8 research outputs found

    Quantifying the effects of iodine contrast media on standardised uptake values of FDG PET/CT images : an anthropomorphic phantom study.

    Get PDF
    This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality

    A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source

    No full text
    The effective use of near water equivalent organic plastic scintillators (OPS) for radiation dosimetry with high-energy sources under laboratory conditions is recognized. In this work, an OPS-based dosimeter using a photodiode combined with improved solid state detection and signal processing techniques has been developed; it offers the potential for the construction of a stable and fully portable dosimeter which will extend the useful range of measurement beyond the usual MeV area and provide reliable readings down to sub-‘100 keV’ X-ray energy levels. In these experiments, the instrument described has been used for the dosimetry of INTRABEAM intraoperative radiotherapy (IORT) equipment at distances as low as 1.8 mm from the effective source, i.e., 0.2 mm from the X-ray probe surface. Comparison is shown with dosimetry measurements made using the calibrated reference ion chamber supplied by the IORT equipment manufacturer

    Origins of the observed asymmetry in out-of-field dose from a linac fitted with an external micro-MLC

    No full text
    Objective Recently, Taylor et al. reported that use of the BrainLAB m3 microMLC, for stereotactic radiosurgery, results in a decreased out-of-field dose in the direction of leaf-motion compared to the outof- field dose measured in the direction orthogonal to leaf-motion [1]. It was recommended that, where possible, patients should be treated with their superior–inferior axes aligned with the microMLCs leafmotion direction, to minimise out-of-field doses [1]. This study aimed, therefore, to examine the causes of this asymmetry in outof- field dose and, in particular, to establish that a similar recommendation need not be made for radiotherapy treatments delivered by linear accelerators without external micro-collimation systems. Methods Monte Carlo simulations were used to study out-of-field dose from different linear accelerators (the Varian Clinacs 21iX and 600C and the Elekta Precise) with and without internal MLCs and external microMLCs [2]. Results Simulation results for the Varian Clinac 600C linear accelerator with BrainLAB m3 microMLC confirm Taylor et als [1] published experimental data. The out-of-field dose in the leaf motion direction is deposited by lower energy (more obliquely scattered) photons than the out-of-field dose in the orthogonal direction. Linear accelerators without microMLCs produce no asymmetry in out-offield dose. Conclusions The asymmetry in out-of-field dose previously measured by Taylor et al. [1] results from the shielding characteristics of the BrainLAB m3 microMLC device and is not produced by the linear accelerator to which it is attached

    Enhancement of radiation effects by gold nanoparticles for superficial radiation therapy

    No full text
    Iodinated contrast agents, which are routinely used to improve contrast in x-ray diagnostic radiography, have been successfully proven to enhance radiation effects in kilovoltage x-ray radiation therapy beams. The studies determined the influence of iodine on the level of radiation biotoxicity to cells as an indicator of the radiation dose enhancement. The use of other high-atomic-number materials such as gold nanoparticles (AuNPs) may also provide advantages in terms of radiation dose enhancement. In this work AuNPs have been used for the enhancement of radiation effects on bovine aortic endothelial cells of superficial x-ray radiation therapy and megavoltage electron radiation therapy beams. Results reveal an increase of cell damage with increasing concentration of AuNPs. At 1 mM concentration of AuNPs, enhancement of radiation peaked at 25 times for a kilovoltage x-ray beam. AuNPs showed similar effects on electron beams but to a lesser extent. This study showed that AuNPs can be used to enhance the effect of radiation doses from kilovoltage x-ray radiation therapy and megavoltage electron radiation therapy beams. In the prevailing clinical circumstances, wherein radiation therapy dose is constrained by normal tissue tolerance, this enhancement could in the future be used to improve local control in superficial x-ray treatments, megavoltage electron beam radiation therapy, microbeam radiation therapy, and intraoperative irradiation using kilovoltage x-rays or megavoltage electron beams. Moreover, the value of this work also stems from the fact that the damage to the endothelial cells lining the highly vasculature structure of tumors deprives tumors of their oxygen and nutrients supply and enhances the efficiency of radiation therapy treatment, where it has been proven that more of the AuNPs injected into animals ends up into the blood than in the tumor

    Responses of herbaceous plants to urban air pollution: Effects on growth, phenology and leaf surface characteristics

    Get PDF
    Vehicle exhaust emissions are a dominant feature of urban environments and are widely believed to have detrimental effects on plants. The effects of diesel exhaust emissions on 12 herbaceous species were studied with respect to growth, flower development, leaf senescence and leaf surface wax characteristics. A diesel generator was used to produce concentrations of nitrogen oxides (NOx) representative of urban conditions, in solardome chambers. Annual mean NOx concentrations ranged from 77 nl l−l to 98 nl l−1, with NO:NO2 ratios of 1.4–2.2, providing a good experimental simulation of polluted roadside environments. Pollutant exposure resulted in species-specific changes in growth and phenology, with a consistent trend for accelerated senescence and delayed flowering. Leaf surface characteristics were also affected; contact angle measurements indicated changes in surface wax structure following pollutant exposure. The study demonstrated clearly the potential for realistic levels of vehicle exhaust pollution to have direct adverse effects on urban vegetation

    A Worldwide analysis of within-canopy variations in leaf structural, chemical and physiological traits across plant functional types

    No full text
    Extensive within-canopy light gradients importantly affect the photosynthetic productivity of leaves in different canopy positions and lead to light-dependent increases in foliage photosynthetic capacity per area (AA). However, the controls on AA variations by changes in underlying traits are poorly known. We constructed an unprecedented worldwide database including 831 within-canopy gradients with standardized light estimates for 304 species belonging to major vascular plant functional types, and analyzed within-canopy variations in 12 key foliage structural, chemical and physiological traits by quantitative separation of the contributions of different traits to photosynthetic acclimation. Although the light-dependent increase in AA is surprisingly similar in different plant functional types, they differ fundamentally in the share of the controls on AA by constituent traits. Species with high rates of canopy development and leaf turnover, exhibiting highly dynamic light environments, actively change AA by nitrogen reallocation among and partitioning within leaves. By contrast, species with slow leaf turnover exhibit a passive AA acclimation response, primarily determined by the acclimation of leaf structure to growth light. This review emphasizes that different combinations of traits are responsible for within-canopy photosynthetic acclimation in different plant functional types, and solves an old enigma of the role of mass- vs area-based traits in vegetation acclimation.21 page(s