229 research outputs found

    Quantum controlled phase gate and cluster states generation via two superconducting quantum interference devices in a cavity

    Get PDF
    A scheme for implementing 2-qubit quantum controlled phase gate (QCPG) is proposed with two superconducting quantum interference devices (SQUIDs) in a cavity. The gate operations are realized within the two lower flux states of the SQUIDs by using a quantized cavity field and classical microwave pulses. Our scheme is achieved without any type of measurement, does not use the cavity mode as the data bus and only requires a very short resonant interaction of the SQUID-cavity system. As an application of the QCPG operation, we also propose a scheme for generating the cluster states of many SQUIDs.Comment: 4 pages, resumitte

    Gas capture processes

    Get PDF
    Copyright © 2020 by the authors. The increasing trends in gas emissions have had direct adverse impacts on human health and ecological habitats in the world. A variety of technologies have been deployed to mitigate the release of such gases, including CO2, CO, SO2, H2S, NOx and H2. This special issue on gas-capture processes collects 25 review and research papers on the applications of novel techniques, processes, and theories in gas capture and removal

    Cancer treatment-related neuropathic pain:proof of concept study with menthol—a TRPM8 agonist

    Get PDF
    PURPOSE: Effective treatment of neuropathic pain without unacceptable side effects is challenging. Cancer sufferers increasingly live with long-term treatment-related neuropathic pain, resulting from chemotherapy-induced peripheral neuropathy (CIPN) or surgical scars. This proof-of-concept study aimed to determine whether preclinical evidence for TRPM8 ion channels in sensory neurons as a novel analgesic target could be translated to clinical benefit in patients with neuropathic pain, using the TRPM8 activator menthol. PATIENTS AND METHODS: Patients with problematic treatment-related neuropathic pain underwent a baseline assessment using validated questionnaires, psychophysical testing, and objective functional measures. The painful area was treated with topical 1 % menthol cream twice daily. Assessments were repeated at 4–6 weeks. The primary outcome was the change in Brief Pain Inventory total scores at 4–6 weeks. Secondary outcomes included changes in function, mood and skin sensation. RESULTS: Fifty-one patients (female/male, 32/19) were recruited with a median age of 61 (ranging from 20 to 89). The commonest aetiology was CIPN (35/51), followed by scar pain (10/51). Thirty-eight were evaluable on the primary outcome. Eighty-two per cent (31/38) had an improvement in total Brief Pain Inventory scores (median, 47 (interquartile range, 30 to 64) to 34 (6 to 59), P < 0.001). Improvements in mood (P = 0.0004), catastrophising (P = 0.001), walking ability (P = 0.008) and sensation (P < 0.01) were also observed. CONCLUSION: This proof-of-concept study indicates that topical menthol has potential as a novel analgesic therapy for cancer treatment-related neuropathic pain. Improvements in patient-rated measures are supported by changes in objective measures of physical function and sensation. Further systematic evaluation of efficacy is required

    Anomalous J/ψJ/\psi suppression in Pb-Pb interactions at 158 GeV per nucleon

    Get PDF
    The Drell-Yan and J/psi cross-sections measured in Pb-Pb collisions are compared with the values extrapolated from the results obtained in proton and light ion induced reactions. While the Drell-Yan production exhibits the normal expected behaviour, the yield of J/psi in Pb-Pb interactions is abnormally low, as it lies 9 standard deviations below the expected value. Moreover, the departure from the expected behaviour increases significantly from peripheral to central collisions. (C) 1997 Elsevier Science B.V

    Semiconductor Spintronics

    Full text link
    Spintronics refers commonly to phenomena in which the spin of electrons in a solid state environment plays the determining role. In a more narrow sense spintronics is an emerging research field of electronics: spintronics devices are based on a spin control of electronics, or on an electrical and optical control of spin or magnetism. This review presents selected themes of semiconductor spintronics, introducing important concepts in spin transport, spin injection, Silsbee-Johnson spin-charge coupling, and spindependent tunneling, as well as spin relaxation and spin dynamics. The most fundamental spin-dependent nteraction in nonmagnetic semiconductors is spin-orbit coupling. Depending on the crystal symmetries of the material, as well as on the structural properties of semiconductor based heterostructures, the spin-orbit coupling takes on different functional forms, giving a nice playground of effective spin-orbit Hamiltonians. The effective Hamiltonians for the most relevant classes of materials and heterostructures are derived here from realistic electronic band structure descriptions. Most semiconductor device systems are still theoretical concepts, waiting for experimental demonstrations. A review of selected proposed, and a few demonstrated devices is presented, with detailed description of two important classes: magnetic resonant tunnel structures and bipolar magnetic diodes and transistors. In most cases the presentation is of tutorial style, introducing the essential theoretical formalism at an accessible level, with case-study-like illustrations of actual experimental results, as well as with brief reviews of relevant recent achievements in the field.Comment: tutorial review; 342 pages, 132 figure

    Call to Action: SARS-CoV-2 and CerebrovAscular DisordErs (CASCADE)

    Get PDF
    Background and purpose: The novel severe acute respiratory syndrome coronavirus 2 (SARS-Cov-2), now named coronavirus disease 2019 (COVID-19), may change the risk of stroke through an enhanced systemic inflammatory response, hypercoagulable state, and endothelial damage in the cerebrovascular system. Moreover, due to the current pandemic, some countries have prioritized health resources towards COVID-19 management, making it more challenging to appropriately care for other potentially disabling and fatal diseases such as stroke. The aim of this study is to identify and describe changes in stroke epidemiological trends before, during, and after the COVID-19 pandemic. Methods: This is an international, multicenter, hospital-based study on stroke incidence and outcomes during the COVID-19 pandemic. We will describe patterns in stroke management, stroke hospitalization rate, and stroke severity, subtype (ischemic/hemorrhagic), and outcomes (including in-hospital mortality) in 2020 during COVID-19 pandemic, comparing them with the corresponding data from 2018 and 2019, and subsequently 2021. We will also use an interrupted time series (ITS) analysis to assess the change in stroke hospitalization rates before, during, and after COVID-19, in each participating center. Conclusion: The proposed study will potentially enable us to better understand the changes in stroke care protocols, differential hospitalization rate, and severity of stroke, as it pertains to the COVID-19 pandemic. Ultimately, this will help guide clinical-based policies surrounding COVID-19 and other similar global pandemics to ensure that management of cerebrovascular comorbidity is appropriately prioritized during the global crisis. It will also guide public health guidelines for at-risk populations to reduce risks of complications from such comorbidities. © 202
    corecore