8 research outputs found

    Real-world performance and accuracy of stress echocardiography: The EVAREST observational multi-centre study

    Get PDF
    Aims - Stress echocardiography is widely used to identify obstructive coronary artery disease. High accuracy is reported in expert hands but is dependent on operator training and image quality. The EVAREST study provides UK-wide data to evaluate real-world performance and accuracy of stress echocardiography. Methods and Results - Participants undergoing stress echocardiography for coronary artery disease were recruited from 31 hospitals. Participants were followed up through health records which underwent expert adjudication. Cardiac outcome was defined as anatomically or functionally-significant stenosis on angiography, revascularisation, medical management of ischaemia, acute coronary syndrome or cardiac-related death within six months. 5131 patients (55% male) participated with a median age of 65 years (IQR 57 – 74). 72.9% of studies used dobutamine and 68.5% were contrast studies. Inducible ischaemia was present in 19.3% of scans. Sensitivity and specificity for prediction of a cardiac outcome were 95.4% and 96.0%, respectively, with an accuracy of 95.9%. Sub-group analysis revealed high levels of predictive accuracy across a wide range of patient and protocol sub-groups, with the presence of a resting regional wall motion abnormalitiy significantly reducing the performance of both dobutamine (p<0.01) and exercise (p<0.05) stress echocardiography (p<0.05). Overall accuracy remained consistently high across all participating hospitals. Conclusion – Stress echocardiography has high accuracy across UK-based hospitals and thus indicates stress echocardiography is being delivered effectively in real-world practice, reinforcing its role as a first-line investigation in the assessment of patients with stable chest pain

    Real world hospital costs following stress echocardiography in the UK: a costing study from the EVAREST/BSE-NSTEP multi-centre study

    Get PDF
    Background: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identified key factors that affect costs to help inform future clinical planning and guidelines. Methods: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. Results: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with significant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384–1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. Conclusion: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to reflect actual value for money and support realistic planning

    Real-world performance and accuracy of stress echocardiography: the EVAREST observational multi-centre study

    No full text
    Aims Stress echocardiography is widely used to identify obstructive coronary artery disease (CAD). High accuracy is reported in expert hands but is dependent on operator training and image quality. The EVAREST study provides UK-wide data to evaluate real-world performance and accuracy of stress echocardiography. Methods and results Participants undergoing stress echocardiography for CAD were recruited from 31 hospitals. Participants were followed up through health records which underwent expert adjudication. Cardiac outcome was defined as anatomically or functionally significant stenosis on angiography, revascularization, medical management of ischaemia, acute coronary syndrome, or cardiac-related death within 6 months. A total of 5131 patients (55% male) participated with a median age of 65 years (interquartile range 57–74). 72.9% of studies used dobutamine and 68.5% were contrast studies. Inducible ischaemia was present in 19.3% of scans. Sensitivity and specificity for prediction of a cardiac outcome were 95.4% and 96.0%, respectively, with an accuracy of 95.9%. Sub-group analysis revealed high levels of predictive accuracy across a wide range of patient and protocol sub-groups, with the presence of a resting regional wall motion abnormalitiy significantly reducing the performance of both dobutamine (P < 0.01) and exercise (P < 0.05) stress echocardiography. Overall accuracy remained consistently high across all participating hospitals. Conclusion Stress echocardiography has high accuracy across UK-based hospitals and thus indicates stress echocardiography is being delivered effectively in real-world practice, reinforcing its role as a first-line investigation in the assessment of patients with stable chest pain
    corecore