134 research outputs found

    Support vector machines for young and older gait classification using inertial sensor kinematics at minimum toe clearance

    Get PDF
    Paper originally presented at: 10th EAI International Conference on Body Area Networks (BODYNETS 2015) Sydney, Australia, 28-30 Sept, 201

    Identifying Gait Deficits in Stroke Patients Using Inertial Sensors

    Get PDF
    Falls remain a significant problem for stroke patients. Tripping, the main cause of falls, occurs when there is insufficient clearance between the foot and ground. Based on an individual’s gait deficits, different joint angles and coordination patterns are necessary to achieve adequate foot clearance during walking. However, gait deficits are typically only quantified in a research or clinical setting, and it would be helpful to use wearable devices – such as accelerometers – to quantify gait disorders in real-world situations. Therefore, the objective of this project was to understand gait characteristics that influence the risk of tripping, and to detect these characteristics using accelerometers. Thirty-five participants with a range of walking abilities performed normal walking and attempted to avoid tripping on an unexpected object while gait characteristics were quantified using motion capture techniques and accelerometers. Multiple regression was used to identify the relationship between joint coordination and foot clearance, and multiple analysis of variance was used to determine characteristics of gait that differ between demographic groups, as well as those that enable obstacle avoidance. Machine learning techniques were employed to detect joint angles and the risk of tripping from patterns in accelerometer signals. Measures of foot clearance that represent toe height throughout swing instead of at a single time point are more sensitive to changes in joint coordination, with hip-knee coordination during midswing having the greatest effect. Participants with a history of falls or stroke perform worse than older non-fallers and young adults on many factors related to falls risk, however, there are no differences in the ability to avoid an unexpected obstacle between these groups. Individuals with an inability to avoid an obstacle have lower scores on functional evaluations, exhibit limited sagittal plane joint range of motion during swing, and adopt a conservative walking strategy. Machine learning processes can be used to predict knee range of motion and classify individuals at risk for tripping based on an ankle-worn accelerometer. This work is significant because a portable device that detects gait characteristics relevant to the risk of tripping without expensive motion capture technology may reduce the risk of falls for stroke patients

    Classifying Lower Extremity Muscle Fatigue During Walking Using Machine Learning and Inertial Sensors

    Get PDF
    Fatigue in lower extremity musculature is associated with decline in postural stability, motor performance and alters normal walking patterns in human subjects. Automated recognition of lower extremity muscle fatigue condition may be advantageous in early detection of fall and injury risks. Supervised machine learning methods such as Support Vector Machines (SVM) have been previously used for classifying healthy and pathological gait patterns and also for separating old and young gait patterns. In this study we explore the classification potential of SVM in recognition of gait patterns utilizing an inertial measurement unit associated with lower extremity muscular fatigue. Both kinematic and kinetic gait patterns of 17 participants (29±11 years) were recorded and analyzed in normal and fatigued state of walking. Lower extremities were fatigued by performance of a squatting exercise until the participants reached 60% of their baseline maximal voluntary exertion level. Feature selection methods were used to classify fatigue and no-fatigue conditions based on temporal and frequency information of the signals. Additionally, influences of three different kernel schemes (i.e., linear, polynomial, and radial basis function) were investigated for SVM classification. The results indicated that lower extremity muscle fatigue condition influenced gait and loading responses. In terms of the SVM classification results, an accuracy of 96% was reached in distinguishing the two gait patterns (fatigue and no-fatigue) within the same subject using the kinematic, time and frequency domain features. It is also found that linear kernel and RBF kernel were equally good to identify intra-individual fatigue characteristics. These results suggest that intra-subject fatigue classification using gait patterns from an inertial sensor holds considerable potential in identifying “at-risk” gait due to muscle fatigue

    Assessment of Foot Signature Using Wearable Sensors for Clinical Gait Analysis and Real-Time Activity Recognition

