9 research outputs found

    Comparing proton momentum distributions in A=2A=2 and 3 nuclei via 2^2H 3^3H and 3^3He (e,ep)(e, e'p) measurements

    Full text link
    We report the first measurement of the (e,ep)(e,e'p) reaction cross-section ratios for Helium-3 (3^3He), Tritium (3^3H), and Deuterium (dd). The measurement covered a missing momentum range of 40pmiss55040 \le p_{miss} \le 550 MeV/c/c, at large momentum transfer (Q21.9\langle Q^2 \rangle \approx 1.9 (GeV/c/c)2^2) and xB>1x_B>1, which minimized contributions from non quasi-elastic (QE) reaction mechanisms. The data is compared with plane-wave impulse approximation (PWIA) calculations using realistic spectral functions and momentum distributions. The measured and PWIA-calculated cross-section ratios for 3^3He/d/d and 3^3H/d/d extend to just above the typical nucleon Fermi-momentum (kF250k_F \approx 250 MeV/c/c) and differ from each other by 20%\sim 20\%, while for 3^3He/3^3H they agree within the measurement accuracy of about 3\%. At momenta above kFk_F, the measured 3^3He/3^3H ratios differ from the calculation by 20%50%20\% - 50\%. Final state interaction (FSI) calculations using the generalized Eikonal Approximation indicate that FSI should change the 3^3He/3^3H cross-section ratio for this measurement by less than 5\%. If these calculations are correct, then the differences at large missing momenta between the 3^3He/3^3H experimental and calculated ratios could be due to the underlying NNNN interaction, and thus could provide new constraints on the previously loosely-constrained short-distance parts of the NNNN interaction.Comment: 8 pages, 3 figures (4 panels

    ATHENA detector proposal — a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

    Get PDF
    ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges

    Investigating Broadband Variability of the TeV Blazar 1ES 1959+650

    Get PDF
    We summarize broadband observations of the TeV-emitting blazar 1ES 1959+650, including optical R-band observations by the robotic telescopes Super-LOTIS and iTelescope, UV observations by Swift Ultraviolet and Optical Telescope, X-ray observations by the Swift X-ray Telescope, high-energy gamma-ray observations with the Fermi Large Area Telescope, and very-high-energy (VHE) gamma-ray observations by VERITAS above 315 GeV, all taken between 2012 April 17 and 2012 June 1 (MJD 56034 and 56079). The contemporaneous variability of the broadband spectral energy distribution is explored in the context of a simple synchrotron self Compton (SSC) model. In the SSC emission scenario, we find that the parameters required to represent the high state are significantly different than those in the low state. Motivated by possible evidence of gas in the vicinity of the blazar, we also investigate a reflected emission model to describe the observed variability pattern. This model assumes that the non-thermal emission from the jet is reflected by a nearby cloud of gas, allowing the reflected emission to re-enter the blob and produce an elevated gamma-ray state with no simultaneous elevated synchrotron flux. The model applied here, although not required to explain the observed variability pattern, represents one possible scenario which can describe the observations. As applied to an elevated VHE state of 66% of the Crab Nebula flux, observed on a single night during the observation period, the reflected emission scenario does not support a purely leptonic non-thermal emission mechanism. The reflected emission model does, however, predict a reflected photon field with sufficient energy to enable elevated gamma-ray emission via pion production with protons of energies between 10 and 100 TeV

    Comparing proton momentum distributions in A = 2 and 3 nuclei via 2H 3H and 3He (e,e′p) measurements

    No full text

    ATHENA detector proposal — a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

    No full text
    International audienceATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges

    ATHENA detector proposal — a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

    No full text
    International audienceATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges

    ATHENA detector proposal — a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

    No full text
    International audienceATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges
    corecore