358 research outputs found
Systematic trends in beta-delayed particle emitting nuclei: The case of beta-p-alpha emission from 21Mg
We have observed beta+-delayed alpha and p-alpha emission from the
proton-rich nucleus 21Mg produced at the ISOLDE facility at CERN. The
assignments were cross-checked with a time distribution analysis. This is the
third identified case of beta-p-alpha emission. We discuss the systematic of
beta-delayed particle emission decays, show that our observed decays fit
naturally into the existing pattern, and argue that the patterns are to a large
extent caused by odd-even effects.Comment: 6 pages, 5 figure
Recommended from our members
Heparin versus 0.9% sodium chloride locking for prevention of occlusion in central venous catheters in adults
Background
Intermittent locking of central venous catheters (CVCs) is undertaken to help maintain their patency. There are systematic variations in care: some practitioners use heparin (at different concentrations), whilst others use 0.9% NaCl (normal saline). This review looks at the effectiveness and safety of intermittent locking with heparin compared to 0.9% NaCl to see if the evidence establishes whether one is better than the other. This work is an update of a review first published in 2014.
Objectives
To assess the effectiveness and safety of intermittent locking of CVCs with heparin versus normal saline (NS) in adults to prevent occlusion.
Search methods
The Cochrane Vascular Information Specialist (CIS) searched the Specialised Register (last searched 11 June 2018) and the Cochrane Central Register of Controlled Trials (CENTRAL; 2018, Issue 5). Searches were also carried out in MEDLINE, Embase, CINAHL, and clinical trials databases (11 June 2018).
Selection criteria
We included randomised controlled trials in adults ≥ 18 years of age with a CVC that compared intermittent locking with heparin at any concentration versus NS. We applied no restriction on language.
Data collection and analysis
Two review authors independently selected trials, assessed quality, and extracted data. We contacted trial authors to retrieve additional information, when necessary.We carried out statistical analysis using ReviewManager 5 and assessed the overall quality of the evidence supporting assessed outcomes using GRADE. We carried out prespecified subgroup analysis.
Main results
We identified five new studies for this update (six prior studies were included in the original review), bringing the number of eligible studies to 11, with a total of 2392 participants. We noted differences in methods used by the included studies and variation in heparin concentrations (10 to 5000 IU/mL), time to follow-up (1 to 251.8 days), and the unit of analysis used (participant, catheter, line access). Combined results fromthese studies showed fewer occlusions with heparin than with NS (risk ratio (RR) 0.70, 95%confidence interval (CI) 0.51 to 0.95; P = 0.02; 1672 participants; 1025 catheters from 10 studies; I² = 14%) and provided very low-quality evidence. We carried out subgroup analysis by unit of analysis (testing for subgroup differences (P = 0.23; I² = 30.3%). When the unit of analysis was the participant, results show no clear differences in all occlusions between heparin and NS (RR 0.79, 95% CI 0.58 to 1.08; P = 0.15; 1672 participants; seven studies). Subgroup analysis using the catheter as the unit of analysis shows fewer occlusions with heparin use (RR 0.53, 95% CI 0.29 to 0.95; P = 0.03; 1025 catheters; three studies). When the unit of analysis was line access, results show no clear differences in occlusions between heparin and NS (RR 1.08, 95% CI 0.84 to 1.40; 770 line accesses; one study). We found no clear differences in the duration of catheter patency (mean difference (MD) 0.44 days, 95% CI -0.10 to 0.99; P = 0.11; 1036 participants; 752 catheters; six studies; low-quality evidence). We found no clear evidence of a difference in the following: CVC-related sepsis (RR 0.74, 95% CI 0.03 to 19.54; P = 0.86; 1097 participants; two studies; low-quality evidence); mortality (RR 0.76, 95% CI 0.44 to 1.31; P = 0.33; 1100 participants; three studies; low-quality evidence); haemorrhage at any site (RR 1.32, 95% CI 0.57 to 3.07; P = 0.52; 1245 participants; four studies; moderatequality evidence); or heparin-induced thrombocytopaenia (RR 0.21, 95% CI 0.01 to 4.27; P = 0.31; 443 participants; three studies; low-quality evidence). Themain reasons for downgrading the quality of evidencewere unclear allocation concealment, imprecision, and suspicion of publication bias.