    Get PDF
    Locomotion is one of the most important abilities of humans. Actually, gait locomotion provides mobility, and symbolizes freedom and independence. However, gait can be affected by several pathologies, due to aging, neurodegenerative disease, or trauma. The evaluation and treatment of mobility diseases thus requires clinical gait assessment, which is commonly done by using either qualitative analysis based on subjective observations and questionnaires, or expensive analysis established in complex motion laboratories settings. This thesis presents a new wearable system and algorithmic methods for gait assessment in natural conditions, addressing the limitations of existing methods. The proposed system provides quantitative assessment of gait performance through simple and precise outcome measures. The system includes wireless inertial sensors worn on the foot, that record data unobtrusively over long periods of time without interfering with subject's walking. Signal processing algorithms are presented for the automatic calibration and online virtual alignment of sensor signals, the detection of temporal parameters and gait phases, and the estimation of 3D foot kinematics during gait based on fusion methods and biomechanical assumptions. The resulting 3D foot trajectory during one gait cycle is defined as Foot Signature, by analogy with hand-written signature. Spatio-temporal parameters of interest in clinical assessment are derived from foot signature, including commonly parameters, such as stride velocity and gait cycle time, as well as original parameters describing inner-stance phases of gait, foot clearance, and turning. Algorithms based on expert and machine learning methods have been also adapted and implemented in real-time to provide input features to recognize locomotion activities including level walking, stairs, and ramp locomotion. Technical validation of the presented methods against gold standard systems was carried out using experimental protocols on subjects with normal and abnormal gait. Temporal aspects and quantitative estimation of foot-flat were evaluated against pressure insoles in subjects with ankle treatments during long-term gait. Furthermore, spatial parameters and foot clearance were compared in young and elderly persons to data obtained from an optical motion capture system during forward gait trials at various speeds. Finally, turning was evaluated in children with cerebral palsy and people with Parkinson's disease against optical motion capture data captured during timed up and go and figure-of-8 tests. Overall, the results demonstrated that the presently proposed system and methods were precise and accurate, and showed agreement with reference systems as well as with clinical evaluations of subjects' mobility disease using classical scores. Currently, no other methods based on wearable sensors have been validated with such precision to measure foot signature and subsequent parameters during unconstrained walking. Finally, we have used the proposed system in a large-scale clinical application involving more than 1800 subjects from age 7 to 77. This analysis provides reference data of common and original gait parameters, as well as their relationship with walking speed, and allows comparisons between different groups of subjects with normal and abnormal gait. Since the presented methods can be used with any foot-worn inertial sensors, or even combined with other systems, we believe our work to open the door to objective and quantitative routine gait evaluations in clinical settings for supporting diagnosis. Furthermore, the present studies have high potential for further research related to rehabilitation based on real-time devices, the investigation of new parameters' significance and their association with various mobility diseases, as well as for the evaluation of clinical interventions

    Ann Biomed Eng

    Get PDF
    Fatigue in lower extremity musculature is associated with decline in postural stability, motor performance and alters normal walking patterns in human subjects. Automated recognition of lower extremity muscle fatigue condition may be advantageous in early detection of fall and injury risks. Supervised machine learning methods such as support vector machines (SVMs) have been previously used for classifying healthy and pathological gait patterns and also for separating old and young gait patterns. In this study we explore the classification potential of SVM in recognition of gait patterns utilizing an inertial measurement unit associated with lower extremity muscular fatigue. Both kinematic and kinetic gait patterns of 17 participants (29 \uc2\ub1 11 years) were recorded and analyzed in normal and fatigued state of walking. Lower extremities were fatigued by performance of a squatting exercise until the participants reached 60% of their baseline maximal voluntary exertion level. Feature selection methods were used to classify fatigue and no-fatigue conditions based on temporal and frequency information of the signals. Additionally, influences of three different kernel schemes (i.e., linear, polynomial, and radial basis function) were investigated for SVM classification. The results indicated that lower extremity muscle fatigue condition influenced gait and loading responses. In terms of the SVM classification results, an accuracy of 96% was reached in distinguishing the two gait patterns (fatigue and no-fatigue) within the same subject using the kinematic, time and frequency domain features. It is also found that linear kernel and RBF kernel were equally good to identify intra-individual fatigue characteristics. These results suggest that intra-subject fatigue classification using gait patterns from an inertial sensor holds considerable potential in identifying "at-risk" gait due to muscle fatigue.L30 AG022963/AG/NIA NIH HHS/United StatesL30-AG022963-04/AG/NIA NIH HHS/United StatesR01-OH009222/OH/NIOSH CDC HHS/United States2015-03-01T00:00:00Z24081829PMC394349

