103 research outputs found

    Does a novel X-ray imaging technology provide a substantial radiation dose reduction for patients in trans-catheter aortic valve implantation procedures?

    Get PDF
    Purpose: Modern interventional X-ray equipment employs image processing to permit reduction in radiation whilst retaining sufficient image quality. The aim of this study was to investigate whether our recently-installed system (AlluraClarity, Philips Healthcare) which contains advanced real-time image noise reduction algorithms and anatomy-specific X-ray optimization (beam filtering, grid switch, pulse width, spot size, detector and image processing engine), affected patient procedure dose and overall procedure duration in routine trans-catheter aortic valve implantation (TAVI) procedures. Methods: Patient dose for 42 TAVI patients from the AlluraClarity cardiac catheterisation lab and from a reference system (Axiom Artis, Siemens Healthcare) in the same cardiology department was recorded. Median values from the two X-ray systems were compared using the Wilcoxon statistical test. Results: Total patient procedure dose medians were 4016 and 7088 cGy cm2 from the AlluraClarity and reference systems respectively. AlluraClarity median patient doses were 3405 cGy cm2 and 783.5 cGy cm2 from fluoroscopy and digital image acquisition respectively. Reference median patient doses were 4928 cGy cm2 and 2511 cGy cm2 from fluoroscopy and digital image acquisition respectively. All differences in patient dose were significant at the 5% level. Median total fluoroscopy times [min:sec] were 19:57 and 20:20 for the AlluraClarity and reference systems respectively. Conclusion: The AlluraClarity cardiac catheterisation lab had 43% lower total patient procedure dose for TAVI patients than the reference lab; fluoroscopy and digital image acquisition doses were 31% and 69% lower respectively. In terms of total fluoroscopy time, there was no statistically significant difference between the two labs

    Image quality based x-ray dose control in cardiac imaging

    Get PDF
    An automated closed-loop dose control system balances the radiation dose delivered to patients and the quality of images produced in cardiac x-ray imaging systems. Using computer simulations, this study compared two designs of automatic x-ray dose control in terms of the radiation dose and quality of images produced. The first design, commonly in x-ray systems today, maintained a constant dose rate at the image receptor. The second design maintained a constant image quality in the output images. A computer model represented patients as a polymethylmetacrylate phantom (which has similar x-ray attenuation to soft tissue), containing a detail representative of an artery filled with contrast medium. The model predicted the entrance surface dose to the phantom and contrast to noise ratio of the detail as an index of image quality. Results showed that for the constant dose control system, phantom dose increased substantially with phantom size (x5 increase between 20cm and 30 cm thick phantom), yet the image quality decreased by 43% for the same thicknesses. For the constant quality control, phantom dose increased at a greater rate with phantom thickness (>x10 increase between 20 cm and 30 cm phantom). Image quality based dose control could tailor the x-ray output to just achieve the quality required, which would reduce dose to patients where the current dose control produces images of too high quality. However, maintaining higher levels of image quality for large patients would result in a significant dose increase over current practice

    Machine vision image quality measurement in cardiac x-ray imaging

    Get PDF
    The purpose of this work is to report on a machine vision approach for the automated measurement of x-ray image contrast of coronary arteries filled with iodine contrast media during interventional cardiac procedures. A machine vision algorithm was developed that creates a binary mask of the principal vessels of the coronary artery tree by thresholding a standard deviation map of the direction image of the cardiac scene derived using a Frangi filter. Using the mask, average contrast is calculated by tting a Gaussian model to the greyscale profile orthogonal to the vessel centre line at a number of points along the vessel. The algorithm was applied to sections of single image frames from 30 left and 30 right coronary artery image sequences from different patients. Manual measurements of average contrast were also performed on the same images. A Bland-Altman analysis indicates good agreement between the two methods with 95% confidence intervals -0.046 to +0.048 with a mean bias of 0.001. The machine vision algorithm has the potential of providing real-time context sensitive information so that radiographic imaging control parameters could be adjusted on the basis of clinically relevant image content

    How much noise can be added in cardiac X-ray imaging without loss in perceived image quality?

    Get PDF
    Dynamic X-ray imaging systems are used for interventional cardiac procedures to treat coronary heart disease. X-ray settings are controlled automatically by specially-designed X-ray dose control mechanisms whose role is to ensure an adequate level of image quality is maintained with an acceptable radiation dose to the patient. Current commonplace dose control designs quantify image quality by performing a simple technical measurement directly from the image. However, the utility of cardiac X-ray images is in their interpretation by a cardiologist during an interventional procedure, rather than in a technical measurement. With the long term goal of devising a clinically-relevant image quality metric for an intelligent dose control system, we aim to investigate the relationship of image noise with clinical professionals’ perception of dynamic image sequences. Computer-generated noise was added, in incremental amounts, to angiograms of five different patients selected to represent the range of adult cardiac patient sizes. A two alternative forced choice staircase experiment was used to determine the amount of noise which can be added to a patient image sequences without changing image quality as perceived by clinical professionals. Twenty-five viewing sessions (five for each patient) were completed by thirteen observers. Results demonstrated scope to increase the noise of cardiac X-ray images by up to 21% ± 8% before it is noticeable by clinical professionals. This indicates a potential for 21% radiation dose reduction since X-ray image noise and radiation dose are directly related; this would be beneficial to both patients and personnel

