23 research outputs found

    A randomized controlled trial on the comparative effectiveness of mindfulness-based cognitive therapy and health qigong-based cognitive therapy among Chinese people with depression and anxiety disorders

    Get PDF
    Background: The goal of this study was to investigate treatment outcome and related intervention processes of mindfulness-based cognitive therapy versus health qigong-based cognitive therapy versus waitlist control among individuals with mood disorders. Methods: A total of 187 individuals with mood disorders were randomized and allocated into mindfulness-based cognitive therapy, health qigong-based cognitive therapy, or waitlist control groups. All participants were assessed at three time points with regard to depressive and anxiety symptoms, physical and mental health status, perceived stress, sleep quality, and self-efficacy. Linear mixed models analysis was used to test the individual growth model by studying the longitudinal data. Results: Mindfulness-based cognitive therapy and health qigong-based cognitive therapy both produced greater improvements on all outcome measures as compared with waitlist control. Relatively, more reductions of mood symptoms were observed in the health qigong-based cognitive therapy group as compared with the mindfulness-based cognitive therapy group. Health qigong-based cognitive therapy is more conducive to physical health status whereas mindfulness-based cognitive therapy has more favorable mental health outcomes. Individual growth curve models indicated that alterations in perceived stress was the common predictor of mood changes in both intervention groups. Conclusions: The predominant emphasis on physical health in health qigong-based cognitive therapy makes it more acceptable and effective than mindfulness-based cognitive therapy as applied in Chinese individuals with mood disorders. The influence of Chinese culture is discussed. Trial registration: HKU Clinical Trials Registry. Identifier: HKUCTR-2558. Registered 21st Nov 2018

    International Recommendations on Reirradiation by Intensity Modulated Radiation Therapy for Locally Recurrent Nasopharyngeal Carcinoma

    Get PDF
    Purpose: Reirradiation for locally recurrent nasopharyngeal carcinoma (NPC) is challenging because prior radiation dose delivered in the first course is often close to the tolerance limit of surrounding normal structures. A delicate balance between achieving local salvage and minimizing treatment toxicities is needed. However, high-level evidence is lacking because available reports are mostly retrospective studies on small series of patients. Pragmatic consensus guidelines, based on an extensive literature search and the pooling of opinions by leading specialists, will provide a useful reference to assist decision-making for these difficult decisions. Methods and Materials: A thorough review of available literature on recurrent NPC was conducted. A set of questions and preliminary draft guideline was circulated to a panel of international specialists with extensive experience in this field for voting on controversial areas and comments. A refined second proposal, based on a summary of the initial voting and different opinions expressed, was recirculated to the whole panel for review and reconsideration. The current guideline was based on majority voting after repeated iteration for final agreement. Results: The initial round of questions showed variations in clinical practice even among the specialists, reflecting the lack of high-quality supporting data and the difficulties in formulating clinical decisions. Through exchange of comments and iterative revisions, recommendations with high-to-moderate agreement were formulated on general treatment strategies and details of reirradiation (including patient selection, targets contouring, dose prescription, and constraints). Conclusion: This paper provides useful reference on radical salvage treatment strategies for recurrent NPC and optimization of reirradiation through review of published evidence and consensus building. However, the final decision by the attending clinician must include full consideration of an individual patient's condition, understanding of the delicate balance between risk and benefits, and acceptance of risk of complications. (C) 2021 Elsevier Inc. All rights reserved

    International Guideline on Dose Prioritization and Acceptance Criteria in Radiation Therapy Planning for Nasopharyngeal Carcinoma

