1,821 research outputs found

    Controlled delivery of membrane proteins to artificial lipid bilayers by nystatin-ergosterol modulated vesicle fusion

    No full text
    The study of ion channels and other membrane proteins and their potential use as biosensors and drug screening targets require their reconstitution in an artificial membrane. These applications would greatly benefit from microfabricated devices in which stable artificial lipid bilayers can be rapidly and reliably formed. However, the amount of protein delivered to the bilayer must be carefully controlled. A vesicle fusion technique is investigated where composite ion channels of the polyene antibiotic nystatin and the sterol ergosterol are employed to render protein-carrying vesicles fusogenic After fusion with an ergosterol-free artificial bilayer the nystatin-ergosterol channels do not dissociate immediately and thus cause a transient current signal that marks the vesicle fusion event. Experimental pitfalls of this method were identified, the influence of the nystatin and ergosterol concentration on the fusion rate and the shape of the fusion event marker was explored, and the number of different lipid was reduced. Under these conditions, the B-amyloid peptide could be delivered in a controlled manner to a standard planar bilayer. Additionally, the electrical recordings were obtained of vesicles fusing with a planar lipid bilayer in a microfabricated device, demonstrating the suitability of nystatin-ergosterol modulated vesicle fusion for protein delivery within microsystems

    2D-Based 3D Volume Retrieval Using Singular Value Decomposition of Detected Regions

    Get PDF
    In this paper, a novel 3D retrieval model to retrieve medical volumes using 2D images as input is proposed. The main idea consists of applying a multi–scale detection of saliency of image regions. Then, the 3D volumes with the regions for each of the scales are associated with a set of projections onto the three canonical planes. The 3D shape is indirectly represented by a 2D–shape descriptor so that the 3D–shape matching is transformed into measuring similarity between 2D–shapes. The shape descriptor is defined by the set of the k largest singular values of the 2D images and Euclidean distance between the vector descriptors is used as a similarity measure. The preliminary results obtained on a simple database show promising performance with a mean average precision (MAP) of 0.82 and could allow using the approach as part of a retrieval system in clinical routine

    Characterization of Shewanella oneidensis MtrC: a cell-surface decaheme cytochrome involved in respiratory electron transport to extracellular electron acceptors

    Get PDF
    MtrC is a decaheme c-type cytochrome associated with the outer cell membrane of Fe(III)-respiring species of the Shewanella genus. It is proposed to play a role in anaerobic respiration by mediating electron transfer to extracellular mineral oxides that can serve as terminal electron acceptors. The present work presents the first spectropotentiometric and voltammetric characterization of MtrC, using protein purified from Shewanella oneidensis MR-1. Potentiometric titrations, monitored by UV–vis absorption and electron paramagnetic resonance (EPR) spectroscopy, reveal that the hemes within MtrC titrate over a broad potential range spanning between approximately +100 and approximately -500 mV (vs. the standard hydrogen electrode). Across this potential window the UV–vis absorption spectra are characteristic of low-spin c-type hemes and the EPR spectra reveal broad, complex features that suggest the presence of magnetically spin-coupled low-spin c-hemes. Non-catalytic protein film voltammetry of MtrC demonstrates reversible electrochemistry over a potential window similar to that disclosed spectroscopically. The voltammetry also allows definition of kinetic properties of MtrC in direct electron exchange with a solid electrode surface and during reduction of a model Fe(III) substrate. Taken together, the data provide quantitative information on the potential domain in which MtrC can operate

    Wideband THz time domain spectroscopy based on optical rectification and electro-optic sampling

    Get PDF
    We present an analytical model describing the full electromagnetic propagation in a THz time-domain spectroscopy (THz-TDS) system, from the THz pulses via Optical Rectification to the detection via Electro Optic-Sampling. While several investigations deal singularly with the many elements that constitute a THz-TDS, in our work we pay particular attention to the modelling of the time-frequency behaviour of all the stages which compose the experimental set-up. Therefore, our model considers the following main aspects: (i) pump beam focusing into the generation crystal; (ii) phase-matching inside both the generation and detection crystals; (iii) chromatic dispersion and absorption inside the crystals; (iv) Fabry-Perot effect; (v) diffraction outside, i.e. along the propagation, (vi) focalization and overlapping between THz and probe beams, (vii) electro-optic sampling. In order to validate our model, we report on the comparison between the simulations and the experimental data obtained from the same set-up, showing their good agreement

