12 research outputs found

    A challenge to organization of the heart team

    Get PDF
    publishersversionpublishe

    Coronary computed tomography angiography-adapted Leaman score as a tool to noninvasively quantify total coronary atherosclerotic burden

    Get PDF
    To describe a coronary computed tomography angiography (CCTA)-adapted Leaman score (CT-LeSc) as a tool to quantify total coronary atherosclerotic burden with information regarding localization, type of plaque and degree of stenosis and to identify clinical predictors of a high coronary atherosclerotic burden as assessed by the CT-LeSc. Single center prospective registry including a total of 772 consecutive patients undergoing CCTA (Dual-source CT) from April 2011 to March 2012. For the purpose of this study, 581 stable patients referred for suspected coronary artery disease (CAD) without previous myocardial infarction or revascularization procedures were included. Pre-test CAD probability was determined using both the Diamond-Forrester extended CAD consortium method (DF-CAD consortium model) and the Morise score. Cardiovascular risk was assessed with the HeartScore. The cut-off for the 3rd tercile (CT-LeSc ≥8.3) was used to define a population with a high coronary atherosclerotic burden. The median CT-LeSc in this population (n = 581, 8,136 coronary segments evaluated; mean age 57.6 ± 11.1; 55.8 % males; 14.6 % with diabetes) was 2.2 (IQR 0-6.8). In patients with CAD (n = 341), the median CT-LeSc was 5.8 (IQR 3.2-9.6). Among patients with nonobstructive CAD, most were classified in the lowest terciles (T1, 43.0 %; T2, 36.1 %), but 20.9 % were in the highest tercile (T3). The majority of the patients with obstructive CAD were classified in T3 (78.2 %), but 21.8 % had a CT-LeSc in lower terciles (T1 or T2). The independent predictors of a high CT-LeSc were: Male sex (OR 1.73; 95 % CI 1.04-2.90) diabetes (OR 2.91; 95 % CI 1.61-5.23), hypertension (OR 2.54; 95 % CI 1.40-4.63), Morise score ≥16 (OR 1.97; 95 % CI 1.06-3.67) and HeartScore ≥5 (OR 2.42; 95 % CI 1.41-4.14). We described a cardiac CT adapted Leaman score as a tool to quantify total (obstructive and nonobstructive) coronary atherosclerotic burden, reflecting the comprehensive information about localization, degree of stenosis and type of plaque provided by CCTA. Male sex, hypertension, diabetes, a HeartScore ≥5 % and a Morise score ≥16 were associated with a high coronary atherosclerotic burden, as assessed by the CT-LeSc. About one fifth of the patients with nonobstructive CAD had a CT-LeSc in the highest tercile, and this could potentially lead to a reclass

    Quinze anos de ecografia intravascular coronária emintervenc ̧ão coronária percutânea em Portugal

    Get PDF
    INTRODUCTION: Coronary intravascular ultrasound (IVUS) is increasingly important in catheterization laboratories due to its positive prognostic impact. This study aims to characterize the use of IVUS in percutaneous coronary intervention (PCI) in Portugal. METHODS: A retrospective observational study was performed based on the Portuguese Registry on Interventional Cardiology of the Portuguese Society of Cardiology. The clinical and angiographic profiles of patients who underwent PCI between 2002 and 2016, the percentage of IVUS use, and the coronary arteries assessed were characterized. RESULTS: A total of 118 706 PCIs were included, in which IVUS was used in 2266 (1.9%). Over time, use of IVUS changed from none in 2002 to generally increasing use from 2003 (0.1%) to 2016 (2.4%). The age of patients in whom coronary IVUS was used was similar to that of patients in whom IVUS was not used, but in the former group there were fewer male patients, and a higher prevalence of cardiovascular risk factors (hypertension, hypercholesterolemia and diabetes), previous myocardial infarction, previous PCI, multivessel coronary disease, C-type or bifurcated coronary lesions, and in-stent restenosis. IVUS was used in 54.8% of elective PCIs and in 19.15% of PCIs of the left main coronary artery. CONCLUSION: Coronary IVUS has been increasingly used in Portugal since 2003. It is used preferentially in elective PCIs, and in patients with higher cardiovascular risk, with more complex coronary lesions and lesions of the left main coronary artery.info:eu-repo/semantics/publishedVersio

    Modifying effect of dual antiplatelet therapy on incidence of stent thrombosis according to implanted drug-eluting stent type

    Get PDF
    Aim To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Methods and results Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). Conclusion A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957

    Posição sobre Suportes Vasculares Restaurativos Transitórios Coronários em Portugal

    Get PDF
    BACKGROUND: Bioresorbable vascular scaffolds (BVS) were recently approved for percutaneous coronary intervention in Europe. The aim of this position statement is to review the information and studies on available BVS, to stimulate discussion on their use and to propose guidelines for this treatment option in Portugal. METHODS AND RESULTS: A working group was set up to reach a consensus based on current evidence, discussion of clinical case models and individual experience. The evidence suggests that currently available BVS can produce physiological and clinical improvements in selected patients. There are encouraging data on their durability and long-term safety. Initial indications were grouped into three categories: (a) consensual and appropriate - young patients, diabetic patients, left anterior descending artery, long lesions, diffuse disease, and hybrid strategy; (b) less consensual but possible - small collateral branches, stabilized acute coronary syndromes; and (c) inappropriate - left main disease, tortuosity, severe calcification. CONCLUSION: BVS are a viable treatment option based on the encouraging evidence of their applicability and physiological and clinical results. They should be used in appropriate indications and will require technical adaptations. Outcome monitoring and evaluation is essential to avoid inappropriate use. It is recommended that medical societies produce clinical guidelines based on high-quality registries as soon as possible

