612 research outputs found
Is there any Evidence for Regional Atmospheric 14C Offsets in the Southern Hemisphere?
Center for Accelerator Mass Spectrometry (CAMS) Tasmanian huon pine (Lagarostrobos franklinii) decadal measurements for the interval AD 745–855 suggest a mean interhemispheric radiocarbon offset (20 ± 5 yr), which is considerably lower than the previously reported mean interhemispheric offset for the last 2 millennia (44 ± 17 yr). However, comparable University of Waikato (Wk) New Zealand kauri (Agathis australis) measurements show significantly higher values (56 ± 6 yr), suggesting the possibility of a temporary geographic (intrahemispheric) offset between Tasmania, Australia, and Northland, New Zealand, during at least 1 common time interval. Here, we report 9 new Wk Tasmanian huon pine measurements from the decades showing the largest huon/kauri difference. We show statistically indistinguishable Wk huon and Wk kauri 14C ages, thus dispelling the suggestion of a 14C geographic offset between Tasmania and Northland
Impact on the biomechanics of overground gait of using an ‘Echelon’ hydraulic ankle–foot device in unilateral trans-tibial and trans-femoral amputees
YesIf a prosthetic foot creates resistance to forwards shank rotation as it deforms during loading, it will exert a braking effect on centre of mass progression. The present study determines whether the centre of mass braking effect exerted by an amputee's habitual rigid ‘ankle’ foot was reduced when they switched to using an ‘Echelon’ hydraulic ankle–foot device.
Nineteen lower limb amputees (eight trans-femoral, eleven trans-tibial) walked overground using their habitual dynamic-response foot with rigid ‘ankle’ or ‘Echelon’ hydraulic ankle–foot device. Analysis determined changes in how the centre of mass was transferred onto and above the prosthetic-foot, freely chosen walking speed, and spatio-temporal parameters of gait.
When using the hydraulic device both groups had a smoother/more rapid progression of the centre of pressure beneath the prosthetic hindfoot (p ≤ 0.001), and a smaller reduction in centre of mass velocity during prosthetic-stance (p < 0.001). As a result freely chosen walking speed was higher in both groups when using the device (p ≤ 0.005). In both groups stance and swing times and cadence were unaffected by foot condition whereas step length tended (p < 0.07) to increase bilaterally when using the hydraulic device. Effect size differences between foot types were comparable across groups.
Use of a hydraulic ankle–foot device reduced the foot's braking effect for both amputee groups. Findings suggest that attenuation of the braking effect from the foot in early stance may be more important to prosthetic-foot function than its ability to return energy in late stance
Gait Asymmetry Post-Stroke: Determining Valid and Reliable Methods Using a Single Accelerometer Located on the Trunk
Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry
Recommended from our members
Which prosthetic foot to prescribe? Biomechanical differences found during a single session comparison of different foot types hold true one year later
YesIntroduction: Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to ‘try out’ a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to patient related factors which can change from day-to-day and can thus make device comparisons unreliable. To determine whether a device’s mechanical function consistently has a more meaningful impact on gait than patient-related factors, the present study undertook quantitative gait analyses of a trans-tibial amputee walking using two different foot-ankle devices on two occasions over a year apart. If the observed differences present between devices, established using quantitative gait analysis, were in the same direction and of similar magnitude on each of the two occasions, this would indicate that device-related factors were more important than patient-related factors.
Methods: One adult male with a unilateral trans-tibial amputation completed repeated walking trials using two different prosthetic foot devices on two separate occasions, 14 months apart. Walking speed and sagittal plane joint kinematics and kinetics for both limbs were assessed on each occasion. Clinically meaningful differences in these biomechanical outcome variables were defined as those with an effect size difference (d) between prosthetic conditions of at least 0.4 (i.e. ‘medium’ effect size).
Results: Eight variables namely, walking speed, prosthetic ‘ankle’ peak plantar- and dorsi- flexion and peak positive power, and residual knee loading response flexion, peak stance-phase extension and flexion moments and peak negative power, displayed clinically meaningful differences (d > 0.4) between foot devices during the first session. All eight of these showed similar effect size differences during the second session despite the participant being heavier and older.
