1,530,369 research outputs found

    Critical evaluation of starch-based antibacterial nanocomposites as agricultural mulch films: Study on their interactions with water and light

    Get PDF
    In order to evaluate the potentiality of novel formulations based on starch to be used as agricultural mulch films, native and oxidized corn starch nanocomposites were prepared by extrusion using natural (Bent) and chitosan-modified bentonite (Bent-CS) fillers. The nanocomposite interactions with water were studied by means of moisture content (MC) determination, water solubility (WS), water vapor permeability (WVP), and contact angle (CA). The light transmission spectra were analyzed in order to determine the transparency and radiometric properties of films. Mechanical properties are also included and related with the cryo-fractured surface morphology observed by scanning electron microscopy (SEM). Finally, the antimicrobial action of developed nanocomposites was investigated against the phytopathogen bacterium Pseudomonas syringae pv tomato DC3000 (Psy). Results suggest that starch oxidation leads to a reduction in polarity and transparency. The incorporation of nanoclays improved water resistance but did not produce a significant effect in WVP and mechanical properties, and new strategies are required to improve the nanocomposite performance. However, the incorporation of Bent-CS exerted antibacterial activity on nanocomposites, which is an encouraging result.Fil: Merino, Danila. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; ArgentinaFil: Gutiérrez Carmona, Tomy José. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; ArgentinaFil: Mansilla, Andrea Yamila. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones Biológicas. Universidad Nacional de Mar del Plata. Facultad de Ciencias Exactas y Naturales. Instituto de Investigaciones Biológicas; ArgentinaFil: Casalongue, Claudia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones Biológicas. Universidad Nacional de Mar del Plata. Facultad de Ciencias Exactas y Naturales. Instituto de Investigaciones Biológicas; ArgentinaFil: Alvarez, Vera Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; Argentin

    Castor Roots In A Vertic Inceptisol

    Get PDF
    The root systems of 4 large and 4 small, mature castor (Ricinus communis) cv. Acuna plants were excavated. Large and small plants had similar root:shoot ratios but roots of small plants were longer per unit weight. Soil factors in or near the surface of the C1 horizon, probably higher gravel and carbonate content, apparently restricted root penetration

    Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts.</p> <p>Methods</p> <p>A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences.</p> <p>Results</p> <p>Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant.</p> <p>Conclusions</p> <p>The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.</p

    Development of a composite prototype with GFRP profiles and sandwich panels used as a floor module of an emergency house

    Get PDF
    A series of experimental tests carried out on a composite prototype to be used as a floor module of an emergency house is presented in this paper. The prototype comprises a frame structure formed by GFRP pultruded profiles, and two sandwich panels constituted by GFRP skins and a polyurethane foam core that configures the floor slab. The present work is part of the project “ClickHouse – Development of a prefabricated emergency house prototype made of composites materials” and investigates the feasibility of the assemblage process of the prototype and performance to support load conditions typical of residential houses. Furthermore, sandwich panels are also independently tested, analysing their flexural response, failure mechanisms and creep behaviour. Obtained results confirm the good performance of the prototype to be used as floor module of an emergency housing, with a good mechanical behaviour and the capacity of being transported to the disaster areas in the form of various low weight segments, and rapidly installed. Additionally, finite element simulations were carried out to assess the stress distributions in the prototype components and to evaluate the global behaviour and load transfer mechanism of the connections.Quadro de Referência Estratégica Nacional (QREN)FEDER funds through the Operational Program for Competitiveness Factors – COMPETE and the Portuguese National Agency of Innovation (ADI) - project no. 3896

    An investigation of the relationship between thermal imaging and digital thermometer

