301 research outputs found

    Overview of the design of the ITER heating neutral beam injectors

    Get PDF
    The heating neutral beam injectors (HNBs) of ITER are designed to deliver 16.7MWof 1 MeVD0 or 0.87 MeVH0 to the ITER plasma for up to 3600 s. They will be the most powerful neutral beam\uf0a0(NB) injectors ever, delivering higher energy NBs to the plasma in a tokamak for longer than any previous systems have done. The design of the HNBs is based on the acceleration and neutralisation of negative ions as the efficiency of conversion of accelerated positive ions is so low at the required energy that a realistic design is not possible, whereas the neutralisation ofH 12 andD 12 remains acceptable ( 4856%). The design of a long pulse negative ion based injector is inherently more complicated than that of short pulse positive ion based injectors because: \u2022 negative ions are harder to create so that they can be extracted and accelerated from the ion source; \u2022 electrons can be co-extracted from the ion source along with the negative ions, and their acceleration must be minimised to maintain an acceptable overall accelerator efficiency; \u2022 negative ions are easily lost by collisions with the background gas in the accelerator; \u2022 electrons created in the extractor and accelerator can impinge on the extraction and acceleration grids, leading to high power loads on the grids; \u2022 positive ions are created in the accelerator by ionisation of the background gas by the accelerated negative ions and the positive ions are back-accelerated into the ion source creating a massive power load to the ion source; \u2022 electrons that are co-accelerated with the negative ions can exit the accelerator and deposit power on various downstream beamline components. The design of the ITER HNBs is further complicated because ITER is a nuclear installation which will generate very large fluxes of neutrons and gamma rays. Consequently all the injector components have to survive in that harsh environment. Additionally the beamline components and theNBcell, where the beams are housed, will be activated and all maintenance will have to be performed remotely. This paper describes the design of theHNBinjectors, but not the associated power supplies, cooling system, cryogenic system etc, or the high voltage bushingwhich separates the vacuum of the beamline fromthehighpressureSF6 of the high voltage (1MV) transmission line, through which the power, gas and coolingwater are supplied to the beam source. Also themagnetic field reduction system is not described

    Vasoprotective effects of human CD34+ cells: towards clinical applications

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The development of cell-based therapeutics for humans requires preclinical testing in animal models. The use of autologous animal products fails to address the efficacy of similar products derived from humans. We used a novel immunodeficient rat carotid injury model in order to determine whether human cells could improve vascular remodelling following acute injury.</p> <p>Methods</p> <p>Human CD34+ cells were separated from peripheral buffy coats using automatic magnetic cell separation. Carotid arterial injury was performed in male Sprague-Dawley nude rats using a 2F Fogarty balloon catheter. Freshly harvested CD34+ cells or saline alone was administered locally for 20 minutes by endoluminal instillation. Structural and functional analysis of the arteries was performed 28 days later.</p> <p>Results</p> <p>Morphometric analysis demonstrated that human CD34+ cell delivery was associated with a significant reduction in intimal formation 4 weeks following balloon injury as compared with saline (I/M ratio 0.79 Β± 0.18, and 1.71 Β± 0.18 for CD34, and saline-treated vessels, respectively P < 0.05). Vasoreactivity studies showed that maximal relaxation of vessel rings from human CD34+ treated animals was significantly enhanced compared with saline-treated counterparts (74.1 Β± 10.2, and 36.8 Β± 12.1% relaxation for CD34+ cells and saline, respectively, P < 0.05)</p> <p>Conclusion</p> <p>Delivery of human CD34+ cells limits neointima formation and improves arterial reactivity after vascular injury. These studies advance the concept of cell delivery to effect vascular remodeling toward a potential human cellular product.</p

    Start of SPIDER operation towards ITER neutral beams

    Get PDF
    Heating Neutral Beam (HNB) Injectors will constitute the main plasma heating and current drive tool both in ITER and JT60-SA, which are the next major experimental steps for demonstrating nuclear fusion as viable energy source. In ITER, in order to achieve the required thermonuclear fusion power gain Q=10 for short pulse operation and Q=5 for long pulse operation (up to 3600s), two HNB injectors will be needed [1], each delivering a total power of about 16.5 MW into the magnetically-confined plasma, by means of neutral hydrogen or deuterium particles having a specific energy of about 1 MeV. Since only negatively charged particles can be efficiently neutralized at such energy, the ITER HNB injectors [2] will be based on negative ions, generated by caesium-catalysed surface conversion of atoms in a radio-frequency driven plasma source. A negative deuterium ion current of more than 40 A will be extracted, accelerated and focused in a multi-aperture, multi-stage electrostatic accelerator, having 1280 apertures (~ 14 mm diam.) and 5 acceleration stages (~200 kV each) [3]. After passing through a narrow gas-cell neutralizer, the residual ions will be deflected and discarded, whereas the neutralized particles will continue their trajectory through a duct into the tokamak vessels to deliver the required heating power to the ITER plasma for a pulse duration of about 3600 s. Although the operating principles and the implementation of the most critical parts of the injector have been tested in different experiments, the ITER NBI requirements have never been simultaneously attained. In order to reduce the risks and to optimize the design and operating procedures of the HNB for ITER, a dedicated Neutral Beam Test Facility (NBTF) [4] has been promoted by the ITER Organization with the contribution of the European Union\u2019s Joint Undertaking for ITER and of the Italian Government, with the participation of the Japanese and Indian Domestic Agencies (JADA and INDA) and of several European laboratories, such as IPP-Garching, KIT-Karlsruhe, CCFE-Culham, CEA-Cadarache. The NBTF, nicknamed PRIMA, has been set up at Consorzio RFX in Padova, Italy [5]. The planned experiments will verify continuous HNB operation for one hour, under stringent requirements for beam divergence (< 7 mrad) and aiming (within 2 mrad). To study and optimise HNB performances, the NBTF includes two experiments: MITICA, full-scale NBI prototype with 1 MeV particle energy and SPIDER, with 100 keV particle energy and 40 A current, aiming at testing and optimizing the full-scale ion source. SPIDER will focus on source uniformity, negative ion current density and beam optics. In June 2018 the experimental operation of SPIDER has started