    Automatic recognition of gait patterns in human motor disorders using machine learning: A review

    Get PDF
    Background: automatic recognition of human movement is an effective strategy to assess abnormal gait patterns. Machine learning approaches are mainly applied due to their ability to work with multidimensional nonlinear features. Purpose: to compare several machine learning algorithms employed for gait pattern recognition in motor disorders using discriminant features extracted from gait dynamics. Additionally, this work highlights procedures that improve gait recognition performance. Methods: we conducted an electronic literature search on Web of Science, IEEE, and Scopus, using “human recognition”, “gait patterns’’, and “feature selection methods” as relevant keywords. Results: analysis of the literature showed that kernel principal component analysis and genetic algorithms are efficient at reducing dimensional features due to their ability to process nonlinear data and converge to global optimum. Comparative analysis of machine learning performance showed that support vector machines (SVMs) exhibited higher accuracy and proper generalization for new instances. Conclusions: automatic recognition by combining dimensional data reduction, cross-validation and normalization techniques with SVMs may offer an objective and rapid tool for investigating the subject's clinical status. Future directions comprise the real-time application of these tools to drive powered assistive devices in free-living conditions.This work was supported by the FCT - Fundação para a Ciência e Tecnologia - with the reference scholarship SFRH/BD/108309/2015, and the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 - Programa Operacional Competitividade e Internacionalização (POCI) - with the reference project POCI-01-0145-FEDER-006941. Also, this work was partially supported by grant RYC-2014-16613 by Spanish Ministry of Economy and Competitiveness

    Gait rehabilitation monitor

    Get PDF
    This work presents a simple wearable, non-intrusive affordable mobile framework that allows remote patient monitoring during gait rehabilitation, by doctors and physiotherapists. The system includes a set of 2 Shimmer3 9DoF Inertial Measurement Units (IMUs), Bluetooth compatible from Shimmer, an Android smartphone for collecting and primary processing of data and persistence in a local database. Low computational load algorithms based on Euler angles and accelerometer, gyroscope and magnetometer signals were developed and used for the classification and identification of several gait disturbances. These algorithms include the alignment of IMUs sensors data by means of a common temporal reference as well as heel strike and stride detection algorithms to help segmentation of the remotely collected signals by the System app to identify gait strides and extract relevant features to feed, train and test a classifier to predict gait abnormalities in gait sessions. A set of drivers from Shimmer manufacturer is used to make the connection between the app and the set of IMUs using Bluetooth. The developed app allows users to collect data and train a classification model for identifying abnormal and normal gait types. The system provides a REST API available in a backend server along with Java and Python libraries and a PostgreSQL database. The machine-learning type is Supervised using Extremely Randomized Trees method. Frequency, time and time-frequency domain features were extracted from the collected and processed signals to train the classifier. To test the framework a set of gait abnormalities and normal gait were used to train a model and test the classifier.Este trabalho apresenta uma estrutura móvel acessível, simples e não intrusiva, que permite a monitorização e a assistência remota de pacientes durante a reabilitação da marcha, por médicos e fisioterapeutas que monitorizam a reabilitação da marcha do paciente. O sistema inclui um conjunto de 2 IMUs (Inertial Mesaurement Units) Shimmer3 da marca Shimmer, compatíveís com Bluetooth, um smartphone Android para recolha, e pré-processamento de dados e armazenamento numa base de dados local. Algoritmos de baixa carga computacional baseados em ângulos Euler e sinais de acelerómetros, giroscópios e magnetómetros foram desenvolvidos e utilizados para a classificação e identificação de diversas perturbações da marcha. Estes algoritmos incluem o alinhamento e sincronização dos dados dos sensores IMUs usando uma referência temporal comum, além de algoritmos de detecção de passos e strides para auxiliar a segmentação dos sinais recolhidos remotamente pelaappdestaframeworke identificar os passos da marcha extraindo as características relevantes para treinar e testar um classificador que faça a predição de deficiências na marcha durante as sessões de monitorização. Um conjunto de drivers do fabricante Shimmer é usado para fazer a conexão entre a app e o conjunto de IMUs através de Bluetooth. A app desenvolvida permite aos utilizadores recolher dados e treinar um modelo de classificação para identificar os tipos de marcha normais e patológicos. O sistema fornece uma REST API disponível num servidor backend recorrendo a bibliotecas Java e Python e a uma base de dados PostgreSQL. O tipo de machine-learning é Supervisionado usando Extremely Randomized Trees. Features no domínio do tempo, da frequência e do tempo-frequência foram extraídas dos sinais recolhidos e processados para treinar o classificador. Para testar a estrutura, um conjunto de marchas patológicas e normais foram utilizadas para treinar um modelo e testar o classificador

