241 research outputs found
Imaging Findings in Patients with Immune Checkpoint Inhibitor-Induced Arthritis
Immune checkpoint inhibitor (ICI)-induced arthritis is an increasingly recognized adverse event in patients with oncologic disease during immunotherapy. Four patterns are well described, including rheumatoid arthritis (RA)-like, polymyalgia rheumatica (PMR)-like, psoriatic arthritis (PsA)-like, and oligo-monoarthritis, among others. Despite better clinical recognition of these syndromes, information about the main imaging findings is limited. Methods: We conducted a retrospective observational study including all adult patients referred to the Rheumatology Department of a single-center due to ICI-induced arthritis who underwent imaging studies [ultrasound (US), magnetic resonance imaging (MRI), and (18)F-FDG PET/CT)] between January 2017 and January 2022. Results: Nineteen patients with ICI-induced arthritis with at least one diagnostic imaging assessment were identified (15 US, 4 MRI, 2 (18)F-FDG PET/CT). Most patients were male (84.2%), with a median age at inclusion of 73 years. The main underlying diagnoses for ICI treatment were melanoma in five cases. The distribution of ICI-induced arthritis was as follows: PMR-like (5, 26.2%), RA-like (4, 21.1%), PsA-like (4, 21.1%), and others (6, 31.6%). All RA-like patients had US findings indistinguishable from conventional RA patients. In addition, 3/5 (60%) of PMR-like patients had significant involvement of the hands and wrists. Abnormal findings on MRI or PET-CT were reported by clinical symptoms. No erosions or myofascitis were seen. Conclusions: ICI-induced arthritis patients present inflammatory patterns on imaging studies similar to conventional inflammatory arthropathies, and therefore these syndromes should be followed carefully and treated according to these findings
Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the -process calculations
The rare-earth peak in the -process abundance pattern depends sensitively
on both the astrophysical conditions and subtle changes in nuclear structure in
the region. This work takes an important step elucidating the nuclear structure
and reducing the uncertainties in -process calculations via precise atomic
mass measurements at the JYFLTRAP double Penning trap. Nd, Pm,
Sm, and Gd have been measured for the first time and the
precisions for Nd, Pm, Eu, Gd, and
Tb have been improved considerably. Nuclear structure has been probed
via two-neutron separation energies and neutron pairing energy metrics
. The data do not support the existence of a subshell closure at .
Neutron pairing has been found to be weaker than predicted by theoretical mass
models. The impact on the calculated -process abundances has been studied.
Substantial changes resulting in a smoother abundance distribution and a better
agreement with the solar -process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review
Letter
Measuring and modelling the energy cost of reconfiguration in sensor networks [forthcoming]
As Wireless Sensor Networks (WSN) must operate for long periods on a limited power budget, estimating the energy cost of software operations is critical. Contemporary reconfiguration approaches for WSN allow for software evolution at various granularities; from reflashing of a complete software image, through replacement of complete applications, to the reconfiguration of individual software components. This paper contributes a generic model for measuring and modelling the energy cost of reconfiguration in WSN. We validate that this model is accurate in the face of different hardware platforms, software stacks and software encapsulation approaches. We have embedded this model in the LooCI middleware, resulting in the first energy aware reconfigurable component model for sensor networks. We evaluate our approach using two real-world WSN applications and demonstrate that our model predicts the energy cost of reconfiguration with 93% accuracy. Using this model we demonstrate that selecting the most appropriate software modularisation approach is key to minimising energy consumption
The Advanced LIGO Photon Calibrators
The two interferometers of the Laser Interferometry Gravitaional-wave
Observatory (LIGO) recently detected gravitational waves from the mergers of
binary black hole systems. Accurate calibration of the output of these
detectors was crucial for the observation of these events, and the extraction
of parameters of the sources. The principal tools used to calibrate the
responses of the second-generation (Advanced) LIGO detectors to gravitational
waves are systems based on radiation pressure and referred to as Photon
Calibrators. These systems, which were completely redesigned for Advanced LIGO,
include several significant upgrades that enable them to meet the calibration
requirements of second-generation gravitational wave detectors in the new era
of gravitational-wave astronomy. We report on the design, implementation, and