    Assessment of strategies for switching patients from olanzapine to risperidone: A randomized, open-label, rater-blinded study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In clinical practice, physicians often need to change the antipsychotic medications they give to patients because of an inadequate response or the presence of unacceptable or unsafe side effects. However, there is a lack of consensus in the field as to the optimal switching strategy for antipsychotics, especially with regards to the speed at which the dose of the previous antipsychotic should be reduced. This paper assesses the short-term results of strategies for the discontinuation of olanzapine when initiating risperidone.</p> <p>Methods</p> <p>In a 6-week, randomized, open-label, rater-blinded study, patients with schizophrenia or schizoaffective disorder, on a stable drug dose for more than 30 days at entry, who were intolerant of or exhibiting a suboptimal symptom response to more than 30 days of olanzapine treatment, were randomly assigned to the following switch strategies (common risperidone initiation scheme; varying olanzapine discontinuation): (i) abrupt strategy, where olanzapine was discontinued at risperidone initiation; (ii) gradual 1 strategy, where olanzapine was given at 50% entry dose for 1 week after risperidone initiation and then discontinued; or (iii) gradual 2 strategy, where olanzapine was given at 100% entry dose for 1 week, then at 50% in the second week, and then discontinued.</p> <p>Results</p> <p>The study enrolled 123 patients on stable doses of olanzapine. Their mean age was 40.3 years and mean (± standard deviation (SD)) baseline Positive and Negative Syndrome Scale (PANSS) total score of 75.6 ± 11.5. All-cause treatment discontinuation was lowest (12%) in the group with the slowest olanzapine dose reduction (gradual 2) and occurred at half the discontinuation rate in the other two groups (25% in abrupt and 28% in gradual 1). The relative risk of early discontinuation was 0.77 (confidence interval 0.61–0.99) for the slowest dose reduction compared with the other two strategies. After the medication was changed, improvements at endpoint were seen in PANSS total score (-7.3; <it>p </it>< 0.0001) and in PANSS positive (-3.0; <it>p </it>< 0.0001), negative (-0.9; <it>p </it>= 0.171) and anxiety/depression (-1.4; <it>p </it>= 0.0005) subscale scores. Severity of movement disorders and weight changes were minimal.</p> <p>Conclusion</p> <p>When switching patients from olanzapine to risperidone, a gradual reduction in the dose of olanzapine over 2 weeks was associated with higher rates of retention compared with abrupt or less gradual discontinuation. Switching via any strategy was associated with significant improvements in positive and anxiety symptoms and was generally well tolerated.</p> <p>Trial registration</p> <p>ClinicalTrials.gov NCT00378183</p

    Pre-surgical radiologic identification of peri-prosthetic osteolytic lesions around TKRs: a pre-clinical investigation of diagnostic accuracy

    Get PDF
    Background: Emerging longitudinal data appear to demonstrate an alarming trend towards an increasing prevalence of osteolysis-induced mechanical failure, following total knee replacement (TKR). Even with high-quality multi-plane X-rays, accurate pre-surgical evaluation of osteolytic lesions is often difficult. This is likely to have an impact on surgical management and provides reasonable indication for the development of a model allowing more reliable lesion assessment. The aim of this study, using a simulated cadaver model, was to explore the accuracy of rapid spiral computed tomography (CT) examination in the non-invasive evaluation of peri-prosthetic osteolytic lesions, secondary to TKR, and to compare this to conventional X-ray standards. Methods: A series of nine volume-occupying defects, simulating osteolytic lesions, were introduced into three human cadaveric knees, adjacent to the TKR implant components. With implants in situ, each knee was imaged using a two-stage conventional plain X-ray series and rapid-acquisition spiral CT. A beam-hardening artefact removal algorithm was employed to improve CT image quality. After random image sorting, 12 radiologists were independently shown the series of plain X-ray images and asked to note the presence, anatomic location and 'size' of osteolytic lesions observed. The same process was repeated separately for review of the CT images. The corresponding X-ray and CT responses were directly compared to elicit any difference in the ability to demonstrate the presence and size of osteolytic lesions. Results: Access to CT images significantly improved the accuracy of recognition of peri-prosthetic osteolytic lesions when compared to AP and lateral projections alone (P = 0.008) and with the addition of bi-planar oblique X-rays (P = 0.03). No advantage was obtained in accuracy of identification of such lesions through the introduction of the oblique images when compared with the AP and lateral projections alone (P = 0.13) Conclusion: The findings of this study suggest that peri-prosthetic osteolytic lesions can be reliably described non-invasively using a simple, rapid-acquisition CT-based imaging approach. The low sensitivity of conventional X-ray, even with provision of supplementary bi-planar 45° oblique views, suggests a limited role for use in situ for TKR implant screening where peri-prosthetic osteolytic lesions are clinically suspected. In contrast, the accuracy of CT evaluation, linked to its procedural ease and widespread availability, may provide a more accurate way of evaluating osteolysis around TKRs, at routine orthopaedic follow up. These findings have direct clinical relevance, as accurate early recognition and classification of such lesions influences the timing and aggressiveness of surgical and non-operative management strategies, and also the nature and appropriateness of planned implant revision or joint-salvaging osteotomy procedures.Timothy P. Kurmis, Andrew P. Kurmis, David G. Campbell and John P. Slavotine

