116 research outputs found

    Differential cross sections and spin density matrix elements for the reaction gamma p -> p omega

    Full text link
    High-statistics differential cross sections and spin density matrix elements for the reaction gamma p -> p omega have been measured using the CLAS at Jefferson Lab for center-of-mass (CM) energies from threshold up to 2.84 GeV. Results are reported in 112 10-MeV wide CM energy bins, each subdivided into cos(theta_CM) bins of width 0.1. These are the most precise and extensive omega photoproduction measurements to date. A number of prominent structures are clearly present in the data. Many of these have not previously been observed due to limited statistics in earlier measurements

    Loss of paraplegin drives spasticity rather than ataxia in a cohort of 241 patients with SPG7

    Get PDF
    Objective : We took advantage of a large multinational recruitment to delineate genotype-phenotype correlations in a large, trans-European multicenter cohort of patients with spastic paraplegia gene 7 (SPG7). Methods : We analyzed clinical and genetic data from 241 patients with SPG7, integrating neurologic follow-up data. One case was examined neuropathologically. Results : Patients with SPG7 had a mean age of 35.5 +/- 14.3 years (n = 233) at onset and presented with spasticity (n = 89), ataxia (n = 74), or both (n = 45). At the first visit, patients with a longer disease duration (> 20 years, n = 62) showed more cerebellar dysarthria (p < 0.05), deep sensory loss (p < 0.01), muscle wasting (p < 0.01), ophthalmoplegia (p < 0.05), and sphincter dysfunction (p < 0.05) than those with a shorter duration (< 10 years, n = 93). Progression, measured by Scale for the Assessment and Rating of Ataxia evaluations, showed a mean annual increase of 1.0 +/- 1.4 points in a subgroup of 30 patients. Patients homozygous for loss of function (LOF) variants (n = 65) presented significantly more often with pyramidal signs (p < 0.05), diminished visual acuity due to optic atrophy (p < 0.0001), and deep sensory loss (p < 0.0001) than those with at least 1 missense variant (n = 176). Patients with at least 1 Ala510Val variant (58%) were older (age 37.6 +/- 13.7 vs 32.8 +/- 14.6 years, p < 0.05) and showed ataxia at onset (p < 0.05). Neuropathologic examination revealed reduction of the pyramidal tract in the medulla oblongata and moderate loss of Purkinje cells and substantia nigra neurons. Conclusions : This is the largest SPG7 cohort study to date and shows a spasticity-predominant phenotype of LOF variants and more frequent cerebellar ataxia and later onset in patients carrying at least 1 Ala510Val variant

    Bone mineral content and areal density, but not bone area, predict an incident fracture risk: a comparative study in a UK prospective cohort

    Get PDF
    We studied a prospective UK cohort of women aged 20 to 80 years, assessed by dual-energy X-ray absorptiometry (DXA) at baseline. Bone mineral content (BMC) and areal bone mineral density (aBMD), but not bone area (BA), at femoral neck, lumbar spine and the whole body sites were similarly predictive of incident fractures. BACKGROUND: Low aBMD, measured by DXA, is a well-established risk factor for future fracture, but little is known about the performance characteristics of other DXA measures such as BA and BMC in fracture prediction. We therefore investigated the predictive value of BA, BMC and aBMD for incident fracture in a prospective cohort of UK women. METHODS: In this study, 674 women aged 20-80 years, recruited from four GP practices in Southampton, underwent DXA assessment (proximal femur, lumbar spine, total body) between 1991 and 1993. All women were contacted in 1998-1999 with a validated postal questionnaire to collect information on incident fractures and potential confounding factors including medication use. Four hundred forty-three women responded, and all fractures were confirmed by the assessment of images and radiology reports by a research nurse. Cox proportional hazard models were used to explore the risk of incident fracture, and the results are expressed as hazard ratio (HR) per 1 SD decrease in the predictor and 95% CI. Associations were adjusted for age, BMI, alcohol consumption, smoking, HRT, medications and history of fracture. RESULTS: Fifty-five women (12%) reported a fracture. In fully adjusted models, femoral neck BMC and aBMD were similarly predictive of incident fracture. Femoral neck BMC: HR/SD = 1.64 (95%CI: 1.19, 2.26; p = 0.002); femoral neck aBMD: HR/SD = 1.76 (95%CI: 1.19, 2.60; p = 0.005). In contrast, femoral neck BA was not associated with incident fracture, HR/SD = 1.15 (95%CI: 0.88, 1.50; p = 0.32). Similar results were found with bone indices at the lumbar spine and the whole body. CONCLUSIONS: In conclusion, BMC and aBMD appear to predict incident fracture with similar HR/SD, even after adjustment for body size. In contrast, BA only weakly predicted the future fracture. These findings support the use of DXA aBMD in fracture risk assessment, but also suggest that factors which specifically influence BMC will have a relevance to the risk of the incident fracture

