38 research outputs found

    Mossbauer and magnetization studies of amorphous NdFeB compositionally modulated thin films

    Get PDF
    Several NdFeB compositionally modulated thin films are studied by using both conversion electron Mossbauer spectra and SQUID (superconducting quantum-interference-device) magnetometry. Both the hyperfine fields and the easy magnetization magnitude are not correlated with the modulation characteristic length (lambda) while the magnetization perpendicular to the thin-film plane decreases as lambda increases. The spectra were recorded at room temperature being the gamma rays perpendicular to the substrate plane. The magnetization measurements were recorded by using a SHE SQUID magnetometer in applied magnetic fields up to 5.5 T and in the temperature range between 1.8 and 30 K

    Fabrication process of Mo/Au TES at RT

    Get PDF
    We report on the fabrication details of TES based on Mo/Au bilayers. The Mo layer is deposited by radio frequency (RF) sputtering and capped with a sputter deposited thin Au protection layer. Afterwards, a second Au layer of suitable (lower) resistivity is deposited ex‐situ by e‐beam evaporation, until completion of the total desired Au thickness. The deposition was performed at room temperature (RT) on LPCVD Si3 N4 membranes. Such a deposition procedure is very reproducible and allow controlling the critical temperature (Tc) and normal electrical resistance (RN ) of the Mo/Au bilayer. The process is optimized to achieve low stress bilayers, thus avoiding the undesirable curvature of the membranes. Bilayers are patterned using photolithographic techniques and wet etching procedures. Mo superconducting paths are used to contact the Mo/Au bilayers, thus ensuring good electrical conductivity and thermal isolation. The entire fabrication process let to stable and reproducible sensors with required and tunable functional propertie

    Thickness dependence of critical temperature in Mo/Au bilayers

    Get PDF
    We report on the sensitivity of the superconducting critical temperature (TC) to layer thickness, as well as on TC reproducibility in Mo/Au bilayers. Resistivity measurements on samples with a fixed Au thickness (dAu) and Mo thickness (dMo) ranging from 50 to 250 nm, and with a fixed dMo and different dAu thickness are shown. Experimental data are discussed in the framework of Martinis model, whose application to samples with dAu above their coherence length is analysed in detail. Results show a good coupling between normal and superconducting layers and excellent TC reproducibility, allowing to accurately correlate Mo layer thickness and bilayer TC

    Proyecto de prescripción de actividad física en pacientes con movilidad reducida y Diabetes Mellitus tipo dos

    Get PDF
    Tesis (Profesor de Educación Física para la Enseñanza Básica, Licenciado en Educación)El proyecto consiste en la elaboración de una batería de ejercicios enfocados en usuarios que padecen diabetes mellitus tipo dos y presentan movilidad reducida. Las carencias en cuanto a movilidad conllevan a que presenten altos niveles de sedentarismo, eso produce como resultado una disminución en el uso de insulina disponible en sangre. El propósito del proyecto es mejorar la calidad de vida de las personas mediante ejercicios físicos guiados, que posibiliten la disminución del sedentarismo. Conjuntamente se manejará una estrategia que se utilizará para motivar a los pacientes a la realización del proyecto constara con charlas explicativas y motivacionales una vez cada dos semanas, adicional a esto se les entregarán sus resultados del hemoglucotest para que durante cada sesión vayan comprobando sus mejoras tras el ejercicio. El proyecto tiene una duración de 15 semanas durante las cuales se intervendrá a los sujetos, la intervención se realizará 3 días por semana, con una duración de 45 minutos cada sesión. Este proyecto tendrá como costo $1.983.345, su financiamiento será proporcionado por cada estudiante significando esto un 38,7% del gasto, el equipamiento de salud será solventado por el establecimiento de salud equivalente al 61,3% de los gastos total

    Characterization of a Mo/Au thermometer for ATHENA

    Get PDF
    The first dark characterization of a thermometer fabricated with our Mo/Au bilayers to be used as a transition edge sensor is presented. High-quality, stress-free Mo layers, whose thickness is used to tune the critical temperature (TC ) down to 100 mK, are deposited by sputtering at room temperature (RT ) on Si3N4 bulk and membranes, and protected from degradation with a 15-nm sputtered Au layer. An extra layer of high-quality Au is deposited by ex situ e-beam to ensure low residual resistance. The thermometer is patterned on a membrane using standard photolithographic techniques and wet etching processes, and is contacted through Mo paths, displaying a sharp superconducting transition (α ≈ 600). Results show a good coupling between Mo and Au layers and excellent TC reproducibility, allowing to accurately correlate dM o and TC . Since dAu is bigger than ξM for all analyzed samples, bilayer residual resistance can be modified without affecting TC . Finally, first current to voltage measurements at different temperatures are measured and analyzed, obtaining the corresponding characterization parameters

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist’s perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of cen‑ tral tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfed in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores>70/100 from the frst procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score

    Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies : a multicenter study in 21 Spanish pulmonology services

    Get PDF
    Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images

    EURECA: European-Japanese microcalorimeter array

    Get PDF
    The EURECA project aims to demonstrate technological readiness of a micro-calorimeter array for application in future X-ray astronomy missions, like Constellation-X, EDGE, and XEUS. The prototype instrument consists of a 5 × 5 pixel array of TES-based micro-calorimeters read out by two SQUID-amplifier channels using frequency-domain-multiplexing (FDM) with digital base-band feedback. The detector array is cooled by a cryogen-free cryostat consisting of a pulse tube cooler and a two stage ADR. Initial tests of the system at the PTB beam line of the BESSY synchrotron showed stable performance and an X-ray energy resolution of 1.5 eV at 250 eV for read-out of one TES-pixel only. Next step is deployment of FDM to read-out the full array. Full performance demonstration is expected end 2008.This work was financially supported by the Dutch Organization for Scientific Research (NWO).Peer Reviewe

    Mossbauer studies of amorphous FeSi compositionally modulated thin films

    Get PDF
    Conversion electron Mossbauer spectra of composition modulated FeSi thin films have been analysed within the framework of a quasi shape independent model in which the distribution function for the hyperfine fields is assumed to be given by a binomial distribution. Both the hyperfine field and the hyperfine field distribution depend on the modulation characteristic length
    corecore