10 research outputs found
The impact of high‐density spatial sampling versus antenna orientation on 3D GPR fracture imaging
Three-dimensional Ground Penetrating Radar (3D GPR) surveys are necessary to reconstruct complex fracture geometries in the subsurface. Two of the most important factors controlling image quality are antenna orientation relative to fractures and density of acquisition grids. This study, conducted in the Madonna della Mazza quarry (Italy), compares two acquisition methods with the goal of optimizing the imaging of fractures and related 3D fracture networks. We acquired two very dense, orthogonal 3D GPR surveys with a 250 MHz antenna and 5 cm trace spacing on the same day, covering the same area of 20 x 20 m. By decimation of the original raw datasets, reduced survey densities of 10 cm and 20 cm spacing are simulated. The results show differences in the imaging quality of the two methods to depths of 75 cm, while for a depth of 130 cm and deeper, image quality is similar. At the same trace density/m2, a single, unidirectional survey with a densely sampled grid is the preferred method rather than two surveys with orthogonal antenna orientations but larger profile spacing. The extra effort of conducting surveys with an acquisition grid of an eighth of wavelength of the antenna centre frequency guarantees that we can properly sample the high-frequency content of the GPR signal spectrum and results in optimum image quality regardless of fracture orientation. The simple survey design principle found in this study is universally applicable to any field condition, target geometry, and antenna frequency. Such high-density 3D GPR survey design enables the high-resolution characterization of 3D fracture networks on subsurface timeslices in near photographic quality
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Perhaps more than any other “-omics” endeavor, the accuracy and level of detail obtained from mapping the major connection pathways in the living human brain with diffusion MRI depends on the capabilities of the imaging technology used. The current tools are remarkable; allowing the formation of an “image” of the water diffusion probability distribution in regions of complex crossing fibers at each of half a million voxels in the brain. Nonetheless our ability to map the connection pathways is limited by the image sensitivity and resolution, and also the contrast and resolution in encoding of the diffusion probability distribution. The goal of our Human Connectome Project (HCP) is to address these limiting factors by re-engineering the scanner from the ground up to optimize the high b-value, high angular resolution diffusion imaging needed for sensitive and accurate mapping of the brain’s structural connections. Our efforts were directed based on the relative contributions of each scanner component. The gradient subsection was a major focus since gradient amplitude is central to determining the diffusion contrast, the amount of T(2) signal loss, and the blurring of the water PDF over the course of the diffusion time. By implementing a novel 4-port drive geometry and optimizing size and linearity for the brain, we demonstrate a whole-body sized scanner with G(max) = 300mT/m on each axis capable of the sustained duty cycle needed for diffusion imaging. The system is capable of slewing the gradient at a rate of 200 T/m/s as needed for the EPI image encoding. In order to enhance the efficiency of the diffusion sequence we implemented a FOV shifting approach to Simultaneous MultiSlice (SMS) EPI capable of unaliasing 3 slices excited simultaneously with a modest g-factor penalty allowing us to diffusion encode whole brain volumes with low TR and TE. Finally we combine the multi-slice approach with a compressive sampling reconstruction to sufficiently undersample q-space to achieve a DSI scan in less than 5 minutes. To augment this accelerated imaging approach we developed a 64-channel, tight-fitting brain array coil and show its performance benefit compared to a commercial 32-channel coils at all locations in the brain for these accelerated acquisitions. The technical challenges of developing the over-all system are discussed as well as results from SNR comparisons, ODF metrics and fiber tracking comparisons. The ultra-high gradients yielded substantial and immediate gains in the sensitivity through reduction of TE and improved signal detection and increased efficiency of the DSI or HARDI acquisition, accuracy and resolution of diffusion tractography, as defined by identification of known structure and fiber crossing
What we learn about bipolar disorder from large-scale neuroimaging: Findings and future directions from the ENIGMA Bipolar Disorder Working Group
MRI-derived brain measures offer a link between genes, the environment and behavior and have been widely studied in bipolar disorder (BD). However, many neuroimaging studies of BD have been underpowered, leading to varied results and uncertainty regarding effects. The Enhancing Neuro Imaging Genetics through Meta-Analysis (ENIGMA) Bipolar Disorder Working Group was formed in 2012 to empower discoveries, generate consensus findings and inform future hypothesis-driven studies of BD. Through this effort, over 150 researchers from 20 countries and 55 institutions pool data and resources to produce the largest neuroimaging studies of BD ever conducted. The ENIGMA Bipolar Disorder Working Group applies standardized processing and analysis techniques to empower large-scale meta- and mega-analyses of multimodal brain MRI and improve the replicability of studies relating brain variation to clinical and genetic data. Initial BD Working Group studies reveal widespread patterns of lower cortical thickness, subcortical volume and disrupted white matter integrity associated with BD. Findings also include mapping brain alterations of common medications like lithium, symptom patterns and clinical risk profiles and have provided further insights into the pathophysiological mechanisms of BD. Here we discuss key findings from the BD working group, its ongoing projects and future directions for large-scale, collaborative studies of mental illness
Safety of hospital discharge before return of bowel function after elective colorectal surgery
Background: Ileus is common after colorectal surgery and is associated with an increased risk of postoperative complications. Identifying features of normal bowel recovery and the appropriateness for hospital discharge is challenging. This study explored the safety of hospital discharge before the return of bowel function. Methods: A prospective, multicentre cohort study was undertaken across an international collaborative network. Adult patients undergoing elective colorectal resection between January and April 2018 were included. The main outcome of interest was readmission to hospital within 30 days of surgery. The impact of discharge timing according to the return of bowel function was explored using multivariable regression analysis. Other outcomes were postoperative complications within 30 days of surgery, measured using the Clavien\u2013Dindo classification system. Results: A total of 3288 patients were included in the analysis, of whom 301 (9\ub72 per cent) were discharged before the return of bowel function. The median duration of hospital stay for patients discharged before and after return of bowel function was 5 (i.q.r. 4\u20137) and 7 (6\u20138) days respectively (P < 0\ub7001). There were no significant differences in rates of readmission between these groups (6\ub76 versus 8\ub70 per cent; P = 0\ub7499), and this remained the case after multivariable adjustment for baseline differences (odds ratio 0\ub790, 95 per cent c.i. 0\ub755 to 1\ub746; P = 0\ub7659). Rates of postoperative complications were also similar in those discharged before versus after return of bowel function (minor: 34\ub77 versus 39\ub75 per cent; major 3\ub73 versus 3\ub74 per cent; P = 0\ub7110). Conclusion: Discharge before return of bowel function after elective colorectal surgery appears to be safe in appropriately selected patients