60 research outputs found

    Epitaxial Zn(x)Fe(3-x)O(4) Thin Films: A Spintronic Material with Tunable Electrical and Magnetic Properties

    Full text link
    The ferrimagnetic spinel oxide Zn(x)Fe(3-x)O(4) combines high Curie temperature and spin polarization with tunable electrical and magnetic properties, making it a promising functional material for spintronic devices. We have grown epitaxial thin films with 0<=x<=0.9 on MgO(001) substrates with excellent structural properties both in pure Ar atmosphere and an Ar/O2 mixture by laser molecular beam epitaxy. We find that the electrical conductivity and the saturation magnetization can be tuned over a wide range during growth. Our extensive characterization of the films provides a clear picture of the underlying physics of this spinel ferrimagnet with antiparallel Fe moments on the A and B sublattice: (i) Zn substitution removes both Fe3+ moments from the A sublattice and itinerant charge carriers from the B sublattice, (ii) growth in finite oxygen partial pressure generates Fe vacancies on the B sublattice also removing itinerant charge carriers, and (iii) application of both Zn substitution and excess oxygen results in a compensation effect as Zn substitution partially removes the Fe vacancies. A decrease (increase) of charge carrier density results in a weakening (strengthening) of double exchange and thereby a decrease (increase) of conductivity and the saturation magnetization. This scenario is confirmed by the observation that the saturation magnetization scales with the longitudinal conductivity. The combination of tailored films with semiconductor materials such as ZnO in multi-functional heterostructures seems to be particularly appealing.Comment: 13 pages, 8 figures, Hall effect data removed, anti-phase boundary discussion added, accepted for publication in PRB79 (2009

    Disproportionate left atrial myopathy in heart failure with preserved ejection fraction among participants of the PROMIS-HFpEF study

    Get PDF
    Impaired left atrial (LA) function in heart failure with preserved ejection fraction (HFpEF) is associated with adverse outcomes. A subgroup of HFpEF may have LA myopathy out of proportion to left ventricular (LV) dysfunction; therefore, we sought to characterize HFpEF patients with disproportionate LA myopathy. In the prospective, multicenter, Prevalence of Microvascular Dysfunction in HFpEF study, we defined disproportionate LA myopathy based on degree of LA reservoir strain abnormality in relation to LV myopathy (LV global longitudinal strain [GLS]) by calculating the residuals from a linear regression of LA reservoir strain and LV GLS. We evaluated associations of disproportionate LA myopathy with hemodynamics and performed a plasma proteomic analysis to identify proteins associated with disproportionate LA myopathy; proteins were validated in an independent sample. Disproportionate LA myopathy correlated with better LV diastolic function but was associated with lower stroke volume reserve after passive leg raise independent of atrial fibrillation (AF). Additionally, disproportionate LA myopathy was associated with higher pulmonary artery systolic pressure, higher pulmonary vascular resistance, and lower coronary flow reserve. Of 248 proteins, we identified and validated 5 proteins (involved in cardiomyocyte stretch, extracellular matrix remodeling, and inflammation) that were associated with disproportionate LA myopathy independent of AF. In HFpEF, LA myopathy may exist out of proportion to LV myopathy. Disproportionate LA myopathy is a distinct HFpEF subtype associated with worse hemodynamics and a distinct proteomic signature, independent of AF

    Association of epicardial adipose tissue with proteomics, coronary flow reserve, cardiac structure and function, and quality of life in heart failure with preserved ejection fraction: insights from the PROMIS-HFpEF study

