71 research outputs found
Material screening and selection for XENON100
Results of the extensive radioactivity screening campaign to identify
materials for the construction of XENON100 are reported. This Dark Matter
search experiment is operated underground at Laboratori Nazionali del Gran
Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors
(HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been
applied for a few low mass plastic samples. Detailed tables with the
radioactive contaminations of all screened samples are presented, together with
the implications for XENON100.Comment: 8 pages, 1 figur
The Lamb shift in muonic hydrogen and the proton radius
By means of pulsed laser spectroscopy applied to muonic hydrogen (μ− p) we have measured the 2S F = 1 1/2 − 2PF = 2 3/2 transition frequency to be 49881.88(76) GHz. By comparing this measurement with its theoretical prediction based on bound-state QED we have determined a proton radius value of rp = 0.84184 (67) fm. This new value is an order of magnitude preciser than previous results but disagrees by 5 standard deviations from the CODATA and the electronproton scattering values. An overview of the present effort attempting to solve the observed discrepancy is given. Using the measured isotope shift of the 1S-2S transition in regular hydrogen and deuterium also the rms charge radius of the deuteron rd = 2.12809 (31) fm has been determined. Moreover we present here the motivations for the measurements of the μ 4He + and μ 3He + 2S-2P splittings. The alpha and triton charge radii are extracted from these measurements with relative accuracies of few 10 − 4. Measurements could help to solve the observed discrepancy, lead to the best test of hydrogen-like energy levels and provide crucial tests for few-nucleon ab-initio theories and potentials
The XENON100 Dark Matter Experiment
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.Comment: 23 pages, 27 figures; version accepted by journa
Avaliação das características do líquido ruminal, hemogasometria, atividade pedométrica e diagnóstico de laminite subclínica em vacas leiteiras
Este estudo objetivou avaliar as características do líquido ruminal, hemogasometria, atividade pedométrica e ocorrência laminite subclínica, por meio da presença de enfermidades podais secundárias, em vacas leiteiras de alta produção, provenientes de um rebanho comercial. Foram avaliadas 200 vacas holandesas, oriundas da mesma propriedade, localizada na região de Araçatuba, SP, divididas em quatro grupos, sendo estes estabelecidos a partir da produtividade diária. Inicialmente procedeu-se o exame clínico dos animais, seguido da colheita de amostras do líquido ruminal, por meio de sondagem esofágica, sendo este avaliado quanto ao pH, cor, odor, consistência, sedimentação, flutuação e prova de redução pelo azul de metileno. Também foram colhidas amostras de sangue venoso para hemogasometria, além da coleta dos dados da pedometria (número de passos) e produção de leite diária das vacas. Os dados obtidos foram tabulados e submetidos à análise de correlação. Nenhum animal avaliado apresentou alterações no pH ruminal, bem como não foram encontrados distúrbios do desequilíbrio ácido básico, pois os valores de pH sanguíneo, PCO2, TCO2, HCO3- e EB estavam dentro da normalidade, durante a análise hemogasométrica. A pedometria foi efetiva como método de triagem para as vacas acometidas de afecções podais, pois se observou a redução no número de passos devido à dor, correlacionada a menor produção leiteira. Contudo, a identificação destas afecções, somente foi possível mediante exame clínico específico dos dígitos. A ocorrência das afecções podais em 49,5% do rebanho deveu-se aos fatores de riscos presentes na propriedade, como o concreto abrasivo e instalações inadequadas, associados também a possível ocorrência de acidose ruminal subaguda, não diagnosticada pela metodologia utilizada. A correlação entre os valores do pH ruminal, pedometria e hemogasometria se mostrou eficiente para o diagnóstico precoce das afecções podais e também no estabelecimento da etiologia destas enfermidades. A laminite subclínica acometeu primariamente as vacas do rebanho, considerando a etiologia multifatorial desta afecção, ocorrência e distribuição das enfermidades podais diagnosticadas
Planar LAAPDs: temperature dependence, performance, and application in low-energy X-ray spectroscopy
- …