    Molecular architecture of the Nup84–Nup145C–Sec13 edge element in the nuclear pore complex lattice

    Get PDF
    Nuclear pore complexes (NPCs) facilitate all nucleocytoplasmic transport. These massive protein assemblies are modular, with a stable structural scaffold supporting more dynamically attached components. The scaffold is made from multiple copies of the heptameric Y complex and the heteromeric Nic96 complex. We previously showed that members of these core subcomplexes specifically share an ACE1 fold with Sec31 of the COPII vesicle coat, and we proposed a lattice model for the NPC based on this commonality. Here we present the crystal structure of the heterotrimeric 134-kDa complex of Nup84–Nup145C–Sec13 of the Y complex. The heterotypic ACE1 interaction of Nup84 and Nup145C is analogous to the homotypic ACE1 interaction of Sec31 that forms COPII lattice edge elements and is inconsistent with the alternative 'fence-like' NPC model. We construct a molecular model of the Y complex and compare the architectural principles of COPII and NPC lattices.National Institutes of Health (U.S.) (Grant GM77537)Pew Charitable Trusts (Scholar Award

    The combined positive impact of Lean methodology and Ventana Symphony autostainer on histology lab workflow

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Histologic samples all funnel through the H&E microtomy staining area. Here manual processes intersect with semi-automated processes creating a bottleneck. We compare alternate work processes in anatomic pathology primarily in the H&E staining work cell.</p> <p>Methods</p> <p>We established a baseline measure of H&E process impact on personnel, information management and sample flow from historical workload and production data and direct observation. We compared this to performance after implementing initial Lean process modifications, including workstation reorganization, equipment relocation and workflow levelling, and the Ventana Symphony stainer to assess the impact on productivity in the H&E staining work cell.</p> <p>Results</p> <p>Average time from gross station to assembled case decreased by 2.9 hours (12%). Total process turnaround time (TAT) exclusive of processor schedule changes decreased 48 minutes/case (4%). Mean quarterly productivity increased 8.5% with the new methods. Process redesign reduced the number of manual steps from 219 to 182, a 17% reduction. Specimen travel distance was reduced from 773 ft/case to 395 ft/case (49%) overall, and from 92 to 53 ft/case in the H&E cell (42% improvement).</p> <p>Conclusions</p> <p>Implementation of Lean methods in the H&E work cell of histology can result in improved productivity, improved through-put and case availability parameters including TAT.</p

    Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Get PDF
    The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 μ\mum thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to 310153 \cdot 10^{15} neq/cm2^2. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations

    PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH<sub>2</sub>O (ZEEP), associated to a manual bilateral thoracic compression.</p> <p>Aim</p> <p>To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients.</p> <p>Methods</p> <p>15 patients submitted to a coronary artery bypass graft surgery (CABG) were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH<sub>2</sub>O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH<sub>2</sub>O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished.</p> <p>Results</p> <p>The inspiratory peak and plateau pressures increased during the procedure (p < 0.001) compared with other pressures during the assessment periods; however, they were within lung safe limits. The expiratory flow before the procedure were 33 ± 7.87 L/min, increasing significantly during the procedure to 60 ± 6.54 L/min (p < 0.001), diminishing to 35 ± 8.17 L/min at 10 minutes and to 36 ± 8.48 L/min at 30 minutes. Hemodynamic and oxygenation variables were not altered.</p> <p>Conclusion</p> <p>The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.</p

    Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Several cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported.</p> <p>Case presentation</p> <p>In November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty. In March 2008, while rising from a chair, she felt a sudden pain and instability in her left knee. She reported a fracture of the polyethylene post of the tibial insert. No malposition or malalignment of either the femoral or tibial components were identified. The polyethylene tibial insert was studied under light microscopy and scanning electron microscopy. The fracture was also noted to have occurred without any notable polyethylene wear.</p> <p>Conclusion</p> <p>Scanning electron microscopy revealed two different damage patterns that could be explained with a two-stage rupture of our patient's polyethylene post. This could have been caused by a non-optimal ligamentous balancing during first implant surgery. Her knee probably developed a varus instability that weakened the post, and then a posterior anterior stress finally broke the polyethylene.</p
    corecore