Conclusions: Findings suggest that a prosthetic device’s mechanical function consistently has a more meaningful impact on gait than patient-related factors. These findings support the current clinical practice of making decisions regarding prosthetic prescription for an individual, based on a single session evaluation of their gait using two different devices. However, to confirm this conclusion, a case series using the same approach as the present study could be undertaken
Walking speed related joint kinetic alterations in trans-tibial amputees: impact of hydraulic 'ankle' damping
YesPassive prosthetic devices are set up to provide optimal function at customary walking speed and thus may function less effectively at other speeds. This partly explains why joint kinetic adaptations become more apparent in lower-limb amputees when walking at speeds other than customary. The present study determined whether a trans-tibial prosthesis incorporating a dynamic-response foot that was attached to the shank via an articulating hydraulic device (hyA-F) lessened speed-related adaptations in joint kinetics compared to when the foot was attached via a rigid, non-articulating attachment (rigF). Eight active unilateral trans-tibial amputees completed walking trials at their customary walking speed, and at speeds they deemed to be slow-comfortable and fast-comfortable whilst using each type of foot attachment. Moments and powers at the distal end of the prosthetic shank and at the intact joints of both limbs were compared between attachment conditions. There was no change in the amount of intact-limb ankle work across speed or attachment conditions. As speed level increased there was an increase on both limbs in the amount of hip and knee joint work done, and increases on the prosthetic side were greater when using the hyA-F. However, because all walking speed levels were higher when using the hyA-F, the intact-limb ankle and combined joints work per meter travelled were significantly lower; particularly so at the customary speed level. This was the case despite the hyA-F dissipating more energy during stance. In addition, the amount of eccentric work done per meter travelled became increased at the residual knee when using the hyA-F, with increases again greatest at customary speed. Findings indicate that a trans-tibial prosthesis incorporating a dynamic-response foot reduced speed-related changes in compensatory intact-limb joint kinetics when the foot was attached via an articulating hydraulic device compared to rigid attachment. As differences between attachment conditions were greatest at customary speed, findings indicate a hydraulic ankle-foot device is most effectual at the speed it is set-up for
The effects of laterality on obstacle crossing performance in unilateral trans-tibial amputees
yesBackground
Unilateral trans-tibial amputees have bilaterally reduced toe clearance, and an increased risk of foot contact, while crossing obstacles compared to the able-bodied. While the able-bodied tend to lead with a ‘preferred’ limb it is equivocal whether amputees prefer to lead with the intact or prosthetic limb. This study determined the effects of laterality, compared to side of amputation, on amputees' obstacle crossing performance. To help understand why laterality could affect performance we also assessed knee proprioception for both limbs.
Methods
Foot placement and toe clearance parameters were recorded while nine amputees crossed obstacles of varying heights leading with both their intact and prosthetic limbs. Joint-position sense was also assessed. Participants self-reported which limb was their preferred (dominant) limb.
Findings
There were no significant differences in foot placements or toe clearance variability across lead-limb conditions. There were no significant differences in toe clearance between intact and prosthetic lead-limbs (p = 0.28) but toe clearance was significantly higher when amputees led with their preferred compared to non-preferred limb (p = 0.025). There was no difference in joint-position sense between the intact and residual knees (p = 0.34) but joint-position sense tended to be more accurate for the preferred, compared to non-preferred limb (p = 0.08).
Interpretation
Findings suggest that, despite the mechanical constraints imposed by use of a prosthesis, laterality may be as important in lower-limb amputees as it is in the able bodied. This suggests that amputees should be encouraged to cross obstacles leading with their preferred limb.Engineering and Physical Sciences Research Counci
Evaluation of daily walking activity and gait profiles: a novel application of a time series analysis framework
Wearable technology allows an in-depth analysis of gait behaviour in free-living environments. This investigation aimed to use Alzheimer's disease as an example to apply the time series analysis technique of Statistical Parametric Mapping (SPM) to create daily gait profiles and test if they differed from cognitively intact controls. A framework of macro (habitual walking behaviours) and micro characteristics (spatiotemporal gait variables) characteristics were calculated on an hourly basis. SPM showed that select micro gait characteristics differed from controls at specific hours of the day. Therefore, the application of SPM may provide a more in-depth reflection of activity and gait time-dependent fluctuations than commonly used whole day values. Considering macro and micro gait hour-by- hour may have applications towards disease management, personalized care, monitoring medication and targeted interventions for people with a range of neurodegenerative diseases
Stair-specific algorithms for identification of touch-down and foot-off when descending or ascending a non-instrumented staircase.