    Wearable Sensors Applied in Movement Analysis

    Get PDF
    Recent advances in electronics have led to sensors whose sizes and weights are such that they can be placed on living systems without impairing their natural motion and habits. They may be worn on the body as accessories or as part of the clothing and enable personalized mobile information processing. Wearable sensors open the way for a nonintrusive and continuous monitoring of body orientation, movements, and various physiological parameters during motor activities in real-life settings. Thus, they may become crucial tools not only for researchers, but also for clinicians, as they have the potential to improve diagnosis, better monitor disease development and thereby individualize treatment. Wearable sensors should obviously go unnoticed for the people wearing them and be intuitive in their installation. They should come with wireless connectivity and low-power consumption. Moreover, the electronics system should be self-calibrating and deliver correct information that is easy to interpret. Cross-platform interfaces that provide secure data storage and easy data analysis and visualization are needed.This book contains a selection of research papers presenting new results addressing the above challenges

    人のつま先制御能力を向上させる歩行訓練ロボットの適応的な介入手法の提案

    Get PDF
    早大学位記番号:新8439早稲田大

    Estimating fall risk with inertial sensors using gait stability measures that do not require step detection

    Get PDF
    Falls have major consequences both at societal (health-care and economy) and individual (physical and psychological) levels. Questionnaires to assess fall risk are commonly used in the clinic, but their predictive value is limited. Objective methods, suitable for clinical application, are hence needed to obtain a quantitative assessment of individual fall risk. Falls in older adults often occur during walking and trunk position is known to play a critical role in balance control. Therefore, analysis of trunk kinematics during gait could present a viable approach to the development of such methods. In this study, nonlinear measures such as harmonic ratio (HR), index of harmonicity (IH), multiscale entropy (MSE) and recurrence quantification analysis (RQA) of trunk accelerations were calculated. These measures are not dependent on step detection, a potentially critical source of error. The aim of the present study was to investigate the association between the aforementioned measures and fall history in a large sample of subjects (42 fallers and 89 non-fallers) aged 50 or older. Univariate associations with fall history were found for MSE and RQA parameters in the AP direction; the best classification results were obtained for MSE with scale factor τ = 2 and for maximum length of diagonals in RQA (72.5% and 71% correct classifications, respectively). MSE and RQA were found to be positively associated with fall history and could hence represent useful tools in the identification of subjects for fall prevention programs. © 2013 Elsevier B.V
    corecore