operation of these Advanced LIGO Photon Calibrators that are currently
providing fiducial displacements on the order of
m/ with accuracy and precision of better than 1 %.Comment: 14 pages, 19 figure
Revealing the mid-infrared emission structure of IRAS 16594-4656 and IRAS 07027-7934
TIMMI2 diffraction-limited mid-infrared images of a multipolar
proto-planetary nebula IRAS 16594-4656 and a young [WC] elliptical planetary
nebula IRAS 07027-7934 are presented. Their dust shells are for the first time
resolved (only marginally in the case of IRAS 07027-7934) by applying the
Lucy-Richardson deconvolution algorithm to the data, taken under exceptionally
good seeing conditions (<0.5"). IRAS 16594-4656 exhibits a two-peaked
morphology at 8.6, 11.5 and 11.7 microns which is mainly attributed to emission
from PAHs. Our observations suggest that the central star is surrounded by a
toroidal structure observed edge-on with a radius of 0.4" (~640 AU at an
assumed distance of 1.6 kpc) with its polar axis at P.A.~80 degrees, coincident
with the orientation defined by only one of the bipolar outflows identified in
the HST optical images. We suggest that the material expelled from the central
source is currently being collimated in this direction and that the multiple
outflow formation has not been coeval. IRAS 07027-7934 shows a bright,
marginally extended emission (FWHM=0.3") in the mid-infrared with a slightly
elongated shape along the N-S direction, consistent with the morphology
detected by HST in the near-infrared. The mid-infrared emission is interpreted
as the result of the combined contribution of small, highly ionized PAHs and
relatively hot dust continuum. We propose that IRAS 07027-7934 may have
recently experienced a thermal pulse (likely at the end of the AGB) which has
produced a radical change in the chemistry of its central star.Comment: 35 pages, 8 figures (figures 1, 2, 4 and 6 are in low resolution)
accepted for publication in Ap
Phase II study of irinotecan in combination with temozolomide (TEMIRI) in children with recurrent or refractory medulloblastoma: a joint ITCC and SIOPE brain tumor study
BackgroundThis multicenter phase II study investigated temozolomide + irinotecan (TEMIRI) treatment in children with relapsed or refractory medulloblastoma.MethodsPatients received temozolomide 100–125 mg/m2/day (days 1–5) and irinotecan 10 mg/m2/day (days 1–5 and 8–12) every 3 weeks. The primary endpoint was tumor response within the first 4 cycles confirmed ≥4 weeks and assessed by an external response review committee (ERRC). In a 2-stage Optimum Simon design, ≥6 responses in the first 15 evaluable patients were required within the first 4 cycles for continued enrollment; a total of 19 responses from the first 46 evaluable patients was considered successful.ResultsSixty-six patients were treated. Seven responses were recorded during stage 1 and 15 in the first 46 ERRC evaluated patients (2 complete responses and 13 partial responses). The objective response rate during the first 4 cycles was 32.6% (95% confidence interval [CI], 19.5%–48.0%). Median duration of response was 27.0 weeks (7.7–44.1 wk). In 63 patients evaluated by local investigators, the objective response rate was 33.3% (95% CI, 22.0%–46.3%), and 68.3% (95% CI, 55.3%–79.4%) experienced clinical benefit. Median survival was 16.7 months (95% CI, 13.3–19.8). The most common grade 3 treatment-related nonhematologic adverse event was diarrhea (7.6%). Grade 3/4 treatment-related hematologic adverse events included neutropenia (16.7%), thrombocytopenia (12.1%), anemia (9.1%), and lymphopenia (9%).ConclusionsThe planned study primary endpoint was not met. However, its tolerability makes TEMIRI a suitable candidate chemotherapy backbone for molecularly targeted agents in future trials in this setting
High-precision mass measurements for the isobaric multiplet mass equation at A=52
Masses of Co-52, (52)Com, Fe-52, Fe-52(m), and Mn-52 have been measured with the JYFLTRAP double Penning trap mass spectrometer. The isobaric multiplet mass equation for the T = 2 quintet at A = 52 has been studied employing the new mass values. No significant breakdown (beyond the 3 sigma level) of the quadratic form of the IMME was observed (chi(2)/n = 2.4). The cubic coefficient was 6.0(32) keV (chi(2)/n = 1.1). The excitation energies for the isomer and the T = 2 isobaric analog state in Co-52 have been determined to be 374(13) keV and 2922(13) keV, respectively. The measured mass values for Co-52 and (52)Com are 29(10) keV and 16(15) keV higher, respectively, than obtained in a recent storage-ring experiment, and significantly lower than predicted by extrapolations. Consequently, this has an impact on the proton separation energies for Co-52 and Ni-53 relevant for the astrophysical rapid proton capture process. The Q value for the proton decay from the 19/2(-) isomer in Co-53 has been determined with an unprecedented precision, Q(p) = 1558.8(17) keV.Peer reviewe
- …