123 research outputs found

    Painful constipation: a neglected entity?

    Get PDF
    Functional chronic constipation is a common symptom in daily clinical practice. Although the definition of constipation may be variable, there is usually agreement that (at least for research purposes) the definition given by the Rome Committee are useful. However, some blind spots or hidden angles remain, even in the more thorough classifications; among these, there is painful constipation, a poorly defined yet clinically encountered entity. The present article reviews the current knowledge about painful constipation, trying to put together the scarce data available, and to frame it in the more general context of chronic constipation

    Clinical Significance of Cartilage Biomarkers for Monitoring Structural Joint Damage in Rheumatoid Arthritis Patients Treated with Anti-TNF Therapy

    Get PDF
    PURPOSE: With the current use of biologics in rheumatoid arthritis (RA), there is a need to monitor ongoing structural joint damage due to the dissociation of articular cartilage damage from disease activity of RA. This study longitudinally analyzed levels of serum cartilage biomarkers during 54 weeks of infliximab therapy, to evaluate the feasibility of biomarkers for monitoring structural joint damage. METHODS: Subjects comprised 33 patients with early RA and 33 patients with established RA. All patients received 3 mg/kg of infliximab and methotrexate for 54 weeks. Levels of the following serum cartilage markers were measured at baseline and at weeks 14, 22, and 54: hyaluronan (HA); cartilage oligometric matrix protein (COMP); type II collagen (CII)-related neoepitope (C2C); type II procollagen carboxy-propeptide (CPII); and keratin sulfate (KS). Time courses for each biomarker were assessed, and relationships between these biomarkers and clinical or radiographic parameters generally used for RA were investigated. RESULTS: Levels of CRP, MMP-3, DAS28-CRP, and annual progression of TSS were improved to similar degrees in both groups at week 54. HA and C2C/CPII were significantly decreased compared to baseline in the early RA group (p<0.001), whereas HA and COMP, but not C2C/CPII, were decreased in the established RA group. Strikingly, serum C2C/CPII levels were universally improved in early RA, regardless of EULAR response grade. Both ΔHA and ΔC2C/CPII from baseline to week 54 correlated significantly with not only ΔCRP, but also ΔDAS28 in early RA. Interestingly, when partial correlation coefficients were calculated by standardizing CRP levels, the significant correlation of ΔHA to ΔDAS28 disappeared, whereas correlations of ΔC2C/CPII to ΔDAS28, ΔJNS, and ΔHAQ remained significant. These results suggest a role of ΔC2C/CPII as a marker of ongoing structural joint damage with the least association with CRP, and that irreversible cartilage damage in established RA limits restoration of the C2C/CPII level, even with tight control of joint inflammation. CONCLUSION: The temporal course of C2C/CPII level during anti-TNF therapy indicates that CII turnover shifts toward CII synthesis in early RA, but not in established RA, potentially due to irreversible cartilage damage. ΔC2C/CPII appears to offer a useful marker reflecting ongoing structural joint damage, dissociated from inflammatory indices such as CRP and MMP-3

    Toward an international consensus-Integrating lipoprotein apheresis and new lipid-lowering drugs

    Get PDF
    Background: Despite advances in pharmacotherapy of lipid disorders, many dyslipidemic patients do not attain sufficient lipid lowering to mitigate risk of atherosclerotic cardiovascular disease. Several classes of novel lipid-lowering agents are being evaluated to reduce atherosclerotic cardiovascular disease risk. Lipoprotein apheresis (LA) is effective in acutely lowering the plasma concentrations of atherogenic lipoproteins including low-density lipoprotein cholesterol and lipoprotein(a), and novel lipid-lowering drugs may dampen the lipid rebound effect of LA, with the possibility that LA frequency may be decreased, in some cases even be discontinued. Sources of material: This document builds on current American Society for Apheresis guidelines and, for the first time, makes recommendations from summarized data of the emerging lipid-lowering drug classes (inhibitors of proprotein convertase subtilisin/kexin type 9 or microsomal triglyceride transfer protein, high-density lipoprotein mimetic), including the available evidence on combination therapy with LA with respect to the management of patients with dyslipidemia. Abstract of findings: Recommendations for different indications are given based on the latest evidence. However, except for lomitapide in homozygous familial hypercholesterolemia and alirocumab/evolocumab in heterozygous familial hypercholesterolemia subjects, limited data are available on the effectiveness and safety of combination therapy. More studies on combining LA with novel lipid-lowering drugs are needed. Conclusion: Novel lipid-lowering agents have potential to improve the performance of LA, but more evidence is needed. The Multidisciplinary International Group for Hemapheresis TherapY and Metabolic DIsturbances Contrast scientific society aims to establish an international registry of clinical experience on LA combination therapy to expand the evidence on this treatment in individuals at high cardiovascular disease risk

