201 research outputs found

    Application of physical parameter identification to finite-element models

    Get PDF
    The time domain parameter identification method described previously is applied to TRW's Large Space Structure Truss Experiment. Only control sensors and actuators are employed in the test procedure. The fit of the linear structural model to the test data is improved by more than an order of magnitude using a physically reasonable parameter set. The electro-magnetic control actuators are found to contribute significant damping due to a combination of eddy current and back electro-motive force (EMF) effects. Uncertainties in both estimated physical parameters and modal behavior variables are given

    Application of physical parameter identification to finite element models

    Get PDF
    A time domain technique for matching response predictions of a structural dynamic model to test measurements is developed. Significance is attached to prior estimates of physical model parameters and to experimental data. The Bayesian estimation procedure allows confidence levels in predicted physical and modal parameters to be obtained. Structural optimization procedures are employed to minimize an error functional with physical model parameters describing the finite element model as design variables. The number of complete FEM analyses are reduced using approximation concepts, including the recently developed convoluted Taylor series approach. The error function is represented in closed form by converting free decay test data to a time series model using Prony' method. The technique is demonstrated on simulated response of a simple truss structure

    Two-Stage Passive Vibration Isolator

    Get PDF
    The design and testing of a structural system were implemented to hold the optics of the planned Space Interferometry Mission (SIM) at positions and orientations characterized by vibrational translation and rotation errors of no more than a few nanometers or a few milliarcseconds, respectively. Much of the effort was devoted to a test bed for verifying the predicted behavior of a vibration- isolation structural subsystem working together with an active control system for positioning and orienting the SIM optics. There was considerable emphasis on the vibration-isolation subsystem, which was passive and comprised two stages. The main sources of vibration were six reaction wheels in an assembly denoted the "backpack." The first vibration-isolation stage consisted of hexapod isolator mounts - one for each reaction wheel - characterized by a natural vibration frequency of 10 Hz. The second stage was a set of three beams, disposed between the backpack and the structure that held the SIM optics, that were flexured such that they transmitted only bending loads, with a natural vibrational frequency and damping of about 5 Hz and 4 percent, respectively. Preliminary test results were presented and characterized as demonstrating the effectiveness of the two-stage vibration-isolation design

    Boceprevir for untreated chronic HCV genotype 1 infection.

    No full text
    International audienceBACKGROUND: Peginterferon-ribavirin therapy is the current standard of care for chronic infection with hepatitis C virus (HCV). The rate of sustained virologic response has been below 50% in cases of HCV genotype 1 infection. Boceprevir, a potent oral HCV-protease inhibitor, has been evaluated as an additional treatment in phase 1 and phase 2 studies. METHODS: We conducted a double-blind study in which previously untreated adults with HCV genotype 1 infection were randomly assigned to one of three groups. In all three groups, peginterferon alfa-2b and ribavirin were administered for 4 weeks (the lead-in period). Subsequently, group 1 (the control group) received placebo plus peginterferon-ribavirin for 44 weeks; group 2 received boceprevir plus peginterferon-ribavirin for 24 weeks, and those with a detectable HCV RNA level between weeks 8 and 24 received placebo plus peginterferon-ribavirin for an additional 20 weeks; and group 3 received boceprevir plus peginterferon-ribavirin for 44 weeks. Nonblack patients and black patients were enrolled and analyzed separately. RESULTS: A total of 938 nonblack and 159 black patients were treated. In the nonblack cohort, a sustained virologic response was achieved in 125 of the 311 patients (40%) in group 1, in 211 of the 316 patients (67%) in group 2 (P<0.001), and in 213 of the 311 patients (68%) in group 3 (P<0.001). In the black cohort, a sustained virologic response was achieved in 12 of the 52 patients (23%) in group 1, in 22 of the 52 patients (42%) in group 2 (P=0.04), and in 29 of the 55 patients (53%) in group 3 (P=0.004). In group 2, a total of 44% of patients received peginterferon-ribavirin for 28 weeks. Anemia led to dose reductions in 13% of controls and 21% of boceprevir recipients, with discontinuations in 1% and 2%, respectively. CONCLUSIONS: The addition of boceprevir to standard therapy with peginterferon-ribavirin, as compared with standard therapy alone, significantly increased the rates of sustained virologic response in previously untreated adults with chronic HCV genotype 1 infection. The rates were similar with 24 weeks and 44 weeks of boceprevir

    UDP-glucuronosyltransferase UGT1A7 genetic polymorphisms in hepatocellular carcinoma: a differential impact according to seropositivity of HBV or HCV markers?

    Get PDF
    <p>Abstract</p> <p>Background:</p> <p>We conducted a case-control study to evaluate the role of UDP-glucuronosyltransferase 1A7 (UGT1A7) polymorphisms in the onset of hepatocellular carcinoma (HCC).</p> <p>Methods:</p> <p>The study included 165 patients with HCC, 134 with cirrhosis and 142 controls without liver disease, matched for age and hospital. All were men younger than 75 years. HCC and cirrhosis patients were stratified according to time since cirrhosis diagnosis.</p> <p>Results:</p> <p>We found a positive association between the UGT1A7*3/*3 genotype and HCC when the comparison was restricted to patients whose disease was of viral origin [OR = 3.4 (0.3–45)] but a negative association when it included only alcoholic patients [OR = 0.1 (0.02–0.6), p = 0.01].</p> <p>Conclusion:</p> <p>Our study shows that UGT1A7 may play a role in hepatocellular carcinogenesis and that this role may differ according to the primary cause of the cirrhosis.</p

    Methyl donor deficiency impairs fatty acid oxidation through PGC-1α hypomethylation and decreased ER-α, ERR-α, and HNF-4α in the rat liver