    Get PDF
    Aim: Epicardial adipose tissue (EAT) may play a role in the pathophysiology of heart failure with preserved ejection fraction (HFpEF). We investigated associations of EAT with proteomics, coronary flow reserve (CFR), cardiac structure and function, and quality of life (QoL) in the prospective multinational PROMIS-HFpEF cohort.Methods and results: Epicardial adipose tissue was measured by echocardiography in 182 patients and defined as increased if ≥9 mm. Proteins were measured using high-throughput proximity extension assays. Microvascular dysfunction was evaluated with Doppler-based CFR, cardiac structural and functional indices with echocardiography and QoL by Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients with increased EAT (n = 54; 30%) had higher body mass index (32 [28-40] vs. 27 [23-30] kg/m2 ; p Conclusion: Increased EAT was associated with cardiac structural alterations and proteins expressing adiposity, inflammation, lower insulin sensitivity and endothelial dysfunction related to HFpEF pathology, probably driven by general obesity. Potential local mechanical or paracrine effects mediated by EAT remain to be elucidated.</p

    Near-field magneto-caloritronic nanoscopy on ferromagnetic nanostructures

    Get PDF
    Near-field optical microscopy by means of infrared photocurrent mapping has rapidly developed in recent years. In this letter we introduce a near-field induced contrast mechanism arising when a conducting surface, exhibiting a magnetic moment, is exposed to a nanoscale heat source. The magneto-caloritronic response of the sample to near-field excitation of a localized thermal gradient leads to a contrast determined by the local state of magnetization. By comparing the measured electric response of a magnetic reference sample with numerical simulations we derive an estimate of the field enhancement and the corresponding temperature profile induced on the sample surface.This work was supported by the Deutsche Forschungsgemeinschaft through grant HE 2063/5-1 to JH. The work also received funding from the ERC synergy grant No. 61011

    Approaching disorder-free transport in high-mobility conjugated polymers.

    Get PDF
    Conjugated polymers enable the production of flexible semiconductor devices that can be processed from solution at low temperatures. Over the past 25 years, device performance has improved greatly as a wide variety of molecular structures have been studied. However, one major limitation has not been overcome; transport properties in polymer films are still limited by pervasive conformational and energetic disorder. This not only limits the rational design of materials with higher performance, but also prevents the study of physical phenomena associated with an extended π-electron delocalization along the polymer backbone. Here we report a comparative transport study of several high-mobility conjugated polymers by field-effect-modulated Seebeck, transistor and sub-bandgap optical absorption measurements. We show that in several of these polymers, most notably in a recently reported, indacenodithiophene-based donor-acceptor copolymer with a near-amorphous microstructure, the charge transport properties approach intrinsic disorder-free limits at which all molecular sites are thermally accessible. Molecular dynamics simulations identify the origin of this long sought-after regime as a planar, torsion-free backbone conformation that is surprisingly resilient to side-chain disorder. Our results provide molecular-design guidelines for 'disorder-free' conjugated polymers.We gratefully acknowledge financial support from the Engineering and Physical Sciences Research Council (EPSRC) through a programme grant (EP/G060738/1) and the Technology Strategy Board (TSB) (PORSCHED project). D. Venkateshvaran acknowledges financial support from the Cambridge Commonwealth Trust through a Cambridge International Scholarship. K. Broch acknowledges post-doctoral fellowship support from the German Research Foundation (DFG). Mateusz Zelazny acknowledges funding from the NanoDTC in Cambridge. The work in Mons was supported by the European Commission / Région Wallonne (FEDER – Smartfilm RF project), the Interuniversity Attraction Pole program of the Belgian Federal Science Policy Office (PAI 7/05), Programme d’Excellence de la Région Wallonne (OPTI2MAT project) and FNRS-FRFC. D.B. and J.C. are FNRS Research Fellows.This is the accepted manuscript. The final version's available from Nature at http://www.nature.com/nature/journal/vaop/ncurrent/full/nature13854.html

    Disproportionate left atrial myopathy in heart failure with preserved ejection fraction among participants of the PROMIS-HFpEF study

