6,219 research outputs found
Omega-3 PUFAs and vitamin D co-supplementation as a safe-effective therapeutic approach for core symptoms of autism spectrum disorder: case report and literature review
Introduction: Autism spectrum disorder (ASD) is a group of neurodevelopmental disorders characterized by abnormal development of cognitive, social, and communicative skills. Although ASD aetiology and pathophysiology are still unclear, various nutritional factors have been investigated as potential risk factors for ASD development, including omega-3 polyunsaturated fatty acids (PUFAs) and vitamin D deficiency. In fact, both omega-3 PUFAs and vitamin D are important for brain development and function.
Case report: Herein, we report the case of a 23-year-old young adult male with autism who was referred to our Unit due to a 12-month history of cyclic episodes of restlessness, agitation, irritability, oppositional and self-injurious behaviours. Laboratory tests documented a markedly altered omega-6/omega-3 balance, along with a vitamin D deficiency, as assessed by serum levels of 25-hydroxyvitamin D. Omega-3 and vitamin D co-supplementation was therefore started, with remarkable improvements in ASD symptoms throughout a 24-month follow-up period. A brief review of the literature for interventional studies evaluating the efficacy of omega-3 or vitamin D supplementation for the treatment of ASD-related symptoms is also provided.
Conclusion: To our knowledge, this is the first case reporting remarkable beneficial effects on ASD symptoms deriving from omega-3 and vitamin D combination therapy. This case report suggests omega-3 and vitamin D co-supplementation as a potential safe-effective therapeutic strategy to treat core symptoms of ASD. However, larger studies are needed to evaluate the real efficacy of such therapeutic approach in a broader sample of ASD patients
Recommended from our members
Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons
We describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration
Recommended from our members
Reconstruction and measurement of (100) MeV energy electromagnetic activity from Ď0 arrow γγ decays in the MicroBooNE LArTPC
We present results on the reconstruction of electromagnetic (EM) activity from photons produced in charged current νΟ interactions with final state Ď0s. We employ a fully-automated reconstruction chain capable of identifying EM showers of (100) MeV energy, relying on a combination of traditional reconstruction techniques together with novel machine-learning approaches. These studies demonstrate good energy resolution, and good agreement between data and simulation, relying on the reconstructed invariant Ď0 mass and other photon distributions for validation. The reconstruction techniques developed are applied to a selection of νΟ + Ar â Îź + Ď0 + X candidate events to demonstrate the potential for calorimetric separation of photons from electrons and reconstruction of Ď0 kinematics
Design and construction of the MicroBooNE Cosmic Ray Tagger system
The MicroBooNE detector utilizes a liquid argon time projection chamber
(LArTPC) with an 85 t active mass to study neutrino interactions along the
Booster Neutrino Beam (BNB) at Fermilab. With a deployment location near ground
level, the detector records many cosmic muon tracks in each beam-related
detector trigger that can be misidentified as signals of interest. To reduce
these cosmogenic backgrounds, we have designed and constructed a TPC-external
Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for
High Energy Physics (LHEP), Albert Einstein center for fundamental physics,
University of Bern. The system utilizes plastic scintillation modules to
provide precise time and position information for TPC-traversing particles.
Successful matching of TPC tracks and CRT data will allow us to reduce
cosmogenic background and better characterize the light collection system and
LArTPC data using cosmic muons. In this paper we describe the design and
installation of the MicroBooNE CRT system and provide an overview of a series
of tests done to verify the proper operation of the system and its components
during installation, commissioning, and physics data-taking
Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE
The single-phase liquid argon time projection chamber (LArTPC) provides a
large amount of detailed information in the form of fine-grained drifted
ionization charge from particle traces. To fully utilize this information, the
deposited charge must be accurately extracted from the raw digitized waveforms
via a robust signal processing chain. Enabled by the ultra-low noise levels
associated with cryogenic electronics in the MicroBooNE detector, the precise
extraction of ionization charge from the induction wire planes in a
single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event
display images, and quantitatively demonstrated via waveform-level and
track-level metrics. Improved performance of induction plane calorimetry is
demonstrated through the agreement of extracted ionization charge measurements
across different wire planes for various event topologies. In addition to the
comprehensive waveform-level comparison of data and simulation, a calibration
of the cryogenic electronics response is presented and solutions to various
MicroBooNE-specific TPC issues are discussed. This work presents an important
improvement in LArTPC signal processing, the foundation of reconstruction and
therefore physics analyses in MicroBooNE.Comment: 54 pages, 36 figures; the first part of this work can be found at
arXiv:1802.0870
Ionization Electron Signal Processing in Single Phase LArTPCs I. Algorithm Description and Quantitative Evaluation with MicroBooNE Simulation
We describe the concept and procedure of drifted-charge extraction developed
in the MicroBooNE experiment, a single-phase liquid argon time projection
chamber (LArTPC). This technique converts the raw digitized TPC waveform to the
number of ionization electrons passing through a wire plane at a given time. A
robust recovery of the number of ionization electrons from both induction and
collection anode wire planes will augment the 3D reconstruction, and is
particularly important for tomographic reconstruction algorithms. A number of
building blocks of the overall procedure are described. The performance of the
signal processing is quantitatively evaluated by comparing extracted charge
with the true charge through a detailed TPC detector simulation taking into
account position-dependent induced current inside a single wire region and
across multiple wires. Some areas for further improvement of the performance of
the charge extraction procedure are also discussed.Comment: 60 pages, 36 figures. The second part of this work can be found at
arXiv:1804.0258
A Deep Neural Network for Pixel-Level Electromagnetic Particle Identification in the MicroBooNE Liquid Argon Time Projection Chamber
We have developed a convolutional neural network (CNN) that can make a
pixel-level prediction of objects in image data recorded by a liquid argon time
projection chamber (LArTPC) for the first time. We describe the network design,
training techniques, and software tools developed to train this network. The
goal of this work is to develop a complete deep neural network based data
reconstruction chain for the MicroBooNE detector. We show the first
demonstration of a network's validity on real LArTPC data using MicroBooNE
collection plane images. The demonstration is performed for stopping muon and a
charged current neutral pion data samples
The HEP.TrkX Project: deep neural networks for HL-LHC online and offline tracking
Particle track reconstruction in dense environments such as the detectors of the High Luminosity Large Hadron Collider (HL-LHC) is a challenging pattern recognition problem. Traditional tracking algorithms such as the combinatorial Kalman Filter have been used with great success in LHC experiments for years. However, these state-of-the-art techniques are inherently sequential and scale poorly with the expected increases in detector occupancy in the HL-LHC conditions. The HEP.TrkX project is a pilot project with the aim to identify and develop cross-experiment solutions based on machine learning algorithms for track reconstruction. Machine learning algorithms bring a lot of potential to this problem thanks to their capability to model complex non-linear data dependencies, to learn effective representations of high-dimensional data through training, and to parallelize easily on high-throughput architectures such as GPUs. This contribution will describe our initial explorations into this relatively unexplored idea space. We will discuss the use of recurrent (LSTM) and convolutional neural networks to find and fit tracks in toy detector data
Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV
A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay
channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7
TeV is presented. The data were collected at the LHC, with the CMS detector,
and correspond to an integrated luminosity of 4.6 inverse femtobarns. No
significant excess is observed above the background expectation, and upper
limits are set on the Higgs boson production cross section. The presence of the
standard model Higgs boson with a mass in the 270-440 GeV range is excluded at
95% confidence level.Comment: Submitted to JHE
- âŚ