461 research outputs found

    A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries

    Get PDF
    The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30m walking trial. The precision in comparison with the reference system was 4.4°, 2.7° and 4.2° for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8°, 0.7° and 1.8°. The averaged ROM of the five patients' healthy knee were 70.1° [standard deviation (SD) 5.8°], 24.0° (SD 3.0°) and 12.0° (SD 6.3°) for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5° (SD 4.1°), 21.7° (SD 4.9°) and 10.2° (SD 4.6°) 1year following the reconstruction. The results for the pathologic knee were 64.5° (SD 6.9°), 20.6° (SD 4.0°) and 19.7° (8.2°) during the first evaluation, and 72.3° (SD 2.4°), 25.8° (SD 6.4°) and 12.4° (SD 2.3°) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surger

    Quantifying dimensions of physical behavior in chronic pain conditions.

    Get PDF
    BACKGROUND: Chronic pain, defined as persistent or recurrent pain lasting longer than 3 months, is a frequent condition affecting an important percent of population worldwide. Pain chronicity can be caused by many different factors and is a frequent component of many neurological disorders. An important aspect for clinical assessment and design of effective treatment and/or rehabilitation strategies is to better understand the impact of pain on domains of functioning in everyday life. The aim of this study was to identify the objectively quantifiable features of physical functioning in daily life and to evaluate their effectiveness to differentiate behavior among subjects with different pain conditions. METHOD: Body worn sensors were used to record movement data during five consecutive days in 92 subjects. Sensor data were processed to characterize the physical behavior in terms of type, intensity, duration and temporal pattern of activities, postures and movements performed by subjects in daily life. Metrics quantifying these features were subsequently used to devise composite scores using a factor analysis approach. The severity of clinical condition was assessed using a rating of usual pain intensity on a 10-cm visual analog scale. The relationship between pain intensity and the estimated metrics/composite scores was assessed using multiple regression and discriminant analysis. RESULTS: According to the factor analysis solution, two composite scores were identified, one integrating the metrics quantifying the amount and duration of activity periods, and the other the metrics quantifying complexity of temporal patterns, i.e., the diversity of body movements and activities, and the manner in which they are organized throughout time. All estimated metrics and composite scores were significantly different between groups of subjects with clinically different pain levels. Moreover, analysis revealed that pain intensity seemed to have a more significant impact on the overall physical behavior, as it was quantified by a global composite score, whereas the type of chronic pain appeared to influence mostly the complexity of the temporal pattern. CONCLUSION: The methodology described could be informative for the design of objective outcome measures in chronic pain management/rehabilitation programs

    The relationship between video display terminals (VDTs) usage and dermatologic manifestations : a cross sectional study

    Get PDF
    BACKGROUND: Recently, it has been observed that Video Display Terminals (VDTs) usage for long periods can cause some dermatological manifestations on the face. An analytical cross-sectional study was designed in order to determine this relationship. METHODS: In this study, 600 office workers were chosen randomly from an organization in Tehran (Iran). The subjects were then divided into two groups based on their exposure to VDTs. 306 workers were considered exposure negative (non VDT user) who worked less than 7 hours a week with VDTs. The remainders 294 were exposure-positive, who worked 7 hours or more with VDTs. The frequency of dermatologic manifestations was compared in these two groups. RESULTS: In the exposure-positive and exposure-negative groups, the frequency of these dermatologic manifestations were 27 and 5 respectively. After statistical analysis, a P.value of < 0.05 was obtained indicating a statistically significant difference between these two groups for dermatological manifestations. CONCLUSION: According to our study, there is a relationship between dermatologic manifestations on the face and exposure to VDTs

    Robustness of In-Laboratory and Daily-Life Gait Speed Measures over One Year in High Functioning 61- To 70-Year-Old Adults

    Get PDF
    Introduction: Gait speed is a simple and safe measure with strong predictive value for negative health outcomes in clinical practice, yet in-laboratory gait speed seems not representative for daily-life gait speed. This study aimed to investigate the interrelation between and robustness of in-laboratory and daily-life gait speed measures over 12 months in 61- to 70-year-old adults. Methods: Gait speed was assessed in laboratory through standardized stopwatch tests and in daily life by 7 days of trunk accelerometry in the PreventIT cohort, at baseline, and after 6 and 12 months. The interrelation was investigated using Pearson's correlations between gait speed measures at each time point. For robustness, changes over time and variance components were assessed by ANOVA and measurement agreement over time by Bland-Altman analyses. Results: Included were 189 participants (median age 67 years [interquartile range: 64-68], 52.2% females). In-laboratory and daily-life gait speed measures showed low correlations (Pearson's r = 0.045-0.455) at each time point. Moreover, both in-laboratory and daily-life gait speed measures appeared robust over time, with comparable and smaller within-subject than between-subject variance (range 0.001-0.095 m/s and 0.032-0.397 m/s, respectively) and minimal differences between measurements over time (Bland-Altman) with wide limits of agreement (standard deviation of mean difference range: 0.12-0.34 m/s). Discussion/Conclusion: In-laboratory and daily-life gait speed measures show robust assessments of gait speed over 12 months and are distinct constructs in this population of high-functioning adults. This suggests that (a combination of) both measures may have added value in predicting health outcomes

