198 research outputs found

    The Effect Of 3d Printing Machine Parameters In Extrusion Process Of Biocomposite Materials (Pmma And Ha) On Dimensional Accuracy

    Get PDF
    Bone implants are medical procedures involving replacement or reconstruction of missing or damaged bones with the patient's ones, natural substitutes or artificial substitutes. The widely used bone cement is a polymethylmethacrylate (PMMA) based composite material. To improve bioactivity, PMMA is combined with hydroxyapatite (HA). The manual formation can make bone implants during surgery. However, the method requires a longer operation time and raises the possibility of a higher error. Therefore, 3D printing technology is used to improve the quality of bone implants. One of the machines that can be used is the 3D printing machine, the property of the Product Design and Development Laboratory of Universitas Gadjah Mada. This machine needs to be tested to determine the accuracy of the prints, which is one indicator of product quality. Several machine parameters can be set in this machine setting. This study aims to determine the effect of three parameters, those are perimeter speed or edge print speed (20-40 mm / s), infill speed or inner print speed (50 - 70 mm / s), and fill angle or inner slope of inner printing (45 - 90 ° C). Before printing complex shapes, the machine was tested in advance with a more straightforward specimen design, which is a specimen design of flexural strength test. Response surface experiment design is used to determine the effect of three parameters on the dimensional accuracy which is measured through dimensional error. The results show that these three factors have no significant impact on the dimensional error, but the resulting error is still high. Therefore, it is necessary to adjust the design size before printing

    Optical pulse-shaping for internal cooling of molecules

    Full text link
    We consider the use of pulse-shaped broadband femtosecond lasers to optically cool rotational and vibrational degrees of freedom of molecules. Since this approach relies on cooling rotational and vibrational quanta by exciting an electronic transition, it is most easily applicable to molecules with similar ground and excited potential energy surfaces, such that the vibrational state is usually unchanged during electronic relaxation. Compared with schemes that cool rotations by exciting vibrations, this approach achieves internal cooling on the orders-of- magnitude faster electronic decay timescale and is potentially applicable to apolar molecules. For AlH+, a candidate species, a rate-equation simulation indicates that rovibrational equilibrium should be achievable in 8 \mu s. In addition, we report laboratory demonstration of optical pulse shaping with sufficient resolution and power for rotational cooling of AlH+

    Revisiting the SN1987A gamma-ray limit on ultralight axion-like particles

    Full text link
    We revise the bound from the supernova SN1987A on the coupling of ultralight axion-like particles (ALPs) to photons. In a core-collapse supernova, ALPs would be emitted via the Primakoff process, and eventually convert into gamma rays in the magnetic field of the Milky Way. The lack of a gamma-ray signal in the GRS instrument of the SMM satellite in coincidence with the observation of the neutrinos emitted from SN1987A therefore provides a strong bound on their coupling to photons. Due to the large uncertainty associated with the current bound, we revise this argument, based on state-of-the-art physical inputs both for the supernova models and for the Milky-Way magnetic field. Furthermore, we provide major amendments, such as the consistent treatment of nucleon-degeneracy effects and of the reduction of the nuclear masses in the hot and dense nuclear medium of the supernova. With these improvements, we obtain a new upper limit on the photon-ALP coupling: g_{a\gamma} < 5.3 x 10^{-12} GeV^{-1}, for m_a < 4.4 x 10^{-10} eV, and we also give its dependence at larger ALP masses. Moreover, we discuss how much the Fermi-LAT satellite experiment could improve this bound, should a close-enough supernova explode in the near future.Comment: Accepted for publication in JCAP (December 22nd, 2014

    Axion-like particle effects on the polarization of cosmic high-energy gamma sources

    Get PDF
    Various satellite-borne missions are being planned whose goal is to measure the polarization of a large number of gamma-ray bursts (GRBs). We show that the polarization pattern predicted by current models of GRB emission can be drastically modified by the existence of very light axion-like particles (ALPs), which are present in many extensions of the Standard Model of particle physics. Basically, the propagation of photons emitted by a GRB through cosmic magnetic fields with a domain-like structure induces photon-ALP mixing, which is expected to produce a strong modification of the original photon polarization. Because of the random orientation of the magnetic field in each domain, this effect strongly depends on the orientation of the photon line of sight. As a consequence, photon-ALP conversion considerably broadens the original polarization distribution. Searching for such a peculiar feature through future high-statistics polarimetric measurements is therefore a new opportunity to discover very light ALPs.Comment: Final version (21 pages, 8 eps figures). Matches the version published on JCAP. Added a Section on the effects of cosmic expansion on photon-ALP conversions. Figures modified to take into account this effect. References updated. Conclusions unchanged

    Detecting early kidney damage in horses with colic by measuring matrix metalloproteinase -9 and -2, other enzymes, urinary glucose and total proteins

    Get PDF
    BACKGROUND: The aim of the study was to investigate urine matrix metalloproteinase (MMP-2 and -9) activity, alkaline phosphatase/creatinine (U-AP/Cr) and gamma-glutamyl-transpeptidase/creatinine (U-GGT/Cr) ratios, glucose concentration, and urine protein/creatinine (U-Prot/Cr) ratio and to compare data with plasma MMP-2 and -9 activity, cystatin-C and creatinine concentrations in colic horses and healthy controls. Horses with surgical colic (n = 5) were compared to healthy stallions (n = 7) that came for castration. Blood and urine samples were collected. MMP gelatinolytic activity was measured by zymography. RESULTS: We found out that horses with colic had significantly higher urinary MMP-9 complex and proMMP-9 activities than horses in the control group. Colic horses also had higher plasma MMP-2 activity than the control horses. Serum creatinine, although within reference range, was significantly higher in the colic horses than in the control group. There was no significant increase in urinary alkaline phosphatase, gamma-glutamyltranspeptidase or total proteins in the colic horses compared to the control group. A human cystatin-C test (Dako Cytomation latex immunoassay(® )based on turbidimetry) did not cross react with equine cystatin-C. CONCLUSION: The results indicate that plasma MMP-2 may play a role in the pathogenesis of equine colic and urinary MMP-9 in equine kidney damage

