17 research outputs found

    Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study

    Get PDF
    BACKGROUND: This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. METHODS: The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. RESULTS: In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p < 0.001). The trend for better outcomes for the novel technique in terms of stiffness and yield load did not reach statistical significance (p > 0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. CONCLUSIONS: The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone

    Minimally invasive reconstruction of lateral tibial plateau fractures using the jail technique: a biomechanical study

    Full text link
    Background: This study described a novel, minimally invasive reconstruction technique of lateral tibial plateau fractures using a three-screw jail technique and compared it to a conventional two-screw osteosynthesis technique. The benefit of an additional screw implanted in the proximal tibia from the anterior at an angle of 90° below the conventional two-screw reconstruction after lateral tibial plateau fracture was evaluated. This new method was called the jail technique. Methods: The two reconstruction techniques were tested using a porcine model (n = 40). Fracture was simulated using a defined osteotomy of the lateral tibial plateau. Load-to-failure and multiple cyclic loading tests were conducted using a material testing machine. Twenty tibias were used for each reconstruction technique, ten of which were loaded in a load-to-failure protocol and ten cyclically loaded (5000 times) between 200 and 1000 N using a ramp protocol. Displacement, stiffness and yield load were determined from the resulting load displacement curve. Failure was macroscopically documented. Results: In the load-to-failure testing, the jail technique showed a significantly higher mean maximum load (2275.9 N) in comparison to the conventional reconstruction (1796.5 N, p  0.05). In cyclic testing, the jail technique also showed better trends in displacement that were not statistically significant. Failure modes showed a tendency of screws cutting through the bone (cut-out) in the conventional reconstruction. No cut-out but a bending of the lag screws at the site of the additional third screw was observed in the jail technique. Conclusions: The results of this study indicate that the jail and the conventional technique have seemingly similar biomechanical properties. This suggests that the jail technique may be a feasible alternative to conventional screw osteosynthesis in the minimally invasive reconstruction of lateral tibial plateau fractures. A potential advantage of the jail technique is the prevention of screw cut-outs through the cancellous bone.<br

    Abstracts from the Food Allergy and Anaphylaxis Meeting 2016

    Get PDF

    Shoulder injuries in polytraumatized patients: an analysis of the TraumaRegister DGUÂź

    No full text
    Background!#!The aim of the present study was to analyze the prevalence, epidemiology and relevance of shoulder injuries in polytraumatized patients in a large national trauma database. We hypothesize a high prevalence of shoulder injuries in traffic accidents and a high prevalence of concomitant injuries of the thorax leading to an aggravated clinical course and higher Injury Severity Score (ISS). Furthermore, we hypothesize an increased rate of surgical treatment with the severity of the injury.!##!Materials and methods!#!The retrospective analysis is based on the database (2002-2013) of the TraumaRegister DGUÂź and includes statistical data from 608 hospitals. The severity of injuries and trauma were scaled using the Abbreviated Injury Scale (AIS), and the Injury Severity Score (ISS), respectively. Patients with an ISS ≄ 16 were included in the study, and injuries were subdivided according to their anatomical involvement and analyzed with respect to the trauma mechanism and the resulting injuries.!##!Results!#!In this study, 54,076 cases of patients with an ISS ≄ 16 were analyzed. Shoulder injuries occurred in 15,115 patients (27.9%). Of these, 68.5% were caused by traffic accidents, especially in motorbike, bicycle, and pedestrian accidents. We found more shoulder injuries in blunt trauma mechanisms. Moreover, patients with shoulder injuries spent on average 1.7 more days on the intensive care unit (ICU), or intermediate care unit (IMCU), according to the severity of the injury, and had longer overall hospital stays (26.2 vs. 24.1 days) than patients without shoulder injuries. The overall ISS was increased in patients with shoulder injuries, whereas an increase of mortality could not be identified. Concomitant thoracic injuries occurred significantly more often in patients with shoulder injuries (82.9% vs. 69.6%). Injuries of the abdomen, pelvis, and lower extremity showed no correlation with shoulder injuries, whereas head and spine injuries showed a significant correlation.!##!Conclusion!#!Shoulder injuries are very common in polytraumatized patients. Together with their distinctive concomitant injuries, they have an aggravating impact on the clinical progress. Our data confirm the correlation with thoracic injuries. Furthermore, we identified an increased risk of shoulder injuries in motorbike, bicycle, and pedestrian accidents. An increase in mortality could not be identified

    Outcomes After Transcatheter Mitral Valve Replacement According to Regurgitation Etiology.

    No full text
    BACKGROUND Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unelucidated yet. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency Registry (CHOICE-MI) registry. METHODS Out of 746 patients, 229 (30.7%) patients underwent TMVR. The study population was subdivided according to primary, secondary or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalisation for heart failure at 1 year. Secondary study endpoints included all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class and residual MR, both at discharge and 1 year. RESULTS The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%), and mixed MR (12.9%). Technical success was similar according to MR etiology as was procedural mortality. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P=0.1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2% and 32.1% of the patients with primary, secondary and mixed MR (P=0.07), respectively. CONCLUSIONS In our study, we did not find differences in short- and 1-year outcomes after TMVR according to MR etiology
    corecore