    Get PDF
    Impaired left atrial (LA) function in heart failure with preserved ejection fraction (HFpEF) is associated with adverse outcomes. A subgroup of HFpEF may have LA myopathy out of proportion to left ventricular (LV) dysfunction; therefore, we sought to characterize HFpEF patients with disproportionate LA myopathy. In the prospective, multicenter, Prevalence of Microvascular Dysfunction in HFpEF study, we defined disproportionate LA myopathy based on degree of LA reservoir strain abnormality in relation to LV myopathy (LV global longitudinal strain [GLS]) by calculating the residuals from a linear regression of LA reservoir strain and LV GLS. We evaluated associations of disproportionate LA myopathy with hemodynamics and performed a plasma proteomic analysis to identify proteins associated with disproportionate LA myopathy; proteins were validated in an independent sample. Disproportionate LA myopathy correlated with better LV diastolic function but was associated with lower stroke volume reserve after passive leg raise independent of atrial fibrillation (AF). Additionally, disproportionate LA myopathy was associated with higher pulmonary artery systolic pressure, higher pulmonary vascular resistance, and lower coronary flow reserve. Of 248 proteins, we identified and validated 5 proteins (involved in cardiomyocyte stretch, extracellular matrix remodeling, and inflammation) that were associated with disproportionate LA myopathy independent of AF. In HFpEF, LA myopathy may exist out of proportion to LV myopathy. Disproportionate LA myopathy is a distinct HFpEF subtype associated with worse hemodynamics and a distinct proteomic signature, independent of AF

    Roadmap on energy harvesting materials

    Get PDF
    Ambient energy harvesting has great potential to contribute to sustainable development and address growing environmental challenges. Converting waste energy from energy-intensive processes and systems (e.g. combustion engines and furnaces) is crucial to reducing their environmental impact and achieving net-zero emissions. Compact energy harvesters will also be key to powering the exponentially growing smart devices ecosystem that is part of the Internet of Things, thus enabling futuristic applications that can improve our quality of life (e.g. smart homes, smart cities, smart manufacturing, and smart healthcare). To achieve these goals, innovative materials are needed to efficiently convert ambient energy into electricity through various physical mechanisms, such as the photovoltaic effect, thermoelectricity, piezoelectricity, triboelectricity, and radiofrequency wireless power transfer. By bringing together the perspectives of experts in various types of energy harvesting materials, this Roadmap provides extensive insights into recent advances and present challenges in the field. Additionally, the Roadmap analyses the key performance metrics of these technologies in relation to their ultimate energy conversion limits. Building on these insights, the Roadmap outlines promising directions for future research to fully harness the potential of energy harvesting materials for green energy anytime, anywhere

    The pulmonary capillary wedge pressure accurately reflects both normal and elevated left atrial pressure.

    No full text
    BACKGROUND: Pulmonary capillary wedge pressure (PCWP) is routinely used as an indirect measure of the left atrial pressure (LAP), although the accuracy of this estimate, especially under pathological hemodynamic conditions, remains controversial. OBJECTIVES: The aim of this prospective study was to investigate the reliability of PCWP for the evaluation of LAP under different hemodynamic conditions. METHODS: Simultaneous left and right heart catheterization data of 117 patients with pure mitral stenosis, obtained before and immediately after percutaneous mitral comissurotomy, were analyzed. RESULTS: A strong correlation and agreement between PCWP and LAP measurements was demonstrated (correlation coefficient = 0.97, mean bias +/- CI, 0.3 +/- -3.7 to 4.2 mm Hg). Comparison of measurements performed within a 5-minute interval and those performed simultaneously revealed that simultaneous pressure acquisition yielded better agreement between the 2 methods (bias +/- CI, 1.82 +/- 1.98 mm Hg). In contrast to previous observations, the discrepancy between the 2 measures did not increase with elevated PCWP. Multiple regression analysis failed to identify hemodynamic confounders of the discrepancy between the 2 pressures. The ability of PCWP to distinguish between normal and elevated LAP (cutoff set at 12 and 15 mm Hg, respectively), as tested by receiver operating characteristics analysis, demonstrated a remarkably high diagnostic accuracy (area under the curve: 0.989 and 0.996, respectively). CONCLUSIONS: Although the described limits of agreement may not allow the interchangeability of PCWP and LAP, especially at lower pressure ranges, our data support the clinical use of PCWP as a robust and accurate estimate of LAP
    corecore