361 research outputs found
Enhanced Stray-Load Loss Measurements Through a Zig-Zag Variable Load Test Approach
This article proposes an enhanced procedure for executing the standard variable load test that allows obtaining high correlation factors for indirectly measured stray-load loss during efïŹciency tests of induction motors. This helps to achieve the minimum values required by the international standards to consider the variable load test well executed, avoiding unwelcome test repetitions and leading to signiïŹcant amount of time saved. With the machine at steady-state temperature, the enhanced procedure consistsofalternativelyapplyingloadlevelshigherandlowerthan the rated load, so that the stator winding temperature zigzags aroundtheratedvalue.Hence,multiplereadingscanbeperformed for each load point, having the machine in isothermal conditions. This allows averaging many measurements of the same load point to mitigate the impact of instrumentation and reading errors. The article includes load tests conducted on different induction motor sizesandpolecounts,applyingboththestandardvariableloadtest procedure and the proposed approach. The experimental results show that theproposed technique allows achieving higher correlation factors on the stray-load losses than the standard procedure
Dietary fat intake as a risk factor for the development of diabetes. Multinational, multicenter study of the Mediterranean Group for the Study of Diabetes (MGDS)
In the context of the Multinational MGSD Nutrition Study, three groups of subjects were studied: 204 subjects with recently diagnosed diabetes(RDM),42subjectswithundiagnoseddiabetes(UDM)(AmericanDiabetesAssociation criteriaâfasting plasma glucose [FPG] 126 mg/dl), and 55 subjects with impaired fasting glucose(IFG)(FPG 110and126mg/dl).Eachgroupwascomparedwithacontrolgroupof nondiabetic subjects, matched one by one for center, sex, age, and BMI. Nutritional habits were evaluated by a dietary history method, validated against the 3-day diet diary. In RDM, the questionnaire referred to the nutritional habits before the diagnosis of diabetes. Demographic data were collected, and anthropometrical and biochemical measurements were taken. RESULTSâ Compared with control subjects, RDM more frequently had a family history of diabetes(49.0vs.14.2%;P0.001),exercisedless(exerciseindex53.5vs.64.4;P0.01),and more frequently had sedentary professions (47.5 vs. 27.4%; P 0.001). Carbohydrates contributed less to their energy intake (53.5 vs. 55.1%; P 0.05), whereas total fat (30.2 0.5 vs. 27.8 0.5%; P 0.001) and animal fat (12.2 0.3 vs. 10.8 0.3%; P 0.01) contributed moreandtheplant-to-animalfatratiowaslower(1.50.1vs.1.80.1;P0.01).UDMmore frequentlyhadafamilyhistoryofdiabetes(38.1vs.19.0%;P0.05)andsedentaryprofessions (58.5vs.34.1%;P0.05),carbohydratescontributedlesstotheirenergyintake(47.61.7vs. 52.81.4%;P0.05),totalfat(34.71.5vs.30.41.2%;P0.05)andanimalfat(14.2 0.9 vs. 10.6 0.7%; P 0.05) contributed more, and the plant-to-animal fat ratio was lower (1.6 0.2 vs. 2.3 0.4; P 0.05). IFG differed only in the prevalence of family history of diabetes (32.7 vs. 16.4%; P 0.05). CONCLUSIONSâ Our data support the view that increased animal fat intake is associated with the presence of diabetes
High-dose-rate brachytherapy for high-grade vaginal intraepithelial neoplasia: A dosimetric analysis
Pre-implant magnetic resonance and transrectal ultrasound imaging in high-dose-rate prostate brachytherapy : comparison of prostate volumes, craniocaudal extents, and contours
Purpose: The purpose of this study was to compare the prostate contours drawn by two radiation oncologists and one radiologist on magnetic resonance (MR) and transrectal ultrasound (TRUS) images. TRUS intra- and inter-fraction variability as well as TRUS vs. MR inter-modality and inter-operator variability were studied. Material and methods: Thirty patients affected by localized prostate cancer and treated with interstitial high-dose-rate (HDR) prostate brachytherapy at the National Cancer Institute in Milan were included in this study. Twenty-five patients received an exclusive two-fraction (14 Gy/fraction) treatment, while the other 5 received a single 14 Gy fraction as a boost after external beam radiotherapy. The prostate was contoured on TRUS images acquired before (virtual US) and after (real US) needle implant by two radiation oncologists, whereas on MR prostate was independently contoured by the same radiation oncologists (MR1, MR2) and by a dedicated radiologist (MR3). Absolute differences of prostate volumes ( 06V) and craniocaudal extents ( 06dz) were evaluated. The Dice's coefficient (DC) was calculated to quantify spatial overlap between MR contours. Results: Significant difference was found between Vvirtual and Vlive (p < 0.001) for the first treatment fractions and between VMR1 and VMR2 (p = 0.043). Significant difference between cranio-caudal extents was found between dzvirtual and dzlive (p < 0.033) for the first treatment fractions, between dzvirtual of the first treatment fractions and dzMR1 (p < 0.001) and between dzMR1 and dzMR3 (p < 0.01). Oedema might be responsible for some of the changes in US volumes. Average DC values resulting from the comparison MR1 vs. MR2, MR1 vs. MR3 and MR2 vs. MR3 were 0.95 \ub1 0.04 (range, 0.82-0.99), 0.87 \ub1 0.04 (range, 0.73-0.91) and 0.87 \ub1 0.04 (range, 0.72-0.91), respectively. Conclusions: Our results demonstrate the importance of a multiprofessional approach to TRUS-guided HDR prostate brachytherapy. Specific training in MR and US prostate imaging is recommended for centers that are unfamiliar with HDR prostate brachytherapy
Axion searches with the EDELWEISS-II experiment
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons GeV in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, , similar to the more
indirect solar neutrino bound. Finally we place a limit on , where is the
effective axion-nucleon coupling for Fe. Combining these results we
fully exclude the mass range keV for DFSZ axions and
keV for KSVZ axions
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
Validation of techniques to mitigate copper surface contamination in CUORE
In this article we describe the background challenges for the CUORE
experiment posed by surface contamination of inert detector materials such as
copper, and present three techniques explored to mitigate these backgrounds.
Using data from a dedicated test apparatus constructed to validate and compare
these techniques we demonstrate that copper surface contamination levels better
than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels
are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit
on the number of background counts in the region of interest is 0.02-0.03
counts/keV/kg/y depending on the adopted mitigation technique.Comment: 10 pages, 6 figures, 6 table
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
- âŠ