    Effect of pre-milking teat preparation procedures on the microbial count on teats prior to cluster application

    Get PDF
    A study was carried out to investigate the effect of six pre-milking teat preparation procedures on lowering the staphylococal, streptococcal and coliform microbial count on teat skin prior to cluster application. The teat preparations included 'Iodine', 'Chlorhexidine' teat foam, 'Washing and drying' with paper, 'No preparation', 'Chlorine' teat foam, and disinfectant 'Wipes'. Teat preparations were applied for five days to 10 cows for each treatment during two herd management periods (indoors and outdoors). Teats were swabbed on day four and five before teat preparation and repeated after teat preparation. The swabs were plated on three selective agars: Baird Parker (Staphylococcus spp.), Edwards (Streptococcus spp.), and MacConkey (coliform). Following incubation, microbial counts for each pathogen type were manually counted and assigned to one of six categories depending on the microbial counts measured. The results were analysed by logistic regression using SAS [28]. The main analysis was conducted on binary improvement scores for the swabbing outcomes. There were no differences for staphylococcal, streptococcal and coliform bacterial counts between treatments, measured 'before' teat preparation. Treatments containing 'Chlorhexidine' teat foam (OR = 4.46) and 'Wipes' (OR = 4.46) resulted in a significant reduction (P < 0.01) in the staphylococcal count on teats compared to 'Washing and drying' or 'No preparation'. 'Chlorine' teat foam (OR = 3.45) and 'Wipes' (3.45) had the highest probability (P < 0.01) of reducing streptococcal counts compared to 'Washing and drying' or 'No preparation'. There was no statistical difference between any of the disinfectant treatments applied in reducing coliforms. Thus, the use of some disinfectant products for pre-milking teat preparation can have beneficial effects on reducing the levels of staphylococcal and streptococcal pathogens on teat skin

    The six-minute walk test in community dwelling elderly: influence of health status.

    Get PDF
    BACKGROUND: The 6 minutes walk test (6MWT) is a useful assessment instrument for the exercise capacity of elderly persons. The impact of the health status on the 6MWT-distance in elderly, however, remains unclear, reducing its value in clinical settings. The objective of this study was to investigate to what extent the 6MWT-distance in community dwelling elderly is determined by health conditions. METHODS: One hundred and fifty-six community dwelling elderly people (53 male, 103 female) were assessed for health status and performed the 6MWT. After clinical evaluation, electrocardiography and laboratory examination participants were categorized into a stratified six-level classification system according to their health status, going from A (completely healthy) to D (signs of active disease at the moment of examination). RESULTS: The mean 6MWT-distance was 603 m (SD = 178). The 6MWT-distance decreased significantly with increasing age (ANOVA p = 0.0001) and with worsening health status (ANCOVA, corrected for age p < 0.001). A multiple linear regression model with health status, age and gender as independent variables explained 31% of the 6MWT-distance variability. Anthropometrical measures (stature, weight and BMI) did not significantly improve the prediction model. A significant relationship between 6MWT-distance and stature was only present in category A (completely healthy). CONCLUSIONS: Significant differences in 6MWT-distance are observed according to health status in community-dwelling elderly persons. The proposed health categorizing system for elderly people is able to distinguish persons with lower physical exercise capacity and can be useful when advising physical trainers for seniors

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore