30 research outputs found

    Characterizing the impact of urban emissions on regional aerosol particles: airborne measurements during the MEGAPOLI experiment

    Get PDF
    The MEGAPOLI (Megacities: Emissions, urban, regional and Global Atmospheric POLlution and climate effects, and Integrated tools for assessment and mitigation) experiment took place in July 2009. The aim of this campaign was to study the aging and reactions of aerosol and gas-phase emissions in the city of Paris. Three ground-based measurement sites and several mobile platforms including instrument equipped vehicles and the ATR-42 aircraft were involved. We present here the variations in particle- and gas-phase species over the city of Paris, using a combination of high-time resolution measurements aboard the ATR-42 aircraft. Particle chemical composition was measured using a compact time-of-flight aerosol mass spectrometer (C-ToF-AMS), giving detailed information on the non-refractory submicron aerosol species. The mass concentration of black carbon (BC), measured by a particle absorption soot photometer (PSAP), was used as a marker to identify the urban pollution plume boundaries. Aerosol mass concentrations and composition were affected by air-mass history, with air masses that spent longest time over land having highest fractions of organic aerosol and higher total mass concentrations. The Paris plume is mainly composed of organic aerosol (OA), BC, and nitrate aerosol, as well as high concentrations of anthropogenic gas-phase species such as toluene, benzene, and NO<sub>x</sub>. Using BC and CO as tracers for air-mass dilution, we observe the ratio of ΔOA / ΔBC and ΔOA / ΔCO increase with increasing photochemical age (−log(NO<sub>x</sub> / NO<sub>y</sub>)). Plotting the equivalent ratios of different organic aerosol species (LV-OOA, SV-OOA, and HOA) illustrate that the increase in OA is a result of secondary organic aerosol (SOA) formation. Within Paris the changes in the ΔOA / &Delta;CO are similar to those observed during other studies in London, Mexico City, and in New England, USA. Using the measured SOA volatile organic compounds (VOCs) species together with organic aerosol formation yields, we were able to predict ~50% of the measured organics. These airborne measurements during the MEGAPOLI experiment show that urban emissions contribute to the formation of OA and have an impact on aerosol composition on a regional scale

    Intracranial stimulation for children with epilepsy

    Get PDF
    OBJECTIVES: To evaluate the efficacy of intracranial stimulation to treat refractory epilepsy in children. METHODS: This is a retrospective analysis of a pilot study on all 8 children who had intracranial electrical stimulation for the investigation and treatment of refractory epilepsy at King's College Hospital between 2014 and 2015. Five children (one with temporal lobe epilepsy and four with frontal lobe epilepsy) had subacute cortical stimulation (SCS) for a period of 20-161 h during intracranial video-telemetry. Efficacy of stimulation was evaluated by counting interictal discharges and seizures. Two children had thalamic deep brain stimulation (DBS) of the centromedian nucleus (one with idiopathic generalized epilepsy, one with presumed symptomatic generalized epilepsy), and one child on the anterior nucleus (right fronto-temporal epilepsy). The incidence of interictal discharges was evaluated visually and quantified automatically. RESULTS: Among the three children with DBS, two had >60% improvement in seizure frequency and severity and one had no improvement. Among the five children with SCS, four showed improvement in seizure frequency (>50%) and one chid did not show improvement. Procedures were well tolerated by children. CONCLUSION: Cortical and thalamic stimulation appear to be effective and well tolerated in children with refractory epilepsy. SCS can be used to identify the focus and predict the effects of resective surgery or chronic cortical stimulation. Further larger studies are necessary

    Pediatric colloid cysts: a multinational, multicenter study. An IFNE-ISPN-ESPN collaboration

    Get PDF
    OBJECTIVE Colloid cysts (CCs) are rare at all ages, and particularly among children. The current literature on pediatric CC is limited, and often included in mixed adult/pediatric series. The goal of this multinational, multicenter study was to combine forces among centers and investigate the clinical course of pediatric CCs. METHODS A multinational, multicenter retrospective study was performed to attain a large sample size, focusing on CC diagnosis in patients younger than 18 years of age. Collected data included clinical presentation, radiological characteristics, treatment, and outcome. RESULTS One hundred thirty-four children with CCs were included. Patient age at diagnosis ranged from 2.4 to 18 years (mean 12.8 ± 3.4 years, median 13.2 years, interquartile range 10.3–15.4 years; 22% were \u3c 10 years of age). Twenty-two cases (16%) were diagnosed incidentally, including 48% of those younger than 10 years of age. Most of the other patients had symptoms related to increased intracranial pressure and hydrocephalus. The average follow-up duration for the entire group was 49.5 ± 45.8 months. Fifty-nine patients were initially followed, of whom 28 were eventually operated on at a mean of 19 ± 32 months later due to cyst growth, increasing hydrocephalus, and/or new symptoms. There was a clear correlation between larger cysts and symptomatology, acuteness of symptoms, hydrocephalus, and need for surgery. Older age was also associated with the need for surgery. One hundred three children (77%) underwent cyst resection, 60% using a purely endoscopic approach. There was 1 death related to acute hydrocephalus at presentation. Ten percent of operated patients had some form of complication, and 7.7% of operated cases required a shunt at some point during follow-up. Functional outcome was good; however, the need for immediate surgery was associated with educational limitations. Twenty operated cases (20%) experienced a recurrence of their CC at a mean of 38 ± 46 months after the primary surgery. The CC recurrence rate was 24% following endoscopic resection and 15% following open resections (p = 0.28). CONCLUSIONS CCs may present in all pediatric age groups, although most that are symptomatic present after the age of 10 years. Incidentally discovered cysts should be closely followed, as many may grow, leading to hydrocephalus and other new symptoms. Presentation of CC may be acute and may cause life-threatening conditions related to hydrocephalus, necessitating urgent treatment. The outcome of treated children with CCs is favorable

    Switching the uniaxial magnetic anisotropy by ion irradiation induced compensation

    Get PDF
    In the present work, the uniaxial magnetic anisotropy of GaMnAsP is modified by helium ion irradiation. According to the micro-magnetic parameters, e.g. resonance fields and anisotropy constants deduced from ferromagnetic resonance measurements, a rotation of the magnetic easy axis from out-of-plane [001] to in-plane [100] direction is achieved. From the application point of view, our work presents a novel avenue in modifying the uniaxial magnetic anisotropy in GaMnAsP with the possibility of lateral patterning by using lithography or focused ion beam

    Altimetry for the future: Building on 25 years of progress

    Get PDF
    In 2018 we celebrated 25 years of development of radar altimetry, and the progress achieved by this methodology in the fields of global and coastal oceanography, hydrology, geodesy and cryospheric sciences. Many symbolic major events have celebrated these developments, e.g., in Venice, Italy, the 15th (2006) and 20th (2012) years of progress and more recently, in 2018, in Ponta Delgada, Portugal, 25 Years of Progress in Radar Altimetry. On this latter occasion it was decided to collect contributions of scientists, engineers and managers involved in the worldwide altimetry community to depict the state of altimetry and propose recommendations for the altimetry of the future. This paper summarizes contributions and recommendations that were collected and provides guidance for future mission design, research activities, and sustainable operational radar altimetry data exploitation. Recommendations provided are fundamental for optimizing further scientific and operational advances of oceanographic observations by altimetry, including requirements for spatial and temporal resolution of altimetric measurements, their accuracy and continuity. There are also new challenges and new openings mentioned in the paper that are particularly crucial for observations at higher latitudes, for coastal oceanography, for cryospheric studies and for hydrology. The paper starts with a general introduction followed by a section on Earth System Science including Ocean Dynamics, Sea Level, the Coastal Ocean, Hydrology, the Cryosphere and Polar Oceans and the “Green” Ocean, extending the frontier from biogeochemistry to marine ecology. Applications are described in a subsequent section, which covers Operational Oceanography, Weather, Hurricane Wave and Wind Forecasting, Climate projection. Instruments’ development and satellite missions’ evolutions are described in a fourth section. A fifth section covers the key observations that altimeters provide and their potential complements, from other Earth observation measurements to in situ data. Section 6 identifies the data and methods and provides some accuracy and resolution requirements for the wet tropospheric correction, the orbit and other geodetic requirements, the Mean Sea Surface, Geoid and Mean Dynamic Topography, Calibration and Validation, data accuracy, data access and handling (including the DUACS system). Section 7 brings a transversal view on scales, integration, artificial intelligence, and capacity building (education and training). Section 8 reviews the programmatic issues followed by a conclusion

    Protocol for the development of a multidisciplinary clinical practice guideline for the care of patients with chronic subdural haematoma

    Get PDF
    Introduction: A common neurosurgical condition, chronic subdural haematoma (cSDH) typically affects older people with other underlying health conditions. The care of this potentially vulnerable cohort is often, however, fragmented and suboptimal. In other complex conditions, multidisciplinary guidelines have transformed patient experience and outcomes, but no such framework exists for cSDH. This paper outlines a protocol to develop the first comprehensive multidisciplinary guideline from diagnosis to long-term recovery with cSDH. Methods: The project will be guided by a steering group of key stakeholders and professional organisations and will feature patient and public involvement. Multidisciplinary thematic working groups will examine key aspects of care to formulate appropriate, patient-centered research questions, targeted with evidence review using the GRADE framework. The working groups will then formulate draft clinical recommendations to be used in a modified Delphi process to build consensus on guideline contents. Conclusions: We present a protocol for the development of a multidisciplinary guideline to inform the care of patients with a cSDH, developed by cross-disciplinary working groups and arrived at through a consensus-building process, including a modified online Delphi

    Laboratory spectroscopic calibration of infrared tunable laser spectrometers for the in situ sensing of the Earth and Martian atmospheres

    No full text
    This paper reports the laboratory spectroscopic calibration of near- and mid- infrared tunable laser spectrometers used to determine in situ trace gases in the middle atmosphere of the Earth or in development for the investigation of the Martian atmosphere. The use of infrared absorption spectroscopy to measure gas concentrations requires a proper knowledge of the rotation–vibration spectra of the targeted molecules as well as a proper investigation of the tunable laser spectral emission properties. This last point is of particular importance for the use of new-generation lasers like quantum-cascade lasers or room-temperature multi-quantum wells laser diodes emitting between 2 and 3 ÎŒm. Purposely, we have developed various laboratory tunable laser set-ups to obtain accurate line strengths and pressure-broadening coefficients of atmospheric molecules and to test the performances of cutting-edge laser technology for trace gas sensing. In this paper, the spectroscopic calibration work is described. Several atmospheric applications of tunable laser are reported to stress the impact on concentration retrieval of a proper spectroscopic calibration work

    Spectroscopy of CH4 with a difference-frequency generation laser at 3.3 micron for atmospheric applications

    No full text
    International audienceThe 3.25 micron spectral region is very suitable for the in situ sensing of CH4 in the troposphere and the lower stratosphere with light-weight laser sensors. Several transitions of the strong fundamental Μ 3 band of CH4 are revisited in this spectral region using an ultra-compact Difference-Frequency Generation (DFG) laser. Accurate intensities as well as self-broadening coefficients are reported for several manifolds that are particularly relevant to the monitoring of CH4. The study is extended to over hundred transitions reachable over the tunability range of the laser. Moreover, this DFG laser is the light source of a new, highly-compact CH4 laser spectrometer to be operated from weather balloon. The CH4 laser sensor is described and preliminary flight results are reported

    The AquaVIT-1 intercomparison of atmospheric water vapor measurement techniques

    Get PDF
    The AquaVIT-1 Intercomparison of Atmospheric Water Vapor Measurement Techniques was conducted at the aerosol and cloud simulation chamber AIDA at the Karlsruhe Institute of Technology, Germany, in October 2007. The overall objective was to intercompare state-of-the-art and prototype atmospheric hygrometers with each other and with independent humidity standards under controlled conditions. This activity was conducted as a blind intercomparison with coordination by selected referees. The effort was motivated by persistent discrepancies found in atmospheric measurements involving multiple instruments operating on research aircraft and balloon platforms, particularly in the upper troposphere and lower stratosphere where water vapor reaches its lowest atmospheric values (less than 10 ppm). With the AIDA chamber volume of 84 m3, multiple instruments analyzed air with a common water vapor mixing ratio, either by extracting air into instrument flow systems, locating instruments inside the chamber, or sampling the chamber volume optically. The intercomparison was successfully conducted over 10 days during which pressure, temperature, and mixing ratio were systematically varied (50 to 500 hPa, 185 to 243 K, and 0.3 to 152 ppm). In the absence of an accepted reference instrument, the reference value was taken to be the ensemble mean of a core subset of the measurements. For these core instruments, the agreement between 10 and 150 ppm of water vapor is considered good with variation about the reference value of about ±10% (±1σ). In the region of most interest between 1 and 10 ppm, the core subset agreement is fair with variation about the reference value of ±20% (±1σ). The upper limit of precision was also derived for each instrument from the reported data. These results indicate that the core instruments, in general, have intrinsic skill to determine unknown water vapor mixing ratios with an accuracy of at least ±20%. The implication for atmospheric measurements is that the substantially larger differences observed during in-flight intercomparisons stem from other factors associated with the moving platforms or the non-laboratory environment. The success of AquaVIT-1 provides a template for future intercomparison efforts with water vapor or other species that are focused on improving the analytical quality of atmospheric measurements on moving platforms
    corecore