830 research outputs found

    Changes in visual function after intraocular pressure reduction using antiglaucoma medications

    Get PDF
    Purpose To evaluate the change in visual function after starting glaucoma treatment and correlate this to a decrease in intraocular pressure (IOP) in primary open-angle glaucoma patients.Methods A prospective, randomized clinical trial was carried out involving 54 glaucoma patients (54 eyes). After inclusion, patients randomly received timolol maleate 0.5%, brimonidine tartrate 0.2%, or travoprost 0.004% in one randomly selected eye. Patients underwent Goldmann applanation tonometry, visual acuity test, standard automated perimetry (SAP), visual quality perception test (visual analogue scale), and contrast sensitivity (CS) test, in a random order before and after the 4-week glaucoma treatment.Results There were statistically significant changes in IOP (mean change [standard deviation], 7.8 [3.6] mmHg, P 0.001), SAP mean deviation index (0.84 [2.45] dB, P = 0.02), visual quality perception (0.56 [1.93], P = 0.045), and CS at frequencies of 12 cycles/degree (0.10 [0.37], P = 0.03) and 18 cycles/degree (0.18 [0.42], P = 0.02) after the 4-week treatment when compared with baseline. No statistically significant differences were found between the treatment groups in visual function changes after treatment (P > 0.40). No significant correlations between IOP reduction and changes in visual function were found (P > 0.30).Conclusions Visual quality perception, visual field mean deviation index, and CS at higher frequencies improve after starting glaucoma therapy. However, no correlation was found between IOP reduction and changes in visual function, and no differences were found in visual function when the three medications studied were compared. Eye (2009) 23, 1081-1085; doi:10.1038/eye.2008.226; published online 1 August 2008Universidade Federal de São Paulo, Glaucoma Serv, Dept Ophthalmol, BR-01404001 São Paulo, BrazilUniversidade Federal de São Paulo, Glaucoma Serv, Dept Ophthalmol, BR-01404001 São Paulo, BrazilWeb of Scienc

    Value of bronchoscopy after EUS in the preoperative assessment of patients with esophageal cancer at or above the carina

    Get PDF
    Introduction: Esophageal cancer is an aggressive disease with a strong tendency to infiltrate into surrounding structures. The aim of the present study is to determine the additional value of bronchoscopy for detecting invasion of the tracheobronchial tree after endoscopic ultrasonography (EUS) in the preoperative assessment of patients with esophageal cancer at or above the carina. Materials and Methods: Between January 1997 and December 2006, 104 patients were analyzed for histologically proven esophageal cancer at or above the carina. All patients underwent both EUS and bronchoscopy (with biopsy on indication) in the preoperative assessment of local resectability. Results and Discussion: After extensive diagnostic workup, 58 of 104 patients (56%) were eligible for potentially curative esophagectomy; nine of these 58 patients (9/58, 15%) appeared to be incurable peroperatively because of ingrowth in the tracheobronchial tree (five patients), ingrowth in other vital structures (two patients) or distant metastases (two patients). Of the 46 non-operable patients, local irresectability (T-stage 4) was identified in 26 patients (26/46, 57%) due to invasion of vital structures on EUS: invasion of the aorta in six patients, invasion of the lung in 11 patients; in 12 patients invasion of the tracheobronchial tree was described, which was confirmed by bronchoscopy in only five patients. No patients with T4 were identified by bronchoscopy alone. Conclusion: For patients with esophageal tumors at or above the carina, no additional value of bronchoscopy (with biopsy on indication) to exclude invasion of the tracheobronchial tree was seen after EUS in a specialized centre. Although based on relatively small numbers, we conclude that bronchoscopy is not indicated if no invasion of the airways is identified on EUS

    The effect of cataract on early stage glaucoma detection using spatial and temporal contrast sensitivity tests

    Get PDF
    Background: To investigate the effect of cataract on the ability of spatial and temporal contrast sensitivity tests used to detect early glaucoma. Methods: Twenty-seven glaucoma subjects with early cataract (mean age 60 ±10.2 years) which constituted the test group were recruited together with twenty-seven controls (cataract only) matched for age and cataract type from a primary eye care setting. Contrast sensitivity to flickering gratings at 20 Hz and stationary gratings with and without glare, were measured for 0.5, 1.5 and 3 cycles per degree (cpd) in central vision. Perimetry and structural measurements with the Heidelberg Retinal Tomograph (HRT) were also performed. Results: After considering the effect of cataract, contrast sensitivity to stationary gratings was reduced in the test group compared with controls with a statistically significant mean difference of 0.2 log units independent of spatial frequency. The flicker test showed a significant difference between test and control group at 1.5 and 3 cpd (p = 0.019 and p = 0.011 respectively). The percentage of glaucoma patients who could not see the temporal modulation was much higher compared with their cataract only counterparts. A significant correlation was found between the reduction of contrast sensitivity caused by glare and the Glaucoma Probability Score (GPS) as measured with the HRT (p<0.005). Conclusions: These findings indicate that both spatial and temporal contrast sensitivity tests are suitable for distinguishing between vision loss as a consequence of glaucoma and vision loss caused by cataract only. The correlation between glare factor and GPS suggests that there may be an increase in intraocular stray light in glaucoma

    Practical recommendations for measuring rates of visual field change in glaucoma

    Get PDF
    To date, there has been a lack of evidence-based guidance on the frequency of visual field examinations required to identify clinically meaningful rates of change in glaucoma. The objective of this perspective is to provide practical recommendations for this purpose. The primary emphasis is on the period of time and number of examinations required to measure various rates of change in mean deviation (MD) with adequate statistical power. Empirical data were used to obtain variability estimates of MD while statistical modelling techniques derived the required time periods to detect change with various degrees of visual field variability. We provide the frequency of examinations per year required to detect different amounts of change in 2, 3 and 5 years. For instance, three examinations per year are required to identify an overall change in MD of 4 dB over 2 years in a patient with average visual field variability. Recommendations on other issues such as examination type, strategy and quality are also made

    Optic disc classification by the Heidelberg Retina Tomograph and by physicians with varying experience of glaucoma

    Get PDF
    PurposeTo compare the diagnostic accuracy of the Heidelberg Retina Tomograph's (HRT) Moorfields regression analysis (MRA) and glaucoma probability score (GPS) with that of subjective grading of optic disc photographs performed by ophthalmologists with varying experience of glaucoma and by ophthalmology residents.MethodsDigitized disc photographs and HRT images from 97 glaucoma patients with visual field defects and 138 healthy individuals were classified as either within normal limits (WNL), borderline (BL), or outside normal limits (ONL). Sensitivity and specificity were compared for MRA, GPS, and the physicians. Analyses were also made according to disc size and for advanced visual field loss.ResultsForty-five physicians participated. When BL results were regarded as normal, sensitivity was significantly higher (P<5%) for both MRA and GPS compared with the average physician, 87%, 79%, and 62%, respectively. Specificity ranged from 86% for MRA to 97% for general ophthalmologists, but the differences were not significant. In eyes with small discs, sensitivity was 75% for MRA, 60% for the average doctor, and 25% for GPS; in eyes with large discs, sensitivity was 100% for both GPS and MRA, but only 68% for physicians.ConclusionOur results suggest that sensitivity of MRA is superior to that of the average physician, but not that of glaucoma experts. MRA correctly classified all eyes with advanced glaucoma and showed the best sensitivity in eyes with small optic discs
    corecore