region. For the dominant transition to the 124Te ground state, we find half-lives y for the ET and y for the shell model. The ET uncertainty leads to a half-life almost entirely consistent with present experimental limits and largely within the reach of ongoing experiments. The shell model half-life range overlaps with the ET, but extends less beyond current limits. Our findings thus suggest that the two-neutrino double electron capture on 124Xe has a good chance to be discovered by ongoing or future experiments. In addition, we present results for the two-neutrino double electron capture to excited states of 124Te

    International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module

    No full text
    ‱We report INICC device-associated module data of 50 countries from 2010-2015.‱We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.‱DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.‱Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's. Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific. Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days. Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs. Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically

    Strategies and performance of the CMS silicon tracker alignment during LHC Run 2

    No full text
    The strategies for and the performance of the CMS silicon tracking system alignment during the 2015–2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios
    corecore