966 research outputs found

    Hearing: Travelling Wave or Resonance?

    Get PDF
    A fresh look at classic work of Thomas Gold on how the inner ear processes soun

    The Active Traveling Wave in the Cochlea

    Get PDF
    A sound stimulus entering the inner ear excites a deformation of the basilar membrane which travels along the cochlea towards the apex. It is well established that this wave-like disturbance is amplified by an active system. Recently, it has been proposed that the active system consists of a set of self-tuned critical oscillators which automatically operate at an oscillatory instability. Here, we show how the concepts of a traveling wave and of self-tuned critical oscillators can be combined to describe the nonlinear wave in the cochlea.Comment: 5 pages, 2 figure

    Mind the gap: the effects of temporal and spatial separation in localization of dual touches on the hand

    Get PDF
    In this study, we aimed to relate the findings from two predominantly separate streams of literature, one reporting on the localisation of single touches on the skin, and the other on the distance perception of dual touches. Participants were touched with two points, delivered either simultaneously or separated by a short delay to various locations on their left hand dorsum. They then indicated on a size-matched hand silhouette the perceived locations of tactile stimuli. We quantified the deviations between the actual stimulus grid and the corresponding perceptual map which was constructed from the perceived tactile locations, and we calculated the precision of tactile localisation (i.e. the variability across localisation attempts). The evidence showed that the dual touches, akin to single touch stimulations, were mislocalised distally and that their variable localisation error was reduced near joints, particularly near knuckles. However, contrary to single-touch localisation literature, we observed for the dual touches to be mislocalised towards the ulnar side of the hand, particularly when they were presented sequentially. Further, the touches presented in a sequential order were slightly ‘repelled’ from each other and their perceived distance increased, while the simultaneous tactile pairs were localised closer to each other and their distance was compressed. Whereas the sequential touches may have been localised with reference to the body, the compression of tactile perceptual space for simultaneous touches was related in the previous literature to signal summation and inhibition and the low-level factors, including the innervation density and properties of receptive fields of somatosensory neurons

    A Comprehensive Three-Dimensional Model of the Cochlea

    Get PDF
    The human cochlea is a remarkable device, able to discern extremely small amplitude sound pressure waves, and discriminate between very close frequencies. Simulation of the cochlea is computationally challenging due to its complex geometry, intricate construction and small physical size. We have developed, and are continuing to refine, a detailed three-dimensional computational model based on an accurate cochlear geometry obtained from physical measurements. In the model, the immersed boundary method is used to calculate the fluid-structure interactions produced in response to incoming sound waves. The model includes a detailed and realistic description of the various elastic structures present. In this paper, we describe the computational model and its performance on the latest generation of shared memory servers from Hewlett Packard. Using compiler generated threads and OpenMP directives, we have achieved a high degree of parallelism in the executable, which has made possible several large scale numerical simulation experiments that study the interesting features of the cochlear system. We show several results from these simulations, reproducing some of the basic known characteristics of cochlear mechanics.Comment: 22 pages, 5 figure

    Optics-less smart sensors and a possible mechanism of cutaneous vision in nature

    Full text link
    Optics-less cutaneous (skin) vision is not rare among living organisms, though its mechanisms and capabilities have not been thoroughly investigated. This paper demonstrates, using methods from statistical parameter estimation theory and numerical simulations, that an array of bare sensors with a natural cosine-law angular sensitivity arranged on a flat or curved surface has the ability to perform imaging tasks without any optics at all. The working principle of this type of optics-less sensor and the model developed here for determining sensor performance may be used to shed light upon possible mechanisms and capabilities of cutaneous vision in nature

    Non-invasive biophysical measurement of travelling waves in the insect inner ear

    Get PDF
    Frequency analysis in the mammalian cochlea depends on the propagation of frequency information in the form of a travelling wave (TW) across tonotopically arranged auditory sensilla. TWs have been directly observed in the basilar papilla of birds and the ears of bush-crickets (Insecta: Orthoptera) and have also been indirectly inferred in the hearing organs of some reptiles and frogs. Existing experimental approaches to measure TW function in tetrapods and bushcrickets are inherently invasive, compromising the fine-scale mechanics of each system. Located in the forelegs, the bushcricket ear exhibits outer, middle and inner components; the inner ear containing tonotopically arranged auditory sensilla within a fluid-filled cavity, and externally protected by the leg cuticle. Here, we report bush-crickets with transparent ear cuticles as potential model species for direct, non-invasive measuring of TWs and tonotopy. Using laser Doppler vibrometry and spectroscopy, we show that increased transmittance of light through the ear cuticle allows for effective non-invasive measurements of TWs and frequency mapping. More transparent cuticles allow several properties of TWs to be precisely recovered and measured in vivo from intact specimens. Our approach provides an innovative, noninvasive alternative to measure the natural motion of the sensillia-bearing surface embedded in the intact inner ear fluid
    corecore