51 research outputs found

    Automated sulfur-[18F]fluoride exchange radiolabelling of a prostate specific membrane antigen (PSMA) targeted ligand using the GE FASTlabℱ cassette-based platform

    Get PDF
    Sulfur-[18F]fluoride exchange radiochemistry is a rapid and convenient method for incorporating fluorine-18 into biologically active molecules. We report a fully automated radiolabelling procedure for the synthesis of a [18F]SO3F-bearing prostate specific membrane antigen (PSMA) targeted ligand ([18F]5) using the GE FASTLabℱ cassette-based platform in a 25.0 ± 2.6% radiochemical yield (decay corrected). Uptake in vitro and in vivo correlated with PSMA expression, and the radioligand exhibited favourable biodistribution and pharmacokinetic profiles

    Mistral 7B

    Full text link
    We introduce Mistral 7B v0.1, a 7-billion-parameter language model engineered for superior performance and efficiency. Mistral 7B outperforms Llama 2 13B across all evaluated benchmarks, and Llama 1 34B in reasoning, mathematics, and code generation. Our model leverages grouped-query attention (GQA) for faster inference, coupled with sliding window attention (SWA) to effectively handle sequences of arbitrary length with a reduced inference cost. We also provide a model fine-tuned to follow instructions, Mistral 7B -- Instruct, that surpasses the Llama 2 13B -- Chat model both on human and automated benchmarks. Our models are released under the Apache 2.0 license.Comment: Models and code are available at https://mistral.ai/news/announcing-mistral-7b

    Systematic Characterizations of Text Similarity in Full Text Biomedical Publications

    Get PDF
    Computational methods have been used to find duplicate biomedical publications in MEDLINE. Full text articles are becoming increasingly available, yet the similarities among them have not been systematically studied. Here, we quantitatively investigated the full text similarity of biomedical publications in PubMed Central.72,011 full text articles from PubMed Central (PMC) were parsed to generate three different datasets: full texts, sections, and paragraphs. Text similarity comparisons were performed on these datasets using the text similarity algorithm eTBLAST. We measured the frequency of similar text pairs and compared it among different datasets. We found that high abstract similarity can be used to predict high full text similarity with a specificity of 20.1% (95% CI [17.3%, 23.1%]) and sensitivity of 99.999%. Abstract similarity and full text similarity have a moderate correlation (Pearson correlation coefficient: -0.423) when the similarity ratio is above 0.4. Among pairs of articles in PMC, method sections are found to be the most repetitive (frequency of similar pairs, methods: 0.029, introduction: 0.0076, results: 0.0043). In contrast, among a set of manually verified duplicate articles, results are the most repetitive sections (frequency of similar pairs, results: 0.94, methods: 0.89, introduction: 0.82). Repetition of introduction and methods sections is more likely to be committed by the same authors (odds of a highly similar pair having at least one shared author, introduction: 2.31, methods: 1.83, results: 1.03). There is also significantly more similarity in pairs of review articles than in pairs containing one review and one nonreview paper (frequency of similar pairs: 0.0167 and 0.0023, respectively).While quantifying abstract similarity is an effective approach for finding duplicate citations, a comprehensive full text analysis is necessary to uncover all potential duplicate citations in the scientific literature and is helpful when establishing ethical guidelines for scientific publications

    Reporting Magnetic Resonance Imaging in Men on Active Surveillance for Prostate Cancer : The PRECISE Recommendations-A Report of a European School of Oncology Task Force

    Get PDF
    Background: Published data on prostate magnetic resonance imaging (MRI) during follow-up of men on active surveillance are lacking. Current guidelines for prostate MRI reporting concentrate on prostate cancer (PCa) detection and staging. A standardised approach to prostate MRI reporting for active surveillance will facilitate the robust collection of evidence in this newly developing area. Objective: To develop preliminary recommendations for reporting of individual MRI studies in men on active surveillance and for researchers reporting the outcomes of cohorts of men having MRI on active surveillance. Design, setting, and participants: The RAND/UCLA Appropriateness Method was used. Experts in urology, radiology, and radiation oncology developed a set of 394 statements relevant to prostate MRI reporting in men on active surveillance for PCa. Each statement was scored for agreement on a 9-point scale by each panellist prior to a panel meeting. Each statement was discussed and rescored at the meeting. Outcome measurements and statistical analysis: Measures of agreement and consensus were calculated for each statement. The most important statements, derived from both group discussion and scores of agreement and consensus, were used to create the Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) checklist and case report form. Results and limitations: Key recommendations include reporting the index lesion size using absolute values at baseline and at each subsequent MRI. Radiologists should assess the likelihood of true change over time (ie, change in size or change in lesion characteristics on one or more sequences) on a 1-5 scale. A checklist of items for reporting a cohort of men on active surveillance was developed. These items were developed based on expert consensus in many areas in which data are lacking, and they are expected to develop and change as evidence is accrued. Conclusions: The PRECISE recommendations are designed to facilitate the development of a robust evidence database for documenting changes in prostateMRI findings over time ofmen on active surveillance. If used, they will facilitate data collection to distinguish-measurement error and natural variability in MRI appearances from true radiologic progression. Patient summary: Few published reports are available on how to use and interpret magnetic resonance imaging for men on active surveillance for prostate cancer. The PRECISE panel recommends that data should be collected in a standardised manner so that natural variation in the appearance and measurement of cancer over time can be distinguished from changes indicating significant tumour progression. (C) 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.Peer reviewe

