236 research outputs found

    Imaging Findings in Patients with Immune Checkpoint Inhibitor-Induced Arthritis

    Full text link
    Immune checkpoint inhibitor (ICI)-induced arthritis is an increasingly recognized adverse event in patients with oncologic disease during immunotherapy. Four patterns are well described, including rheumatoid arthritis (RA)-like, polymyalgia rheumatica (PMR)-like, psoriatic arthritis (PsA)-like, and oligo-monoarthritis, among others. Despite better clinical recognition of these syndromes, information about the main imaging findings is limited. Methods: We conducted a retrospective observational study including all adult patients referred to the Rheumatology Department of a single-center due to ICI-induced arthritis who underwent imaging studies [ultrasound (US), magnetic resonance imaging (MRI), and (18)F-FDG PET/CT)] between January 2017 and January 2022. Results: Nineteen patients with ICI-induced arthritis with at least one diagnostic imaging assessment were identified (15 US, 4 MRI, 2 (18)F-FDG PET/CT). Most patients were male (84.2%), with a median age at inclusion of 73 years. The main underlying diagnoses for ICI treatment were melanoma in five cases. The distribution of ICI-induced arthritis was as follows: PMR-like (5, 26.2%), RA-like (4, 21.1%), PsA-like (4, 21.1%), and others (6, 31.6%). All RA-like patients had US findings indistinguishable from conventional RA patients. In addition, 3/5 (60%) of PMR-like patients had significant involvement of the hands and wrists. Abnormal findings on MRI or PET-CT were reported by clinical symptoms. No erosions or myofascitis were seen. Conclusions: ICI-induced arthritis patients present inflammatory patterns on imaging studies similar to conventional inflammatory arthropathies, and therefore these syndromes should be followed carefully and treated according to these findings

    Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the rr-process calculations

    Full text link
    The rare-earth peak in the rr-process abundance pattern depends sensitively on both the astrophysical conditions and subtle changes in nuclear structure in the region. This work takes an important step elucidating the nuclear structure and reducing the uncertainties in rr-process calculations via precise atomic mass measurements at the JYFLTRAP double Penning trap. 158^{158}Nd, 160^{160}Pm, 162^{162}Sm, and 164166^{164-166}Gd have been measured for the first time and the precisions for 156^{156}Nd, 158^{158}Pm, 162,163^{162,163}Eu, 163^{163}Gd, and 164^{164}Tb have been improved considerably. Nuclear structure has been probed via two-neutron separation energies S2nS_{2n} and neutron pairing energy metrics DnD_n. The data do not support the existence of a subshell closure at N=100N=100. Neutron pairing has been found to be weaker than predicted by theoretical mass models. The impact on the calculated rr-process abundances has been studied. Substantial changes resulting in a smoother abundance distribution and a better agreement with the solar rr-process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review Letter

    Measuring and modelling the energy cost of reconfiguration in sensor networks [forthcoming]

    Get PDF
    As Wireless Sensor Networks (WSN) must operate for long periods on a limited power budget, estimating the energy cost of software operations is critical. Contemporary reconfiguration approaches for WSN allow for software evolution at various granularities; from reflashing of a complete software image, through replacement of complete applications, to the reconfiguration of individual software components. This paper contributes a generic model for measuring and modelling the energy cost of reconfiguration in WSN. We validate that this model is accurate in the face of different hardware platforms, software stacks and software encapsulation approaches. We have embedded this model in the LooCI middleware, resulting in the first energy aware reconfigurable component model for sensor networks. We evaluate our approach using two real-world WSN applications and demonstrate that our model predicts the energy cost of reconfiguration with 93% accuracy. Using this model we demonstrate that selecting the most appropriate software modularisation approach is key to minimising energy consumption

    The Advanced LIGO Photon Calibrators

    Get PDF
    The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as Photon Calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO Photon Calibrators that are currently providing fiducial displacements on the order of 101810^{-18} m/Hz\sqrt{\textrm{Hz}} with accuracy and precision of better than 1 %.Comment: 14 pages, 19 figure

    Revealing the mid-infrared emission structure of IRAS 16594-4656 and IRAS 07027-7934