    Selecting stimuli parameters for video quality studies based on perceptual similarity distances

    Get PDF
    This work presents a methodology to optimize the selection of multiple parameter levels of an image acquisition, degradation, or post-processing process applied to stimuli intended to be used in a subjective image or video quality assessment (QA) study. It is known that processing parameters (e.g. compression bit-rate) or technical quality measures (e.g. peak signal-to-noise ratio, PSNR) are often non-linearly related to human quality judgment, and the model of either relationship may not be known in advance. Using these approaches to select parameter levels may lead to an inaccurate estimate of the relationship between the parameter and subjective quality judgments – the system’s quality model. To overcome this, we propose a method for modeling the relationship between parameter levels and perceived quality distances using a paired comparison parameter selection procedure in which subjects judge the perceived similarity in quality. Our goal is to enable the selection of evenly sampled parameter levels within the considered quality range for use in a subjective QA study. This approach is tested on two applications: (1) selection of compression levels for laparoscopic surgery video QA study, and (2) selection of dose levels for an interventional X-ray QA study. Subjective scores, obtained from the follow-up single stimulus QA experiments conducted with expert subjects who evaluated the selected bit-rates and dose levels, were roughly equidistant in the perceptual quality space - as intended. These results suggest that a similarity judgment task can help select parameter values corresponding to desired subjective quality levels

    GARFIELD-AF model for prediction of stroke and major bleeding in atrial fibrillation: a Danish nationwide validation study.

    Get PDF
    OBJECTIVES: To externally validate the accuracy of the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) model against existing risk scores for stroke and major bleeding risk in patients with non-valvular AF in a population-based cohort. DESIGN: Retrospective cohort study. SETTING: Danish nationwide registries. PARTICIPANTS: 90 693 patients with newly diagnosed non-valvular AF were included between 2010 and 2016, with follow-up censored at 1 year. PRIMARY AND SECONDARY OUTCOME MEASURES: External validation was performed using discrimination and calibration plots. C-statistics were compared with CHA2DS2VASc score for ischaemic stroke/systemic embolism (SE) and HAS-BLED score for major bleeding/haemorrhagic stroke outcomes. RESULTS: Of the 90 693 included, 51 180 patients received oral anticoagulants (OAC). Overall median age (Q1, Q3) were 75 (66-83) years and 48 486 (53.5%) were male. At 1-year follow-up, a total of 2094 (2.3%) strokes/SE, 2642 (2.9%) major bleedings and 10 915 (12.0%) deaths occurred. The GARFIELD-AF model was well calibrated with the predicted risk for stroke/SE and major bleeding. The discriminatory value of GARFIELD-AF risk model was superior to CHA2DS2VASc for predicting stroke in the overall cohort (C-index: 0.71, 95% CI: 0.70 to 0.72 vs C-index: 0.67, 95% CI: 0.66 to 0.68, p<0.001) as well as in low-risk patients (C-index: 0.64, 95% CI: 0.59 to 0.69 vs C-index: 0.57, 95% CI: 0.53 to 0.61, p=0.007). The GARFIELD-AF model was comparable to HAS-BLED in predicting the risk of major bleeding in patients on OAC therapy (C-index: 0.64, 95% CI: 0.63 to 0.66 vs C-index: 0.64, 95% CI: 0.63 to 0.65, p=0.60). CONCLUSION: In a nationwide Danish cohort with non-valvular AF, the GARFIELD-AF model adequately predicted the risk of ischaemic stroke/SE and major bleeding. Our external validation confirms that the GARFIELD-AF model was superior to CHA2DS2VASc in predicting stroke/SE and comparable with HAS-BLED for predicting major bleeding

    Ash generation and distribution from the April-May 2010 eruption of Eyjafjallajökull, Iceland

    Get PDF
    The 39-day long eruption at the summit of Eyjafjallajökull volcano in April–May 2010 was of modest size but ash was widely dispersed. By combining data from ground surveys and remote sensing we show that the erupted material was 4.8±1.2·1011 kg (benmoreite and trachyte, dense rock equivalent volume 0.18±0.05 km3). About 20% was lava and water-transported tephra, 80% was airborne tephra (bulk volume 0.27 km3) transported by 3–10 km high plumes. The airborne tephra was mostly fine ash (diameter <1000 µm). At least 7·1010 kg (70 Tg) was very fine ash (<28 µm), several times more than previously estimated via satellite retrievals. About 50% of the tephra fell in Iceland with the remainder carried towards south and east, detected over ~7 million km2 in Europe and the North Atlantic. Of order 1010 kg (2%) are considered to have been transported longer than 600–700 km with <108 kg (<0.02%) reaching mainland Europe