    Get PDF
    BACKGROUND &amp; AIMS: Folate and cobalamin are methyl donors needed for the synthesis of methionine, which is the precursor of S-adenosylmethionine, the substrate of methylation in epigenetic, and epigenomic pathways. Methyl donor deficiency produces liver steatosis and predisposes to metabolic syndrome. Whether impaired fatty acid oxidation contributes to this steatosis remains unknown.METHODS: We evaluated the consequences of methyl donor deficient diet in liver of pups from dams subjected to deficiency during gestation and lactation. RESULTS: The deprived rats had microvesicular steatosis, with increased triglycerides, decreased methionine synthase activity, S-adenosylmethionine, and S-adenosylmethionine/S-adenosylhomocysteine ratio. We observed no change in apoptosis markers, oxidant and reticulum stresses, and carnityl-palmitoyl transferase 1 activity, and a decreased expression of SREBP-1c. Impaired beta-oxidation of fatty acids and carnitine deficit were the predominant changes, with decreased free and total carnitines, increased C14:1/C16 acylcarnitine ratio, decrease of oxidation rate of palmitoyl-CoA and palmitoyl-L-carnitine and decrease of expression of novel organic cation transporter 1, acylCoA-dehydrogenase and trifunctional enzyme subunit alpha and decreased activity of complexes I and II. These changes were related to lower protein expression of ER-α, ERR-α and HNF-4α, and hypomethylation of PGC-1α co-activator that reduced its binding with PPAR-α, ERR-α, and HNF-4α. CONCLUSIONS: The liver steatosis resulted predominantly from hypomethylation of PGC1-α, decreased binding with its partners and subsequent impaired mitochondrial fatty acid oxidation. This link between methyl donor deficiency and epigenomic deregulations of energy metabolism opens new insights into the pathogenesis of fatty liver disease, in particular, in relation to the fetal programming hypothesis

    IL28B and IL10R -1087 polymorphisms are protective for chronic genotype 1 HCV infection and predictors of response to interferon-based therapy in an East-Central European cohort.

    Get PDF
    BACKGROUND: Previous studies have shown that single nucleotide polymorphisms (SNP) in IL28B and IL10R are associated with sustained virological response (SVR) in chronic hepatitis C patients treated with pegilated interferon plus ribavirin (P/R). The present study extends our earlier investigations on a large East-Central European cohort. The allele frequencies of IL28B and IL10R in genotype 1 HCV infection were compared with that of healthy controls for the purpose of examining the relationship between the polymorphisms and the SVR to P/R treatment. METHODS: A total of 748 chronic HCV1 infected patients (365 male, 383 female; 18-82 years) and 105 voluntary blood donors as controls were enrolled. Four hundred and twenty HCV patients were treated with P/R for 24-72 weeks, out of them 195 (46.4%) achieved SVR. The IL28 rs12979860 SNP was determined using Custom Taqman SNP Genotyping Assays. The IL10R -1087 (also known as IL10R -1082 (rs1800896) promoter region SNP was determined by RT-PCR and restriction fragment length polymorphism analysis. RESULTS: The IL28B CC genotype occurred with lower frequency in HCV patients than in controls (26.1% vs 51.4%, p<0.001). P/R treated patients with the IL28B CC genotype achieved higher SVR rate, as compared to patients with CT (58.6% vs 40.8%, p=0.002). The prevalence of IL10R -1087 GG genotype was lower in patients than in controls (31.8 % vs 52.2%, p<0.001). Among patients achieving SVR, the IL10R -1087 GG genotype occurred with higher frequency than the AA (32.0% vs 17.4%, p=0.013). The IL28B T allele plus IL10R A allele combination was found with higher prevalence in patients than in controls (52% vs 20.7%, p<0.001). The IL28B CC plus IL10R A allele combination occurred with higher frequency among patients with SVR than in non-responders (21.3% vs 12.8%, p=0.026). Both the IL28B CC plus IL10R GG and the IL28B CC plus IL10R A allele combinations occurred with lower frequency in patients than in controls. CONCLUSIONS: In our HCV1 patients, both the IL28B CC and IL10R GG genotypes are associated with clearance of HCV. Moreover, distinct IL28B and IL10R allele combinations appear to be protective against chronic HCV1 infection and predictors of response to P/R therapy

    Quality Indicators for Colonoscopy Procedures: A Prospective Multicentre Method for Endoscopy Units

    Get PDF
    BACKGROUND AND AIMS: Healthcare professionals are required to conduct quality control of endoscopy procedures, and yet there is no standardised method for assessing quality. The topic of the present study was to validate the applicability of the procedure in daily practice, giving physicians the ability to define areas for continuous quality improvement. METHODS: In ten endoscopy units in France, 200 patients per centre undergoing colonoscopy were enrolled in the study. An evaluation was carried out based on a prospectively developed checklist of 10 quality-control indicators including five dependent upon and five independent of the colonoscopy procedure. RESULTS: Of the 2000 procedures, 30% were done at general hospitals, 20% at university hospitals, and 50% in private practices. The colonoscopies were carried out for a valid indication for 95.9% (range 92.5-100). Colon preparation was insufficient in 3.7% (range 1-10.5). Colonoscopies were successful in 95.3% (range 81-99). Adenoma detection rate was 0.31 (range 0.17-0.45) in successful colonoscopies. CONCLUSION: This tool for evaluating the quality of colonoscopy procedures in healthcare units is based on standard endoscopy and patient criteria. It is an easy and feasible procedure giving the ability to detect suboptimal practice and differences between endoscopy-units. It will enable individual units to assess the quality of their colonoscopy techniques
    • 

    corecore