    Impacto Clínico em Curto e Longo Prazo da Válvula Aórtica Percutânea (VAP) em Portugal de Acordo com Diferentes Acessos – Dados do Registo Nacional de Cardiologia de Intervenção de VAP

    No full text
    Introduction: The Portuguese National Registry of Transcatheter Aortic Valve Implantation records prospectively the characteristics and outcomes of transcatheter aortic valve implantation (TAVI) procedures in Portugal. Objectives: To assess the 30-day and one-year outcomes of TAVI procedures in Portugal. Methods: We compared TAVI results according to the principal access used (transfemoral (TF) vs. non-transfemoral (non-TF)). Cumulative survival curves according to access route, other procedural and clinical variables were obtained. The Valve Academic Research Consortium-2 (VARC-2) composite endpoint of early (30-days) safety was assessed. VARC-2 predictors of 30-days and 1-year all-cause mortality were identified. Results: Between January 2007 and December 2018, 2346 consecutive patients underwent TAVI (2242 native, 104 valve-in-valve; mean age 81±7 years, 53.2% female, EuroSCORE-II - EuroS-II, 4.3%). Device success was 90.1% and numerically lower for non-TF (87.0%). Thirty-day all-cause mortality was 4.8%, with the TF route rendering a lower mortality rate (4.3% vs. 10.1%, p=0.001) and higher safety endpoint (86.4% vs. 72.6%, p5% (p<0.001) and who underwent non-TF TAVI (p<0.001). Conclusion: Data from our national real-world registry showed that TAVI was safe and effective. The use of a non-transfemoral approach demonstrated safety in the short term. Long-term prognosis was, however, adversely associated with this route, with comorbidities and the baseline clinical status.info:eu-repo/semantics/publishedVersio

    Transcatheter aortic valve implantation (TAVI) in cardiogenic shock: TAVI-shock registry results

    No full text
    Objectives: Aim of this study is to evaluate safety, feasibility, and mid-term outcome of transcatheter aortic valve implantation (TAVI) in cardiogenic shock (CS). Background: Balloon aortic valvuloplasty in patients with severe aortic valve stenosis (SAS) complicated by CS is indicated but associated with a grim prognosis. TAVI might be a more reasonable treatment option in this setting but data are scant. Methods: From March 2008 to February 2019, 51 patients with severe aortic valvulopathy (native SAS or degenerated aortic bioprosthesis) and CS treated by TAVI in 11 European centers were included in this multicenter registry. Demographic, clinical, and procedural data were collected, as well as clinical and echocardiographic follow-up. Results: The mean age of our study population was 75.8 \ub1 13, 49% were women, and mean Society of Thoracic Surgeons (STS) score was 19 \ub1 15%. Device success was achieved in 94.1%, with a 5% incidence of moderate/severe paravalvular leak. The 30-day events were mortality 11.8%, stroke 2.0%, vascular complications 5.9%, and acute kidney injury 34%. Valve Academic Research Consortium-2 early safety endpoint was reached in 35.3% of cases. At 1-year of follow-up, the mortality rate was 25.7% and the readmission for congestive heart failure was 8.6%. Conclusions: TAVI seems to be a therapeutic option for patients with CS and SAS or degenerated aortic bioprosthesis in terms of both safety and efficacy at early and long-term follow-up

    Next-generation balloon-expandable Myval transcatheter heart valve in low-risk aortic stenosis patients

    No full text
    Objectives: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. Background: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. Methods: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. Results: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6&nbsp;cm2) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p &lt; 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. Conclusions: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted

    Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves

    No full text
    .Aims: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. Methods and results: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 \ub1 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) 64 20 mm] compared with those with large-failed bioprostheses (ID &gt; 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. Conclusions: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV

    Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement: Comprehensive Mid-Term Evaluation of Valve-in-Valve and Valve-in-Ring Implantation from the VIVID Registry

    Get PDF
    Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining mid-term outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient 6510 mmHg and significant residual mitral regurgitation (MR) as 65 moderate. Results: A total of 1,079 patients (857 ViV, 222 ViR; mean age 73.5 years \ub1 12.5; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days [IQR 76 - 996 days]; median echocardiographic follow-up for patients that survived 1 year 772.5 days [IQR 510 - 1211.75 days]. Four-year Kaplan-Meier survival rate was 62.5% in ViV vs. 49.5% for ViR (p&lt;0.001). Mean gradient across the mitral valve post-procedure was 5.7 \ub1 2.8 mmHg ( 655mmHg, 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (p=0.09). Significant residual MR was more common in ViR patients (16.6% vs. 3.1%; p&lt;0.001) and was associated with lower survival at 4 years (35.1% vs. 61.6%; p=0.02). The rates of MVARC-defined device success were low for both procedures (39.4% total; 32.0% ViR vs. 41.3% ViV; p=0.01), mostly related to having post-procedural mean gradient 655mmHg. Correlates for residual MS were smaller true internal diameter, younger age and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (SHR 4.67; 95% CI 1.74 - 12.56; p=0.002) and significant residual MR (SHR 7.88; 95% CI 2.88 - 21.53; p&lt;0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve post-procedural hemodynamics in mitral ViV and ViR should be further explored
    corecore