    Tinnitus in elderly patients and prognosis of mild-to-moderate congestive heart failure: a cross-sectional study with a long-term extension of the clinical follow-up

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The complex mechanism responsible for tinnitus, a symptom highly prevalent in elderly patients, could involve an impaired control of the microcirculation of the inner ear, particularly in patients with poor blood pressure control and impaired left ventricular (LV) function.</p> <p>Methods</p> <p>In order to define the relationship between the presence of tinnitus and the severity and clinical prognosis of mild-to-moderate chronic heart failure (CHF) in a large population of elderly patients (N = 958), a cross-sectional study was conducted with a long-term extension of the clinical follow-up. Blood pressure, echocardiographic parameters, brain natriuretic peptide (BNP), hospitalization, and mortality for CHF were measured. Multivariate logistic regression analysis was used to assess the association between the presence of tinnitus and some of the prognostic determinants of heart failure.</p> <p>Results</p> <p>The presence of tinnitus was ascertained in 233 patients (24.3%; mean age 74.9 ± 6 years) and was associated with reduced systolic and diastolic blood pressure (123.1 ± 16/67.8 ± 9 vs 125.9 ± 15/69.7 ± 9; <it>P </it>= .027/<it>P </it>= .006), reduced LV ejection fraction (LVEF%; 43.6 ± 15 vs 47.9 ± 14%, <it>P </it>= .001), and increased BNP plasma levels (413.1 ± 480 vs 286.2 ± 357, <it>P </it>= .013) in comparison to patients without symptoms. The distribution of CHF functional class was shifted toward a greater severity of the disease in patients with tinnitus. Combined one-year mortality and hospitalization for CHF (events/year) was 1.43 ± 0.2 in patients with tinnitus and 0.83 ± 0.1 in patients without tinnitus, with an adjusted hazard ratio (HR) of 0.61 (95% confidence interval (CI): 0.37 to 0.93, <it>P </it><.002).</p> <p>Conclusions</p> <p>Our preliminary data indirectly support the hypothesis that tinnitus is associated with a worse CHF control in elderly patients and can have some important clinical implications for the early identification of patients who deserve a more aggressive management of CHF.</p

    Ice sheets as a missing source of silica to the polar oceans

    Get PDF
    Ice sheets play a more important role in the global silicon cycle than previously appreciated. Input of dissolved and amorphous particulate silica into natural waters stimulates the growth of diatoms. Here we measure dissolved and amorphous silica in Greenland Ice Sheet meltwaters and icebergs, demonstrating the potential for high ice sheet export. Our dissolved and amorphous silica flux is 0.20 (0.06-0.79) Tmol year(-1), ∼50% of the input from Arctic rivers. Amorphous silica comprises >95% of this flux and is highly soluble in sea water, as indicated by a significant increase in dissolved silica across a fjord salinity gradient. Retreating palaeo ice sheets were therefore likely responsible for high dissolved and amorphous silica fluxes into the ocean during the last deglaciation, reaching values of ∼5.5 Tmol year(-1), similar to the estimated export from palaeo rivers. These elevated silica fluxes may explain high diatom productivity observed during the last glacial-interglacial period

    Fourteen sequence variants that associate with multiple sclerosis discovered by meta-analysis informed by genetic correlations

    Get PDF
    A meta-analysis of publicly available summary statistics on multiple sclerosis combined with three Nordic multiple sclerosis cohorts (21,079 cases, 371,198 controls) revealed seven sequence variants associating with multiple sclerosis, not reported previously. Using polygenic risk scores based on public summary statistics of variants outside the major histocompatibility complex region we quantified genetic overlap between common autoimmune diseases in Icelanders and identified disease clusters characterized by autoantibody presence/absence. As multiple sclerosis-polygenic risk scores captures the risk of primary biliary cirrhosis and vice versa (P = 1.6 x 10(-7), 4.3 x 10(-9)) we used primary biliary cirrhosis as a proxy-phenotype for multiple sclerosis, the idea being that variants conferring risk of primary biliary cirrhosis have a prior probability of conferring risk of multiple sclerosis. We tested 255 variants forming the primary biliary cirrhosis-polygenic risk score and found seven multiple sclerosis-associating variants not correlated with any previously established multiple sclerosis variants. Most of the variants discovered are close to or within immune-related genes. One is a low-frequency missense variant in TYK2, another is a missense variant in MTHFR that reduces the function of the encoded enzyme affecting methionine metabolism, reported to be dysregulated in multiple sclerosis brain.publishedVersio
    • …
    corecore