5,465 research outputs found

    Surface-plasmon-polariton wave propagation guided by a metal slab in a sculptured nematic thin film

    Full text link
    Surface-plasmon-polariton~(SPP) wave propagation guided by a metal slab in a periodically nonhomogeneous sculptured nematic thin film~(SNTF) was studied theoretically. The morphologically significant planes of the SNTF on both sides of the metal slab could either be aligned or twisted with respect to each other. The canonical boundary-value problem was formulated, solved for SPP-wave propagation, and examined to determine the effect of slab thickness on the multiplicity and the spatial profiles of SPP waves. Decrease in slab thickness was found to result in more intense coupling of two metal/SNTF interfaces. But when the metal slab becomes thicker, the coupling between the two interfaces reduces and SPP waves localize to one of the two interfaces. The greater the coupling between the two metal/SNTF interfaces, the smaller is the phase speed.Comment: 17 page

    Secure and Robust Fragile Watermarking Scheme for Medical Images

    Get PDF
    Over the past decade advances in computer-based communication and health services, the need for image security becomes urgent to address the requirements of both safety and non-safety in medical applications. This paper proposes a new fragile watermarking based scheme for image authentication and self-recovery for medical applications. The proposed scheme locates image tampering as well as recovers the original image. A host image is broken into 4×4 blocks and Singular Value Decomposition (SVD) is applied by inserting the traces of block wise SVD into the Least Significant Bit (LSB) of the image pixels to figure out the transformation in the original image. Two authentication bits namely block authentication and self-recovery bits were used to survive the vector quantization attack. The insertion of self-recovery bits is determined with Arnold transformation, which recovers the original image even after a high tampering rate. SVD-based watermarking information improves the image authentication and provides a way to detect different attacked area. The proposed scheme is tested against different types of attacks such are text removal attack, text insertion attack, and copy and paste attack

    Responsive, Integrity, Morality and Fairness Law Enforcement as Social Change Instrument

    Full text link
    This article reviews the essence of law enforcement as social change instrument. Law in the context of Indonesia that embrace democratic system is upholding the justice values in it that fairness principles for all Indonesian people. As positive law in a legal state, law enforcement is required to be professional, proportional, good, fair, and wisely so in accordance with the rules of expediency, kindness and equality in the law itself. The outcomes of the research indicate that law and community cannot be separated, for law the community is a resource that gives life (to nature) and move the law. The communities live the law with the values, ideas, concepts. And also contribute the community to implement the law

    Efficient Security and Authentication for Edge-Based Internet of Medical Things

    Get PDF
    Internet of Medical Things (IoMT)-driven smart health and emotional care is revolutionizing the healthcare industry by embracing several technologies related to multimodal physiological data collection, communication, intelligent automation, and efficient manufacturing. The authentication and secure exchange of electronic health records (EHRs), comprising of patient data collected using wearable sensors and laboratory investigations, is of paramount importance. In this article, we present a novel high payload and reversible EHR embedding framework to secure the patient information successfully and authenticate the received content. The proposed approach is based on novel left data mapping (LDM), pixel repetition method (PRM), RC4 encryption, and checksum computation. The input image of size MimesNM imes N is upscaled by using PRM that guarantees reversibility with lesser computational complexity. The binary secret data are encrypted using the RC4 encryption algorithm and then the encrypted data are grouped into 3-bit chunks and converted into decimal equivalents. Before embedding, these decimal digits are encoded by LDM. To embed the shifted data, the cover image is divided into 2imes22 imes 2 blocks and then in each block, two digits are embedded into the counter diagonal pixels. For tamper detection and localization, a checksum digit computed from the block is embedded into one of the main diagonal pixels. A fragile logo is embedded into the cover images in addition to EHR to facilitate early tamper detection. The average peak signal to noise ratio (PSNR) of the stego-images obtained is 41.95 dB for a very high embedding capacity of 2.25 bits per pixel. Furthermore, the embedding time is less than 0.2 s. Experimental results reveal that our approach outperforms many state-of-the-art techniques in terms of payload, imperceptibility, computational complexity, and capability to detect and localize tamper. All the attributes affirm that the proposed scheme is a potential candidate for providing better security and authentication solutions for IoMT-based smart health

    Determining the electronic performance limitations in top-down fabricated Si nanowires with mean widths down to 4 nm

    Get PDF
    Silicon nanowires have been patterned with mean widths down to 4 nm using top-down lithography and dry etching. Performance-limiting scattering processes have been measured directly which provide new insight into the electronic conduction mechanisms within the nanowires. Results demonstrate a transition from 3-dimensional (3D) to 2D and then 1D as the nanowire mean widths are reduced from 12 to 4 nm. The importance of high quality surface passivation is demonstrated by a lack of significant donor deactivation, resulting in neutral impurity scattering ultimately limiting the electronic performance. The results indicate the important parameters requiring optimization when fabricating nanowires with atomic dimensions

    ESROCOS: a robotic operating system for space and terrestrial applications

    Get PDF
    ESROCOS (http://www.h2020-esrocos.eu) is a European Project in the frame of the PERASPERA SRC, (http://www.h2020-peraspera.eu/), targeting the design of a Robot Control Operating Software (RCOS) for space robotics applications. The goal of the ESROCOS project is to provide an open-source framework to assist in the development of flight software for space robots, providing adequate features and performance with space-grade Reliability, Availability, Maintainability and Safety (RAMS) properties. This paper presents the ESROCOS project and summarizes the approach and the current status

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Full text link
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5<η<2.21.5 < \mid\eta\mid < 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 μ\murad pitch arranged in eight η\eta-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO2_{2} 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 μ\murad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ±\pm 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 ±\pm 1.6 (stat)] μ\murad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by \sim 10 μ\murad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ±\pm 2.5 stat] μ\murad is measured, consistent with the expected resolution of strip-pitch/12\sqrt{12} = 131.3 μ\murad. Other η\eta-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference adde

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848
    corecore