    Technology Innovation Enabling Falls Risk Assessment in a Community Setting

    Get PDF
    Approximately one in three people over the age of 65 will fall each year, resulting in significant financial, physical, and emotional cost on the individual, their family, and society. Currently, falls are managed using on-body sensors and alarm pendants to notify others when a falls event occurs. However these technologies do not prevent a fall from occurring. There is now a growing focus on falls risk assessment and preventative interventions. Falls risk is currently assessed in a clinical setting by expert physiotherapists, geriatricians, or occupational therapists following the occurrence of an injurious fall. As the population ages, this reactive model of care will become increasingly unsatisfactory, and a proactive community-based prevention strategy will be required. Recent advances in technology can support this new model of care by enabling community-based practitioners to perform tests that previously required expensive technology or expert interpretation. Gait and balance impairment is one of the most common risk factors for falls. This paper reviews the current technical and non-technical gait and balance assessments, discusses how low-cost technology can be applied to objectively administer and interpret these tests in the community, and reports on recent research where body-worn sensors have been utilized. It also discusses the barriers to adoption in the community and proposes ethnographic research as a method to investigate solutions to these barriers

    Cognitive loading affects motor awareness and movement kinematics but not locomotor trajectories during goal-directed walking in a virtual reality environment.

    Get PDF
    The primary purpose of this study was to investigate the effects of cognitive loading on movement kinematics and trajectory formation during goal-directed walking in a virtual reality (VR) environment. The secondary objective was to measure how participants corrected their trajectories for perturbed feedback and how participants' awareness of such perturbations changed under cognitive loading. We asked 14 healthy young adults to walk towards four different target locations in a VR environment while their movements were tracked and played back in real-time on a large projection screen. In 75% of all trials we introduced angular deviations of ±5° to ±30° between the veridical walking trajectory and the visual feedback. Participants performed a second experimental block under cognitive load (serial-7 subtraction, counter-balanced across participants). We measured walking kinematics (joint-angles, velocity profiles) and motor performance (end-point-compensation, trajectory-deviations). Motor awareness was determined by asking participants to rate the veracity of the feedback after every trial. In-line with previous findings in natural settings, participants displayed stereotypical walking trajectories in a VR environment. Our results extend these findings as they demonstrate that taxing cognitive resources did not affect trajectory formation and deviations although it interfered with the participants' movement kinematics, in particular walking velocity. Additionally, we report that motor awareness was selectively impaired by the secondary task in trials with high perceptual uncertainty. Compared with data on eye and arm movements our findings lend support to the hypothesis that the central nervous system (CNS) uses common mechanisms to govern goal-directed movements, including locomotion. We discuss our results with respect to the use of VR methods in gait control and rehabilitation

    Centre of pressure characteristics in normal, planus and cavus feet

    Get PDF
    Background The aim of this study was to compare centre of pressure (COP) characteristics between healthy adults with normal, planus or cavus feet who were allocated to groups based on reliable foot posture measurement techniques. Methods Ninety-two healthy adult participants (aged 18 to 45) were recruited and classified as either normal (n = 35), pes planus (n = 31) or pes cavus (n = 26) based on Foot Posture Index, Arch Index and normalised navicular height truncated measurements. Barefoot walking trials were conducted using an emed®-x 400 plantar pressure system (Novel GmbH, Munich, Germany). Average, maximum, minimum and range (difference between maximum and minimum) values were calculated for COP velocity and lateral-medial force index during loading response, midstance, terminal stance and pre-swing phases of stance. The COP excursion index was also calculated. One-way analyses of variance were used to compare the three foot posture groups. Results The cavus foot exhibited the slowest average and minimum COP velocity during terminal stance, but this pattern was reversed during pre-swing, when the cavus foot exhibited the fastest maximum COP velocity. The planus foot exhibited the smallest lateral medial force index range during terminal stance. There were no differences between the groups for COP excursion index. Conclusion These findings indicate that there are differences in COP characteristics between foot postures, which may represent different mechanisms for generating force to facilitate forward progression of the body during the propulsive phases of gait

    Laparoscopic sleeve gastrectomy in heart failure patients with left ventricular assist device

    Get PDF
    Background: There is limited data in the literature evaluating outcomes of bariatric surgery in severely obese patients with left ventricular assist device (LVAD) as a bridge to make them acceptable candidates for heart transplantation. This study aims to assess the safety and effectiveness of laparoscopic sleeve gastrectomy (LSG) in patients with previously implanted LVAD at our institution. Methods: All the patients with end-stage heart failure (ESHF) and implanted LVAD who underwent LSG from2013 to January 2017 were studied. Results: Seven patients with end stage heart failure (ESHF) and implanted LVAD were included. The median age and median preoperative BMI were 39 years (range: 26–62) and 43.6 kg/m2 (range 36.7–56.7), respectively. The median interval between LVAD implantation and LSG was 38 months (range 15–48). The median length of hospital stay was 9 days (rang: 6–23) out of which 4 patients had planned postoperative ICU admission. Thirty-day complications were noted in 5 patients (3 major and 2 minor) without any perioperative mortality. The median duration of follow-up was 24 months (range 2–30). At the last available follow-up, the median BMI, %EWL, and %TWL were 37 kg/m2 , 47%, and 16%, respectively. The median LVEF before LSG and at the last follow-up point (before heart transplant) was 19% (range 15–20) and 22% (range, 16–35), respectively. In addition, the median NYHA class improved from 3 to 2 after LSG. Three patients underwent successful heart transplantations. Conclusion: Patients with morbid obesity, ESHF, and implanted LVAD constitute a high-risk cohort. Our results with 7 patients and result from other studies (19 patients) suggested that bariatric surgery may be a reasonable option for LVAD patients with severe obesity. Bariatric surgery appears to provide significant weight loss in these patients and may improve candidacy for heart transplantation

    Step detection and activity recognition accuracy of seven physical activity monitors

    Get PDF
    The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear Armband Mini (Bodymedia). Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc) were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications
    corecore