    Get PDF
    BACKGROUND: A number of research papers and theoretical clinical models summarising how temperature of the skin over the knee may be altered according to different pathological processes have been published. Thermal imaging (TI) is generally regarded as the ‘Gold’ or ‘reference’ standard for measuring skin temperature, however this technology is not widely accessible to most musculoskeletal physiotherapists working in clinical environments. This is largely due to the time required for analysis of the thermal images and high cost of the equipment. A digital thermometer (DT) is portable with a convenient display of results which could offer an inexpensive substitute. AIM: This study determined interchangeability between thermal imaging and a digital thermometer, using Bland-Altman limits of agreement, to determine skin temperature differences between right and left knees. METHOD: 71 healthy participants in the age group of 8 to 40 participated in the study. Data were collected in two phases. The first phase was as part of a public engagement event at the Lancashire Science Festival where school children were invited to learn about science. The second phase of data collection took place as part of a PhD study where staff and students at the university were recruited via electronic advert and posters displayed around the campus. All subjects were free from lower back or lower limb problems and had not had any previous lower limb surgery. RESULTS: Matched paired t tests showed no significant difference between temperature difference between right and left using DT and TI (t= 1.41, df= 69, P= 0.08). The DT and TI were interchangeable to measure knee skin temperature difference with a limit of agreement of -0.64 and 0.75; this limit of agreement is acceptable based on previous literature where skin temperature differences between affected and non-affected knees are equal to or greater than 1°C. CONCLUSION: This study concludes that an inexpensive handheld digital thermometer shows acceptable agreement with a thermal imaging camera. Clinically a handheld digital thermometer has the potential to play an important role in the localized assessment of skin temperature in physiotherapy and can offer an inexpensive substitute to thermal imaging; due to the massive difference in cost it is worth considering the adoption of digital thermometry in routine musculoskeletal physiotherapy practice

    Current activities in standardization of high-temperature, low-cycle-fatigue testing techniques in the United States

    Get PDF
    The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed

    Molecular Biomarkers for the Evaluation of Colorectal Cancer: Guideline From the American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology

    Get PDF
    OBJECTIVES: - To develop evidence-based guideline recommendations through a systematic review of the literature to establish standard molecular biomarker testing of colorectal cancer (CRC) tissues to guide epidermal growth factor receptor (EGFR) therapies and conventional chemotherapy regimens. METHODS: - The American Society for Clinical Pathology, College of American Pathologists, Association for Molecular Pathology, and American Society of Clinical Oncology convened an expert panel to develop an evidence-based guideline to establish standard molecular biomarker testing and guide therapies for patients with CRC. A comprehensive literature search that included more than 4,000 articles was conducted. RESULTS: - Twenty-one guideline statements were established. CONCLUSIONS: - Evidence supports mutational testing for EGFR signaling pathway genes, since they provide clinically actionable information as negative predictors of benefit to anti-EGFR monoclonal antibody therapies for targeted therapy of CRC. Mutations in several of the biomarkers have clear prognostic value. Laboratory approaches to operationalize CRC molecular testing are presented

    Volatile constituents of roasted tigernut oil (Cyperus esculentus L.).

    Get PDF
    BACKGROUND: Volatile compounds play a key role in determining the sensory appreciation of vegetable oils. In this study a systematic evaluation of odorants responsible for the characteristic flavour of roasted tigernut oil was carried out. RESULTS: A total of 75 odour-active volatiles were identified. From these, 13 aroma compounds showing high flavour dilution factors in the range of 16 to 128 were quantified by their odour activity values (OAVs). On the basis of high OAVs in oil, the following aroma compounds [vanillin (chocolate, sweet vanilla), 5-ethylfurfural (caramel, spicy), 2,3-dihydro-3,5-dihydroxy-6-methyl-4H-pyran-4-one (caramel), phenyl acetaldehyde (honey-like), ethanone, 1-(4-hydroxy-3-methoxyphenyl) (faint vanilla)] were elucidated as important contributors to the overall chocolate, sweet vanilla, butterscotch aroma of the oil. CONCLUSION: Odorants with high concentrations in the roasted tigernut oil such as 5-hydroxymethylfurfural, ethyl hexadecanoate, n-propyl-9,12-octadecadienoate gave relatively low OAVs, so their contributions to the overall orthonasal aroma impression of roasted tigernut oil can be assumed to be low. © 2012 Society of Chemical Industry
    corecore