Authors’ conclusions
Given the very low quality of the evidence, we are uncertain whether intermittent locking with heparin results in fewer occlusions than intermittent locking with NS. Low-quality evidence suggests that heparin may have little or no effect on catheter patency. Although we found no evidence of differences in safety (sepsis, mortality, or haemorrhage), the combined trials are not powered to detect rare adverse events such as heparin-induced thrombocytopaenia
Attitude control analysis of tethered de-orbiting
The increase of satellites and rocket upper stages in low earth orbit (LEO) has also increased substantially the danger of collisions in space. Studies have shown that the problem will continue to grow unless a number of debris are removed every year. A typical active debris removal (ADR) mission scenario includes launching an active spacecraft (chaser) which will rendezvous with the inactive target (debris), capture the debris and eventually deorbit both satellites. Many concepts for the capture of the debris while keeping a connection via a tether, between the target and chaser have been investigated, including harpoons, nets, grapples and robotic arms. The paper provides an analysis on the attitude control behaviour for a tethered de-orbiting mission based on the ESA e.Deorbit reference mission, where Envisat is the debris target to be captured by a chaser using a net which is connected to the chaser with a tether. The paper provides novel insight on the feasibility of tethered de-orbiting for the various mission phases such as stabilization after capture, de-orbit burn (plus stabilization), stabilization during atmospheric pass, highlighting the importance of various critical mission parameters such as the tether material. It is shown that the selection of the appropriate tether material while using simple controllers can reduce the effort needed for tethered deorbiting and can safely control the attitude of the debris/chaser connected with a tether, without the danger of a collision
Beta-delayed proton emission from <sup>21</sup>Mg
16 pags.; 9 figs.; 6 tabs.© 2015, SIF, Springer-Verlag Berlin Heidelberg. Beta-delayed proton emission from 21Mg has been measured at ISOLDE, CERN, with a detection setup consisting of two charged-particle telescopes surrounding the decay point. Altogether 27 βp branches were measured with center-of-mass energies between 0.4–7.2 MeV. Seven new βp branches were observed. Beta-delayed protons were used to determine the half-life of 21Mg as 118.6 ± 0.5 ms. From a line shape fit of the βp branches we extract the widths, spins, and parities of the resonances of 21Na. An improved interpretation of the decay scheme in accordance with the results obtained in reaction studies is presented.This work has been supported by the European Commision
within the Seventh Framework Programme “European Nuclear
Science and Applications Research”, contract no. 262010
(ENSAR), and by the Spanish research agency under number
FPA2012-32443.Peer Reviewe
Total Absorption Spectroscopy Study of Rb Decay: A Major Contributor to Reactor Antineutrino Spectrum Shape
The antineutrino spectra measured in recent experiments at reactors are
inconsistent with calculations based on the conversion of integral beta spectra
recorded at the ILL reactor. Rb makes the dominant contribution to the
reactor spectrum in the 5-8 MeV range but its decay properties are in question.
We have studied Rb decay with total absorption spectroscopy. Previously
unobserved beta feeding was seen in the 4.5-5.5 region and the GS to GS feeding
was found to be 87.5(25)%. The impact on the reactor antineutrino spectra
calculated with the summation method is shown and discussed.Comment: 6 pages, 3 figure
Characterization of a novel proton-CT scanner based on Silicon and LaBr(Ce) detectors
Treatment planning systems at proton-therapy centres generally use X-ray
computed tomography (CT) as primary imaging technique to infer the proton
treatment doses to tumour and healthy tissues. However, proton stopping powers
in the body, as derived from X-ray images, suffer from important proton-range
uncertainties. In order to reduce this uncertainty in range, one could use
proton-CT images instead. The main goal of this work is to test the
capabilities of a newly-developed proton-CT scanner, based on the use of a set
of tracking detectors and a high energy resolution scintillator for the
residual energy of the protons. Different custom-made phantoms were positioned
at the field of view of the scanner and were irradiated with protons at the CCB
proton-therapy center in Krakow. We measured with the phantoms at different
angles and produced sinograms that were used to obtain reconstructed images by
Filtered Back-Projection (FBP). The obtained images were used to determine the
capabilities of our scanner in terms of spatial resolution and proton Relative
Stopping Power mapping and validate its use as proton-CT scanner. The results
show that the scanner can produce medium-high quality images, with spatial
resolution better than 2 mm in radiography, below 3 mm in tomography and
resolving power in the RSP comparable to other state of the art pCT cameras
MicroRNA signature from extracellular vesicles of HCV/HIV co-infected individuals differs from HCV mono-infected