    Full text link
    TIMMI2 diffraction-limited mid-infrared images of a multipolar proto-planetary nebula IRAS 16594-4656 and a young [WC] elliptical planetary nebula IRAS 07027-7934 are presented. Their dust shells are for the first time resolved (only marginally in the case of IRAS 07027-7934) by applying the Lucy-Richardson deconvolution algorithm to the data, taken under exceptionally good seeing conditions (<0.5"). IRAS 16594-4656 exhibits a two-peaked morphology at 8.6, 11.5 and 11.7 microns which is mainly attributed to emission from PAHs. Our observations suggest that the central star is surrounded by a toroidal structure observed edge-on with a radius of 0.4" (~640 AU at an assumed distance of 1.6 kpc) with its polar axis at P.A.~80 degrees, coincident with the orientation defined by only one of the bipolar outflows identified in the HST optical images. We suggest that the material expelled from the central source is currently being collimated in this direction and that the multiple outflow formation has not been coeval. IRAS 07027-7934 shows a bright, marginally extended emission (FWHM=0.3") in the mid-infrared with a slightly elongated shape along the N-S direction, consistent with the morphology detected by HST in the near-infrared. The mid-infrared emission is interpreted as the result of the combined contribution of small, highly ionized PAHs and relatively hot dust continuum. We propose that IRAS 07027-7934 may have recently experienced a thermal pulse (likely at the end of the AGB) which has produced a radical change in the chemistry of its central star.Comment: 35 pages, 8 figures (figures 1, 2, 4 and 6 are in low resolution) accepted for publication in Ap

    Phase II study of irinotecan in combination with temozolomide (TEMIRI) in children with recurrent or refractory medulloblastoma: a joint ITCC and SIOPE brain tumor study

    Get PDF
    BackgroundThis multicenter phase II study investigated temozolomide + irinotecan (TEMIRI) treatment in children with relapsed or refractory medulloblastoma.MethodsPatients received temozolomide 100–125 mg/m2/day (days 1–5) and irinotecan 10 mg/m2/day (days 1–5 and 8–12) every 3 weeks. The primary endpoint was tumor response within the first 4 cycles confirmed ≥4 weeks and assessed by an external response review committee (ERRC). In a 2-stage Optimum Simon design, ≥6 responses in the first 15 evaluable patients were required within the first 4 cycles for continued enrollment; a total of 19 responses from the first 46 evaluable patients was considered successful.ResultsSixty-six patients were treated. Seven responses were recorded during stage 1 and 15 in the first 46 ERRC evaluated patients (2 complete responses and 13 partial responses). The objective response rate during the first 4 cycles was 32.6% (95% confidence interval [CI], 19.5%–48.0%). Median duration of response was 27.0 weeks (7.7–44.1 wk). In 63 patients evaluated by local investigators, the objective response rate was 33.3% (95% CI, 22.0%–46.3%), and 68.3% (95% CI, 55.3%–79.4%) experienced clinical benefit. Median survival was 16.7 months (95% CI, 13.3–19.8). The most common grade 3 treatment-related nonhematologic adverse event was diarrhea (7.6%). Grade 3/4 treatment-related hematologic adverse events included neutropenia (16.7%), thrombocytopenia (12.1%), anemia (9.1%), and lymphopenia (9%).ConclusionsThe planned study primary endpoint was not met. However, its tolerability makes TEMIRI a suitable candidate chemotherapy backbone for molecularly targeted agents in future trials in this setting

    High-precision mass measurements for the isobaric multiplet mass equation at A=52

    Get PDF
    Masses of Co-52, (52)Com, Fe-52, Fe-52(m), and Mn-52 have been measured with the JYFLTRAP double Penning trap mass spectrometer. The isobaric multiplet mass equation for the T = 2 quintet at A = 52 has been studied employing the new mass values. No significant breakdown (beyond the 3 sigma level) of the quadratic form of the IMME was observed (chi(2)/n = 2.4). The cubic coefficient was 6.0(32) keV (chi(2)/n = 1.1). The excitation energies for the isomer and the T = 2 isobaric analog state in Co-52 have been determined to be 374(13) keV and 2922(13) keV, respectively. The measured mass values for Co-52 and (52)Com are 29(10) keV and 16(15) keV higher, respectively, than obtained in a recent storage-ring experiment, and significantly lower than predicted by extrapolations. Consequently, this has an impact on the proton separation energies for Co-52 and Ni-53 relevant for the astrophysical rapid proton capture process. The Q value for the proton decay from the 19/2(-) isomer in Co-53 has been determined with an unprecedented precision, Q(p) = 1558.8(17) keV.Peer reviewe
    corecore