    Get PDF
    Purpose: The treatment of nasopharyngeal carcinoma requires high radiation doses. The balance of the risks of local recurrence owing to inadequate tumor coverage versus the potential damage to the adjacent organs at risk (OARs) is of critical importance. With advancements in technology, high target conformality is possible. Nonetheless, to achieve the best possible dose distribution, optimal setting of dose targets and dose prioritization for tumor volumes and various OARs is fundamental. Radiation doses should always be guided by the As Low As Reasonably Practicable principle. There are marked variations in practice. This study aimed to develop a guideline to serve as a global practical reference. Methods and Materials: A literature search on dose tolerances and normal-tissue complications after treatment for nasopharyngeal carcinoma was conducted. In addition, published guidelines and protocols on dose prioritization and constraints were reviewed. A text document and preliminary set of variants was circulated to a panel of international experts with publications or extensive experience in the field. An anonymized voting process was conducted to rank the proposed variants. A summary of the initial voting and different opinions expressed by members were then recirculated to the whole panel for review and reconsideration. Based on the comments of the panel, a refined second proposal was recirculated to the same panel. The current guideline was based on majority voting after repeated iteration for final agreement. Results: Variation in opinion among international experts was repeatedly iterated to develop a guideline describing appropriate dose prioritization and constraints. The percentage of final agreement on the recommended parameters and alternative views is shown. The rationale for the recommendations and the limitations of current evidence are discussed. Conclusions: Through this comprehensive review of available evidence and interactive exchange of vast experience by international experts, a guideline was developed to provide a practical reference for setting dose prioritization and acceptance criteria for tumor volumes and OARs. The final decision on the treatment prescription should be based on the individual clinical situation and the patient's acceptance of optimal balance of risk. (C) 2019 Elsevier Inc. All rights reserved

    Fine-Scale Mapping of the 4q24 Locus Identifies Two Independent Loci Associated with Breast Cancer Risk

    Get PDF
    Background: A recent association study identified a common variant (rs9790517) at 4q24 to be associated with breast cancer risk. Independent association signals and potential functional variants in this locus have not been explored. Methods: We conducted a fine-mapping analysis in 55,540 breast cancer cases and 51,168 controls from the Breast Cancer Association Consortium. Results: Conditional analyses identified two independent association signals among women of European ancestry, represented by rs9790517 [conditional P = 2.51 × 10−4; OR, 1.04; 95% confidence interval (CI), 1.02–1.07] and rs77928427 (P = 1.86 × 10−4; OR, 1.04; 95% CI, 1.02–1.07). Functional annotation using data from the Encyclopedia of DNA Elements (ENCODE) project revealed two putative functional variants, rs62331150 and rs73838678 in linkage disequilibrium (LD) with rs9790517 (r2 ≥ 0.90) residing in the active promoter or enhancer, respectively, of the nearest gene, TET2. Both variants are located in DNase I hypersensitivity and transcription factor–binding sites. Using data from both The Cancer Genome Atlas (TCGA) and Molecular Taxonomy of Breast Cancer International Consortium (METABRIC), we showed that rs62331150 was associated with level of expression of TET2 in breast normal and tumor tissue. Conclusion: Our study identified two independent association signals at 4q24 in relation to breast cancer risk and suggested that observed association in this locus may be mediated through the regulation of TET2. Impact: Fine-mapping study with large sample size warranted for identification of independent loci for breast cancer risk

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M>70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0<e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    International guideline for the delineation of the clinical target volumes (CTV) for nasopharyngeal carcinoma

    Get PDF
    PURPOSE: Target delineation in nasopharyngeal carcinoma (NPC) often proves challenging because of the notoriously narrow therapeutic margin. High doses are needed to achieve optimal levels of tumour control, and dosimetric inadequacy remains one of the most important independent factors affecting treatment outcome. METHOD: A review of the available literature addressing the natural behaviour of NPC and correlation between clinical and pathological aspects of the disease was conducted. Existing international guidelines as well as published protocols specified by clinical trials on contouring of clinical target volumes (CTV) were compared. This information was then summarized into a preliminary draft guideline which was then circulated to international experts in the field for exchange of opinions and subsequent voting on areas with the greatest controversies. RESULTS: Common areas of uncertainty and variation in practices among experts experienced in radiation therapy for NPC were elucidated. Iterative revisions were made based on extensive discussion and final voting on controversial areas by the expert panel, to formulate the recommendations on contouring of CTV based on optimal geometric expansion and anatomical editing for those structures with substantial risk of microscopic infiltration. CONCLUSION: Through this comprehensive review of available evidence and best practices at major institutions, as well as interactive exchange of vast experience by international experts, this set of consensus guidelines has been developed to provide a practical reference for appropriate contouring to ensure optimal target coverage. However, the final decision on the treatment volumes should be based on full consideration of individual patients' factors and facilities of an individual centre (including the quality of imaging methods and the precision of treatment delivery)
    corecore