902 research outputs found

    Round-Optimal Secure Two-Party Computation from Trapdoor Permutations

    Get PDF
    In this work we continue the study on the round complexity of secure two-party computation with black-box simulation. Katz and Ostrovsky in CRYPTO 2004 showed a 5 (optimal) round construction assuming trapdoor permutations for the general case where both players receive the output. They also proved that their result is round optimal. This lower bound has been recently revisited by Garg et al. in Eurocrypt 2016 where a 4 (optimal) round protocol is showed assuming a simultaneous message exchange channel. Unfortunately there is no instantiation of the protocol of Garg et al. under standard polynomial-time hardness assumptions. In this work we close the above gap by showing a 4 (optimal) round construction for secure two-party computation in the simultaneous message channel model with black-box simulation, assuming trapdoor permutations against polynomial-time adversaries. Our construction for secure two-party computation relies on a special 4-round protocol for oblivious transfer that nicely composes with other protocols in parallel. We define and construct such special oblivious transfer protocol from trapdoor permutations. This building block is clearly interesting on its own. Our construction also makes use of a recent advance on non-malleability: a delayed-input 4-round non-malleable zero knowledge argument

    Device for vitrectomy surgical operations

    Get PDF
    A vitrectomy probe for removing vitreous material from an eyeball, having a longitudinal axis and an outer tube with a closed end and a lateral surface, at least one inlet port located proximate to the closed end and configured to allow the vitreous material to enter into the outer tube; an inner tube arranged in the outer tube to relatively move with respect to the outer tube, the inner tube having an opening with a cutting profile through which the vitreous material can be cut and can enter the inner tube, a drive unit configured for causing the outer tube and the inner tube to move relatively with respect to each other, in such a way that the cutting profile cuts the vitreous material entering the inlet port

    Low-cost smart solutions for daylight and electric lighting integration in historical buildings

    Get PDF
    Research have shown that the correct integration of daylight and electric lighting reduces the energy use in buildings, while improving visual comfort. Smart shading systems, especially those electrically controlled, play an important role to control solar radiation. Similarly, smart and dimmable/tunable lighting can help to adjust the artificial light to the real users' needs. This paper presents preliminary results of an ongoing living lab study investigating how artificial lighting systems can be integrated with shading systems, placing human comfort at the heart of the study and yet saving energy. A manually controlled, commercial and low-cost smart system integrating two motorized shading devices and six dimmable LED luminaires with a different selection of CCT were installed in a private office in a historical building. Indoor and outdoor lighting conditions and energy consumption associated to the lighting system are constantly monitored to assess how the people use shading and lighting upon varying the boundary conditions.. Preliminary results highlight that users prefer to maximise daylight on the work plane as well as they generally use both shading and electric lighting systems in response to boundary conditions that cause serious discomfort

    Estimativa de diversidade genética de Cedro (Meliaceae), uma espécie ameaçada.

    Get PDF
    bitstream/CENARGEN/29612/1/cot171.pd

    Energy performances assessment of extruded and 3d printed polymers integrated into building envelopes for a south Italian case study

    Get PDF
    Plastic materials are increasingly becoming used in the building envelope, despite a lack of investigation on their effects. In this work, an extruded Acrylonitrile-Butadiene-Styrene panel has been tested as a second-skin layer in a ventilated facade system using a full-scale facility. The experimental results show that it is possible to achieve performances very similar to conventional materials. A numerical model has then been developed and used to investigate the performances of plastic and composite polymer panels as second-skin layers. The experimental data has been used to verify the behavior of the numerical model, from a thermal point of view, showing good reliability, with a root mean square error lower than 0.40â—¦C. This model has then been applied in different refurbishment cases upon varying: The polymer and the manufacturing technology (extruded or 3D-printed panels). Eight refurbishment case studies have been carried out on a typical office building located in Napoli (Italy), by means of a dynamic simulation software. The simulation results show that the proposed actions allow the reduction of the thermal and cooling energy demand (up to 6.9% and 3.1%, respectively), as well as the non-renewable primary energy consumption (up to 2.6%), in comparison to the reference case study

    Protocolo para desenvolvimento de marcadores microssatélites.

    Get PDF
    bitstream/CENARGEN/24380/1/ct020.pd

    Electrochemically Generated Luminescence of Luminol and Luciferin in Ionic Liquids

    Get PDF
    Electrochemiluminescence (ECL) is the generation of light triggered by an electrochemical reaction. ECL has been extensively studied in solvent-based electrolytes, but there is a lack of data on using electrode reactions to populate an excited-state light emitter in room temperature ionic liquids (RTILs). This work explores the current response, light intensity (photon counting), and spectral signatures of the cathodic ECL of luminol and firefly's luciferin in imidazolium-based RTILs. We have demonstrated that the cathodic (superoxide-triggered) ECL of both luminol and adenylate-ester of firefly's luciferin is viable in RTILs, explored the effect of water contaminations, and importantly, shown that the ECL signal persists for up to about 700 s after the removal of the external cathodic pulse, which is probably due to the stabilization of superoxide by double-layer cation-rich structures. Long-lived RTIL double-layer structures and their endogenous fields are detected as stable and discrete open-circuit potential plateaus

    Análise genética em populações de Butia eriospatha (Mart. ex Drude) Becc utilizando marcadores moleculares RAPD.

    Get PDF
    bitstream/CENARGEN/29611/1/cot170.pd

    Round Optimal Secure Multiparty Computation from Minimal Assumptions

    Get PDF
    We construct a four round secure multiparty computation (MPC) protocol in the plain model that achieves security against any dishonest majority. The security of our protocol relies only on the existence of four round oblivious transfer. This culminates the long line of research on constructing round-efficient MPC from minimal assumptions (at least w.r.t. black-box simulation)

    Passive Strategies for Building Retrofitting: Performances Analysis and Incentive Policies for the Iranian Scenario

    Get PDF
    A large amount of the Iranian energy demand is related to the building sector, mainly due to its obsolescence. In this paper, a second-skin system has been implemented as a retrofit action for an office building, evaluating the effect of a tensile material as second-skin in terms of primary energy saving, carbon dioxide equivalent emissions, and simple payback period. The analysis was carried out through numerical simulations across a whole year and for four Iranian cities (Tabriz, Teheran, Yazd, and Bandar Abbas) in four different climates (cold, temperate, hot-dry, and hot-wet), and with the building aligned at either north-south or east-west. Moreover, an economic analysis was carried out suggesting different incentive policies to promote building energy refurbishment. The simulation results highlighted a favorable orientation for buildings in Iran, suggesting a guideline for new constructions. Indeed, the best results were achieved for an east-west orientation of the building (up to a primary energy saving of 13.6% and reduction of carbon dioxide equivalent emissions of 45.5 MgCO2,eq, in Yazd), with a decrease of the annual specific total (cooling and thermal) energy demand of 37.9 kWh/m2 /year. The simple payback period values were also lower in the east-west orientation than the north-south one
    • …
    corecore