Hepatitis C virus (HCV) coinfection with human immunodeficiency virus (HIV) has a detrimental impact on disease progression. Increasing evidence points to extracellular vesicles (EVs) as important players of the host-viral cross-talk. The microRNAs (miRNAs), as essential components of EVs cargo, are key regulators of normal cellular processes and also promote viral replication, viral pathogenesis, and disease progression. We aimed to characterize the plasma-derived EVs miRNA signature of chronic HCV infected and HIV coinfected patients to unravel the molecular mechanisms of coinfection. EVs were purified and characterized from 50 plasma samples (21 HCV mono- and 29 HCV/HIV co-infected). EV-derived small RNAs were isolated and analyzed by massive sequencing. Known and de novo miRNAs were identified with miRDeep2. Significant differentially expressed (SDE) miRNA identification was performed with generalized linear models and their putative dysregulated biological pathways were evaluated. Study groups were similar for most clinical and epidemiological characteristics. No differences were observed in EVs size or concentration between groups. Therefore, HCV/HIV co-infection condition did not affect the concentration or size of EVs but produced a disturbance in plasma-derived EVs miRNA cargo. Thus, a total of 149 miRNAs were identified (143 known and 6 de novo) leading to 37 SDE miRNAs of which 15 were upregulated and 22 downregulated in HCV/HIV co-infected patients. SDE miRNAs regulate genes involved in inflammation, fibrosis, and cancer, modulating different biological pathways related to HCV and HIV pathogenesis. These findings may help to develop new generation biomarkers and treatment strategies, in addition to elucidate the mechanisms underlying virus-host interaction. KEY MESSAGES: HCV and HCV/HIV displayed similar plasma-EV size and concentration. EVs- derived miRNA profile was characterized by NGS. 37 SDE miRNAs between HCV and HCV/HIV were observed. SDE miRNAs regulate genes involved in inflammation, fibrosis and cancer.Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been supported by grants from (1) Institute of Health Carlos III, Spain [PI18CIII/00020/ to AFR], (2) PID2021–126781OB-I00 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”, (3) The SPANISH AIDS Research Network RD16CIII/0002/0002 - ISCIII – FEDER, (4) Centro de Investigación en Red en Enfermedades Infecciosas (CIBERINFEC) CB21/13/00044, (5) the National Agency for Scientific and Technology Promotion (ANPCyT) (PICT 2017 Nº713), and (6) the National Research Council (CONICET, PIP 2021-2023). V.C. received funding form the Asociación Universitaria Iberoamericana de Postgrado (AUIP) for the Academic Mobility Scholarship Program. P.V., E.D.M., and M.V.P. are members of the CONICET-Research Career Program. V.C. is a fellow from ANPCyT. The funder’s had no role in the study design, data collection and analysis, decision to publish, or the preparation of the manuscript.S
Proton radiographs using position-sensitive silicon detectors and high-resolution scintillators
Proton therapy is a cancer treatment technique currently in growth worldwide.
It offers advantages with respect to conventional X-ray and -ray
radiotherapy, in particular, a better control of the dose deposition allowing
to reach a higher conformity in the treatments. Therefore, it causes less
damage to the surrounding healthy tissue and less secondary effects. However,
in order to take full advantage of its potential, improvements in treatment
planning and dose verification are required. A new prototype of proton Computed
Tomography scanner is proposed to design more accurate and precise treatment
plans for proton therapy. Here, results obtained from an experiment performed
using a 100-MeV proton beam at the CCB facility in Krakow (Poland) are
presented. Proton radiographs of PMMA samples of 50-mm thickness with spatial
patterns in aluminum were taken. Their properties were studied, including
reproduction of the dimensions, spatial resolution and sensitivity to different
materials. They demonstrate the capabilities of the system to produce images
with protons. Structures of up to 2 mm are nicely resolved and the sensitivity
of the system was enough to distinguish thicknesses of 10 mm of aluminum or
PMMA. This constitutes a first step to validate the device as a proton
radiography scanner previous to the future tests as a proton CT scanner.Comment: 7 pages, 11 figures, submitted to IEEE TNS ANIMMA 2021 Conference
Proceeding
Effect of resource spatial correlation and Hunter-Fisher-Gatherer mobility on social cooperation in Tierra del Fuego
This article presents an agent-based model designed to explore the development of cooperation
in hunter-fisher-gatherer societies that face a dilemma of sharing an unpredictable resource
that is randomly distributed in space. The model is a stylised abstraction of the
Yamana society, which inhabited the channels and islands of the southernmost part of
Tierra del Fuego (Argentina-Chile). According to ethnographic sources, the Yamana developed
cooperative behaviour supported by an indirect reciprocity mechanism: whenever
someone found an extraordinary confluence of resources, such as a beached whale, they
would use smoke signals to announce their find, bringing people together to share food and
exchange different types of social capital. The model provides insight on how the spatial
concentration of beachings and agents’ movements in the space can influence cooperation.
We conclude that the emergence of informal and dynamic communities that operate as a
vigilance network preserves cooperation and makes defection very costly.MICINN http://www.idi.mineco.gob.es/ CSD2010-00034 (SimulPast CONSOLIDER-INGENIO 2010) and HAR2009-06996; the government of Castilla y Leónhttp://www.jcyl.es/ GREX251-2009; the Argentine CONICET http://www.conicet.gov.ar/PIP-0706; and the Wenner-Gren Foundation for Anthropological Researchhttp://www.wennergren.org/ "Social Aggregation: A Yamana Society's Short Term Episode to Analyse Social Interaction, Tierra del Fuego, Argentina". The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscrip
- …