yesThe present study introduces four event detection algorithms for defining touch-down and foot-off during stair descent and stair ascent using segmental kinematics. For stair descent, vertical velocity minima of the whole body center-of-mass was used to define touch-down, and foot-off was defined as the instant of trail limb peak knee flexion. For stair ascent, vertical velocity local minima of the lead-limb toe was used to define touch-down, and foot-off was defined as the local maxima in vertical displacement between the toe and pelvis. The performance of these algorithms was determined as the agreement in timings of kinematically derived events to those defined kinetically (ground reaction forces). Data were recorded while 17 young and 15 older adults completed stair descent and ascent trials over a four-step instrumented staircase. Trials were repeated for three stair riser height conditions (85 mm, 170 mm, and 255 mm). Kinematically derived touch-down and foot-off events showed good agreement (small 95% limits of agreement) with kinetically derived events for both young and older adults, across all riser heights, and for both ascent and descent. In addition, agreement metrics were better than those returned using existing kinematically derived event detection algorithms developed for overground gait. These results indicate that touch-down and foot-off during stair ascent and descent of non-instrumented staircases can be determined with acceptable precision using segmental kinematic data
Long range LiDAR characterisation for obstacle detection for use by the visually impaired and blind
Obstacle detection and avoidance is a huge area of interest for autonomous vehicles and, as such, has become an important research topic. Detecting and identifying obstacles enables navigation through an ever changing environment. This work looks at the technology used in self-driving vehicles and examines whether the same technology could be used to aid in navigation for visually impaired and blind (VIB) people. For autonomous vehicles, obstacle detection relies on different sensor modalities to provide information on the vehicles surroundings. A combination of the same sensors placed on a white cane could be used to perform free-space assessment over the whole height of the user and provide additional environmental information not available from the cane alone. This provides its own challenges and advantages. The speeds are much slower when dealing with pedestrians and scanning can be achieved by the movement of the cane. However, the weight and size must be significantly reduced. The full system will be integrated into a smart cane and will consist of four main sensors as well as range sensors. The aim of this work is to report on the characterisation of a long range LiDAR (up to 10m) that will be integrated into a smart white cane developed as part of the INSPEX H2020 project
Electrodynamics with Lorentz-violating operators of arbitrary dimension
The behavior of photons in the presence of Lorentz and CPT violation is
studied. Allowing for operators of arbitrary mass dimension, we classify all
gauge-invariant Lorentz- and CPT-violating terms in the quadratic Lagrange
density associated with the effective photon propagator. The covariant
dispersion relation is obtained, and conditions for birefringence are
discussed. We provide a complete characterization of the coefficients for
Lorentz violation for all mass dimensions via a decomposition using
spin-weighted spherical harmonics. The resulting nine independent sets of
spherical coefficients control birefringence, dispersion, and anisotropy. We
discuss the restriction of the general theory to various special models,
including among others the minimal Standard-Model Extension, the isotropic
limit, the case of vacuum propagation, the nonbirefringent limit, and the
vacuum-orthogonal model. The transformation of the spherical coefficients for
Lorentz violation between the laboratory frame and the standard Sun-centered
frame is provided. We apply the results to various astrophysical observations
and laboratory experiments. Astrophysical searches of relevance include studies
of birefringence and of dispersion. We use polarimetric and dispersive data
from gamma-ray bursts to set constraints on coefficients for Lorentz violation
involving operators of dimensions four through nine, and we describe the mixing
of polarizations induced by Lorentz and CPT violation in the cosmic-microwave
background. Laboratory searches of interest include cavity experiments. We
present the theory for searches with cavities, derive the experiment-dependent
factors for coefficients in the vacuum-orthogonal model, and predict the
corresponding frequency shift for a circular-cylindrical cavity.Comment: 58 pages two-column REVTeX, accepted in Physical Review
- …