    64Cu PET Imaging of the CXCR4 Chemokine Receptor Using a Cross-Bridged Cyclam Bis-Tetraazamacrocyclic Antagonist

    Get PDF
    © 2020 by the Society of Nuclear Medicine and Molecular Imaging. Expression of the chemokine receptor chemokine C-X-C motif receptor 4 (CXCR4) plays an important role in cancer metastasis, in autoimmune diseases, and during stem cell-based repair processes after stroke and myocardial infarction. Previously reported PET imaging agents targeting CXCR4 suffer from either high nonspecific uptake or bind only to the human form of the receptor. The objective of this study was to develop a high-stability 64Cu-labeled small-molecule PET agent for imaging both human and murine CXCR4 chemokine receptors. Methods: Synthesis, radiochemistry, stability and radioligand binding assays were performed for the novel tracer 64Cu-CuCB-bicyclam. In vivo dynamic PET studies were performed on mice bearing U87 (CXCR4 low-expressing) and U87.CXCR4 (human-CXCR4 high-expressing) tumors. Biodistribution and receptor blocking studies were performed on CD1-IGS immunocompetent mice. CXCR4 expression on tumor and liver disaggregates was confirmed using a combination of immunohistochemistry, quantitative polymerase chain reaction, and Western blot. Results:64Cu-CuCB-bicyclam has a high affinity for both the human and the murine variants of the CXCR4 receptor (half-maximal inhibitory concentration, 8 nM [human]/2 nM [murine]) and can be obtained from the parent chelator that has low affinity. In vitro and in vivo studies demonstrate specific uptake in CXCR4-expressing cells that can be blocked by more than 90% using a higher-affinity antagonist, with limited uptake in non-CXCR4-expressing organs and high in vivo stability. The tracer was also able to selectively displace the CXCR4 antagonists AMD3100 and AMD3465 from the liver. Conclusion: The tetraazamacrocyclic small molecule 64Cu-CuCB-bicyclam has been shown to be an imaging agent for the CXCR4 receptor that is likely to be applicable across a range of species. It has high affinity and stability and is suitable for preclinical research in immunocompetent murine models

    A Comparison of Methods for Streamflow Uncertainty Estimation

    Get PDF
    International audienceStreamflow time series are commonly derived from stage-discharge rating curves, but the uncertainty of the rating curve and resulting streamflow series are poorly understood. While different methods to quantify uncertainty in the stage-discharge relationship exist, there is limited understanding of how uncertainty estimates differ between methods due to different assumptions and methodological choices. We compared uncertainty estimates and stage-discharge rating curves from seven methods at three river locations of varying hydraulic complexity. Comparison of the estimated uncertainties revealed a wide range of estimates, particularly for high and low flows. At the simplest site on the IsĂšre River (France), full width 95% uncertainties for the different methods ranged from 3 to 17% for median flows. In contrast, uncertainties were much higher and ranged from 41 to 200% for high flows in an extrapolated section of the rating curve at the Mahurangi River (New Zealand) and 28 to 101% for low flows at the Taf River (United Kingdom), where the hydraulic control is unstable at low flows. Differences between methods result from differences in the sources of uncertainty considered, differences in the handling of the time-varying nature of rating curves, differences in the extent of hydraulic knowledge assumed, and differences in assumptions when extrapolating rating curves above or below the observed gaugings. Ultimately, the selection of an uncertainty method requires a match between user requirements and the assumptions made by the uncertainty method. Given the significant differences in uncertainty estimates between methods, we suggest that a clear statement of uncertainty assumptions be presented alongside streamflow uncertainty estimates

    Systems medicine and integrated care to combat chronic noncommunicable diseases

    Get PDF
    We propose an innovative, integrated, cost-effective health system to combat major non-communicable diseases (NCDs), including cardiovascular, chronic respiratory, metabolic, rheumatologic and neurologic disorders and cancers, which together are the predominant health problem of the 21st century. This proposed holistic strategy involves comprehensive patient-centered integrated care and multi-scale, multi-modal and multi-level systems approaches to tackle NCDs as a common group of diseases. Rather than studying each disease individually, it will take into account their intertwined gene-environment, socio-economic interactions and co-morbidities that lead to individual-specific complex phenotypes. It will implement a road map for predictive, preventive, personalized and participatory (P4) medicine based on a robust and extensive knowledge management infrastructure that contains individual patient information. It will be supported by strategic partnerships involving all stakeholders, including general practitioners associated with patient-centered care. This systems medicine strategy, which will take a holistic approach to disease, is designed to allow the results to be used globally, taking into account the needs and specificities of local economies and health systems

    Simplified quantitation of activated transcription factors

    No full text
    • 

    corecore