112 research outputs found

    Coffee consumption increases the antioxidant capacity of plasma and has no effect on the lipid profile or vascular function in healthy adults in a randomized controlled trial

    Get PDF
    ABSTRACT: Coffee, a source of antioxidants, has controversial effects on cardiovascular health. Objective: We evaluated the bioavailability of chlorogenic acids (CGAs) in 2 coffees and the effects of their consumption on the plasma antioxidant capacity (AC), the serum lipid profile, and the vascular function in healthy adults. Methods: Thirty-eight men and 37 women with a mean 6 SD age of 38.5 6 9 y and body mass index of 24.1 6 2.6 kg/m2 were randomly assigned to 3 groups: a control group that did not consume coffee or a placebo and 2 groups that consumed 400 mL coffee/d for 8 wk containing a medium (MCCGA; 420 mg) or high (HCCGA; 780 mg) CGA content. Both were low in diterpenes (0.83 mg/d) and caffeine (193 mg/d). Plasma caffeic and ferulic acid concentrations were measured by GC, and the plasma AC was evaluated with use of the ferric-reducing antioxidant power method. The serum lipid profile, nitric oxide (NO) plasma metabolites, vascular endothelial function (flow-mediated dilation; FMD), and blood pressure (BP) were evaluated.Results: After coffee consumption (1 h and 8 wk), caffeic and ferulic acid concentrations increased in the coffee-drinking groups, although the values of the 2 groups were significantly different (P < 0.001); caffeic and ferulic acid concentrations were undetectable in the control group. At 1 h after consumption, the plasma AC in the control group was significantly lower than the baseline value (22%) and significantly increased in the MCCGA (6%) and HCCGA (5%) groups (P < 0.05). After 8 wk, no significant differences in the lipid, FMD, BP, or NO plasma metabolite values were observed between the groups. Conclusions: Both coffees, which contained CGAs and were low in diterpenes and caffeine, provided bioavailable CGAs and had a positive acute effect on the plasma AC in healthy adults and no effect on blood lipids or vascular function. The group that did not drink coffee showed no improvement in serum lipid profile, FMD, BP, or NO plasma metabolites. This trial was registered at registroclinico.sld.cu as RPCEC00000168

    Session-based concurrency, declaratively

    Get PDF
    Session-based concurrency is a type-based approach to the analysis of message-passing programs. These programs may be specified in an operational or declarative style: the former defines how interactions are properly structured; the latter defines governing conditions for correct interaction

    Biofabrication of functional protein nanoparticles through simple His-tag engineering

    Get PDF
    Altres ajuts: Acord transformatiu CRUE-CSICWe have developed a simple, robust, and fully transversal approach for thea-la-cartefabrication of functional multimeric nanoparticles with potential biomedical applications, validated here by a set of diverse and unrelated polypeptides. The proposed concept is based on the controlled coordination between Znions and His residues in His-tagged proteins. This approach results in a spontaneous and reproducible protein assembly as nanoscale oligomers that keep the original functionalities of the protein building blocks. The assembly of these materials is not linked to particular polypeptide features, and it is based on an environmentally friendly and sustainable approach. The resulting nanoparticles, with dimensions ranging between 10 and 15 nm, are regular in size, are architecturally stable, are fully functional, and serve as intermediates in a more complex assembly process, resulting in the formation of microscale protein materials. Since most of the recombinant proteins produced by biochemical and biotechnological industries and intended for biomedical research are His-tagged, the green biofabrication procedure proposed here can be straightforwardly applied to a huge spectrum of protein species for their conversion into their respective nanostructured formats

    Comunicar ciencia en México. Prácticas y escenarios

    Get PDF
    Este volumen permite profundizar en las prácticas y los escenarios de la comunicación de la ciencia en México. En sus capítulos se abordan desde temas generales en materia de investigación y divulgación de la ciencia en el país, hasta aspectos específicos de estas áreas mediante un rico conjunto de estudios de caso que tratan cuestiones como la construcción simbólica del futuro en la ficción, la narrativa de la ciencia, el proceso de producción del proyecto de divulgación denominado La batalla de las ciencias, o las implicaciones de los recursos de autoridad al elegir una licenciatura en física, química o biología

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Association between T2-related co-morbidities and effectiveness of biologics in severe asthma

    Get PDF
    Acknowledgments The authors thank Mr. Joash Tan (BSc, Hons), of the Observational and Pragmatic Research Institute (OPRI), and Ms Andrea Lim (BSc, Hons) of the Observational Pragmatic Research Institute (OPRI) for their editorial and formatting assistance that supported the development of this publication. Funding statement: This study was conducted by the Observational and Pragmatic Research Institute (OPRI) Pte Ltd and was partially funded by Optimum Patient Care Global and AstraZeneca Ltd. AstraZeneca UK LimitedPeer reviewe

    First results from the AugerPrime Radio Detector

    Get PDF

    Update of the Offline Framework for AugerPrime

    Get PDF
    corecore