    The manipulation of massive ro-vibronic superpositions using time-frequency-resolved coherent anti-Stokes Raman scattering (TFRCARS): from quantum control to quantum computing

    Full text link
    Molecular ro-vibronic coherences, joint energy-time distributions of quantum amplitudes, are selectively prepared, manipulated, and imaged in Time-Frequency-Resolved Coherent Anti-Stokes Raman Scattering (TFRCARS) measurements using femtosecond laser pulses. The studies are implemented in iodine vapor, with its thermally occupied statistical ro-vibrational density serving as initial state. The evolution of the massive ro-vibronic superpositions, consisting of 1000 eigenstates, is followed through two-dimensional images. The first- and second-order coherences are captured using time-integrated frequency-resolved CARS, while the third-order coherence is captured using time-gated frequency-resolved CARS. The Fourier filtering provided by time integrated detection projects out single ro-vibronic transitions, while time-gated detection allows the projection of arbitrary ro-vibronic superpositions from the coherent third-order polarization. Beside the control and imaging of chemistry, the controlled manipulation of massive quantum coherences suggests the possibility of quantum computing. We argue that the universal logic gates necessary for arbitrary quantum computing - all single qubit operations and the two-qubit controlled-NOT (CNOT) gate - are available in time resolved four-wave mixing in a molecule. The molecular rotational manifold is naturally "wired" for carrying out all single qubit operations efficiently, and in parallel. We identify vibronic coherences as one example of a naturally available two-qubit CNOT gate, wherein the vibrational qubit controls the switching of the targeted electronic qubit.Comment: PDF format. 59 pages, including 22 figures. To appear in Chemical Physic

    Laparoscopy in management of appendicitis in high-, middle-, and low-income countries: a multicenter, prospective, cohort study.

    Get PDF
    BACKGROUND: Appendicitis is the most common abdominal surgical emergency worldwide. Differences between high- and low-income settings in the availability of laparoscopic appendectomy, alternative management choices, and outcomes are poorly described. The aim was to identify variation in surgical management and outcomes of appendicitis within low-, middle-, and high-Human Development Index (HDI) countries worldwide. METHODS: This is a multicenter, international prospective cohort study. Consecutive sampling of patients undergoing emergency appendectomy over 6 months was conducted. Follow-up lasted 30 days. RESULTS: 4546 patients from 52 countries underwent appendectomy (2499 high-, 1540 middle-, and 507 low-HDI groups). Surgical site infection (SSI) rates were higher in low-HDI (OR 2.57, 95% CI 1.33-4.99, p = 0.005) but not middle-HDI countries (OR 1.38, 95% CI 0.76-2.52, p = 0.291), compared with high-HDI countries after adjustment. A laparoscopic approach was common in high-HDI countries (1693/2499, 67.7%), but infrequent in low-HDI (41/507, 8.1%) and middle-HDI (132/1540, 8.6%) groups. After accounting for case-mix, laparoscopy was still associated with fewer overall complications (OR 0.55, 95% CI 0.42-0.71, p < 0.001) and SSIs (OR 0.22, 95% CI 0.14-0.33, p < 0.001). In propensity-score matched groups within low-/middle-HDI countries, laparoscopy was still associated with fewer overall complications (OR 0.23 95% CI 0.11-0.44) and SSI (OR 0.21 95% CI 0.09-0.45). CONCLUSION: A laparoscopic approach is associated with better outcomes and availability appears to differ by country HDI. Despite the profound clinical, operational, and financial barriers to its widespread introduction, laparoscopy could significantly improve outcomes for patients in low-resource environments. TRIAL REGISTRATION: NCT02179112

    Global economic burden of unmet surgical need for appendicitis

    Get PDF
    Background: There is a substantial gap in provision of adequate surgical care in many low-and middle-income countries. This study aimed to identify the economic burden of unmet surgical need for the common condition of appendicitis. Methods: Data on the incidence of appendicitis from 170 countries and two different approaches were used to estimate numbers of patients who do not receive surgery: as a fixed proportion of the total unmet surgical need per country (approach 1); and based on country income status (approach 2). Indirect costs with current levels of access and local quality, and those if quality were at the standards of high-income countries, were estimated. A human capital approach was applied, focusing on the economic burden resulting from premature death and absenteeism. Results: Excess mortality was 4185 per 100 000 cases of appendicitis using approach 1 and 3448 per 100 000 using approach 2. The economic burden of continuing current levels of access and local quality was US 92492millionusingapproach1and92 492 million using approach 1 and 73 141 million using approach 2. The economic burden of not providing surgical care to the standards of high-income countries was 95004millionusingapproach1and95 004 million using approach 1 and 75 666 million using approach 2. The largest share of these costs resulted from premature death (97.7 per cent) and lack of access (97.0 per cent) in contrast to lack of quality. Conclusion: For a comparatively non-complex emergency condition such as appendicitis, increasing access to care should be prioritized. Although improving quality of care should not be neglected, increasing provision of care at current standards could reduce societal costs substantially
    corecore