    Progress in Diamond Detector Development

    Get PDF
    Detectors based on Chemical Vapor Deposition (CVD) diamond have been used successfully in Luminosity and Beam Condition Monitors (BCM) in the highest radiation areas of the LHC. Future experiments at CERN will accumulate an order of magnitude larger fluence. As a result, an enormous effort is underway to identify detector materials that can operate under fluences of 1 · 1016 n cm−2 and 1 · 1017 n cm−2. Diamond is one candidate due to its large displacement energy that enhances its radiation tolerance. Over the last 30 years the RD42 collaboration has constructed diamond detectors in CVD diamond with a planar geometry and with a 3D geometry to extend the material's radiation tolerance. The 3D cells in these detectors have a size of 50 µm×50 µm with columns of 2.6 µm in diameter and 100 µm×150 µm with columns of 4.6 µm in diameter. Here we present the latest beam test results from planar and 3D diamond pixel detectors

    A study of the radiation tolerance of cvd diamond to 70 mev protons, fast neutrons and 200 mev pions

    Get PDF
    We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015^{15} protons/cm2^{2}, (1.43±0.14) × 1016^{16} neutrons/cm2^{2}, and (6.5±1.4) × 1014 pions/cm2^{2}, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2^{2}/(pμm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2^{2}/(nμm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2^{2}/(πμm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve

    Beam test results of 3D pixel detectors constructed with poly-crystalline CVD diamond

    Get PDF
    As a possible candidate for extremely radiation tolerant tracking devices we present a novel detector design - namely 3D detectors - based on poly-crystalline CVD diamond sensors with a pixel readout. The fabrication of recent 3D detectors as well their results in recent beam tests are presented. We measured the hit efficiency and signal response of two 3D diamond detectors with 50 × 50 μm cell sizes using pixel readout chip technologies currently used at CMS and ATLAS. In all runs, both devices attained efficiencies >98 % in a normal incident test beam of minimum ionising particles. The highest efficiency observed during the beam tests was 99.2 %

    Right drug, right patient, right time: aspiration or future promise for biologics in rheumatoid arthritis?

    Get PDF
    Individualising biologic disease-modifying anti-rheumatic drugs (bDMARDs) to maximise outcomes and deliver safe and cost-effective care is a key goal in the management of rheumatoid arthritis (RA). Investigation to identify predictive tools of bDMARD response is a highly active and prolific area of research. In addition to clinical phenotyping, cellular and molecular characterisation of synovial tissue and blood in patients with RA, using different technologies, can facilitate predictive testing. This narrative review will summarise the literature for the available bDMARD classes and focus on where progress has been made. We will also look ahead and consider the increasing use of ‘omics’ technologies, the potential they hold as well as the challenges, and what is needed in the future to fully realise our ambition of personalised bDMARD treatment

    Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

    Get PDF
    A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe

    Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

    Get PDF
    The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment's silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to Phi(eq) = 2x10(16) cm(-2), and an ionising dose of approximate to 5 MGy after an integrated luminosity of 3000 fb(-1). Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 mu m thick p-bulk pad diodes and strip sensors irradiated up to fluences of Phi(eq) = 1.3 x 10(16) cm(-2) are shown.Peer reviewe

    Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

    Get PDF
    The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5–7.5×1034^{34} cm2^{-2}s1^{-1}. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000–4000 fb-1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV. To cope with these challenging environmental conditions, the strip tracker of the CMS experiment will be upgraded using modules with two closely-spaced silicon sensors to provide information to include tracking in the Level-1 trigger selection. This paper describes the performance, in a test beam experiment, of the first prototype module based on the final version of the CMS Binary Chip front-end ASIC before and after the module was irradiated with neutrons. Results demonstrate that the prototype module satisfies the requirements, providing efficient tracking information, after being irradiated with a total fluence comparable to the one expected through the lifetime of the experiment
    corecore