    Early Detection, Diagnosis and Intervention Services for Young Children with Autism Spectrum Disorder in the European Union (ASDEU): Family and Professional Perspectives

    Get PDF
    Early services for ASD need to canvas the opinions of both parents and professionals. These opinions are seldom compared in the same research study. This study aims to ascertain the views of families and professionals on early detection, diagnosis and intervention services for young children with ASD. An online survey compiled and analysed data from 2032 respondents across 14 European countries (60.9% were parents; 39.1% professionals). Using an ordinal scale from 1 to 7, parents’ opinions were more negative (mean = 4.6; SD 2.2) compared to those of professionals (mean = 4.9; SD 1.5) when reporting satisfaction with services. The results suggest services should take into account child’s age, delays in accessing services, and active stakeholders’ participation when looking to improve services

    Intervention Services for Autistic Adults: An ASDEU Study of Autistic Adults, Carers, and Professionals' Experiences

    Get PDF
    The Autism Spectrum Disorders in the European Union (ASDEU) survey investigated local services' use experiences of autistic adults, carers and professionals with interventions for autistic adults. The majority of the 697 participants experienced recommended considerations prior to deciding on intervention and during the intervention plan and implementation. Psychosocial interventions were the most commonly experienced interventions, while pharmacological interventions NOT recommended for core autistic symptoms were reported by fairly large proportions of participants. Family interventions were experienced slightly more commonly by carers than adults or professionals. Less than the 26% of autistic adult responders who had experienced challenging behaviors reported receiving an intervention to change them. These results provide insights for improving gaps in service provision of interventions among autistic adults.Peer reviewe

    Model for screening of resonant magnetic perturbations by plasma in a realistic tokamak geometry and its impact on divertor strike points

    Full text link
    This work addresses the question of the relation between strike-point splitting and magnetic stochasticity at the edge of a poloidally diverted tokamak in the presence of externally imposed magnetic perturbations. More specifically, ad-hoc helical current sheets are introduced in order to mimic a hypothetical screening of the external resonant magnetic perturbations by the plasma. These current sheets, which suppress magnetic islands, are found to reduce the amount of splitting expected at the target, which suggests that screening effects should be observable experimentally. Multiple screening current sheets reinforce each other, i.e. less current relative to the case of only one current sheet is required to screen the perturbation.Comment: Accepted in the Proceedings of the 19th International Conference on Plasma Surface Interactions, to be published in Journal of Nuclear Materials. Version 2: minor formatting and text improvements, more results mentioned in the conclusion and abstrac

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    Changes in Body Weight and Psychotropic Drugs: A Systematic Synthesis of the Literature

    Get PDF
    <div><h3>Introduction</h3><p>Psychotropic medication use is associated with weight gain. While there are studies and reviews comparing weight gain for psychotropics within some classes, clinicians frequently use drugs from different classes to treat psychiatric disorders.</p> <h3>Objective</h3><p>To undertake a systematic review of all classes of psychotropics to provide an all encompassing evidence-based tool that would allow clinicians to determine the risks of weight gain in making both intra-class and interclass choices of psychotropics.</p> <h3>Methodology and Results</h3><p>We developed a novel hierarchical search strategy that made use of systematic reviews that were already available. When such evidence was not available we went on to evaluate randomly controlled trials, followed by cohort and other clinical trials, narrative reviews, and, where necessary, clinical opinion and anecdotal evidence. The data from the publication with the highest level of evidence based on our hierarchical classification was presented. Recommendations from an expert panel supplemented the evidence used to rank these drugs within their respective classes. Approximately 9500 articles were identified in our literature search of which 666 citations were retrieved. We were able to rank most of the psychotropics based on the available evidence and recommendations from subject matter experts. There were few discrepancies between published evidence and the expert panel in ranking these drugs.</p> <h3>Conclusion</h3><p>Potential for weight gain is an important consideration in choice of any psychotropic. This tool will help clinicians select psychotropics on a case-by-case basis in order to minimize the impact of weight gain when making both intra-class and interclass choices.</p> </div

    Autistic Adult Services Availability, Preferences, and User Experiences: Results From the Autism Spectrum Disorder in the European Union Survey

    Get PDF
    There is very little knowledge regarding autistic adult services, practices, and delivery. The study objective was to improve understanding of current services and practices for autistic adults and opportunities for improvement as part of the Autism Spectrum Disorder in the European Union (ASDEU) project. Separate survey versions were created for autistic adults, carers of autistic adults, and professionals in adult services. 2,009 persons responded to the survey and 1,085 (54%) of them completed at least one of the services sections: 469 autistic adults (65% female; 55% 50% responded "don't know"). Five of seven residential services features recommended for autistic adults were experienced by <50% of adults. The knowledge of good local services models that work well for autistic adults was generally low across all services areas. The variation in services experiences and perceptions reported by autistic adults, carers, or professionals underscore the need to query all groups for a complete picture of community services availability and needs. The results showed areas for potential improvement in autistic adult services delivery in the EU to achieve recommended standards
    • …
    corecore