587 research outputs found

    Free-breathing Pulmonary MR Imaging to Quantify Regional Ventilation

    Get PDF
    Purpose: To measure regional specific ventilation with free-breathing hydrogen 1 (1H) magnetic resonance (MR) imaging without exogenous contrast material and to investigate correlations with hyperpolarized helium 3 (3He) MR imaging and pulmonary function test measurements in healthy volunteers and patients with asthma. Materials and Methods: Subjects underwent free-breathing 1H and static breath-hold hyperpolarized 3He MR imaging as well as spirometry and plethysmography; participants were consecutively recruited between January and June 2017. Free-breathing 1H MR imaging was performed with an optimized balanced steady-state free-precession sequence; images were retrospectively grouped into tidal inspiration or tidal expiration volumes with exponentially weighted phase interpolation. MR imaging volumes were coregistered by using optical flow deformable registration to generate 1H MR imaging-derived specific ventilation maps. Hyperpolarized 3He MR imaging- and 1H MR imaging-derived specific ventilation maps were coregistered to quantify regional specific ventilation within hyperpolarized 3He MR imaging ventilation masks. Differences between groups were determined with the Mann-Whitney test and relationships were determined with Spearman (ρ) correlation coefficients. Statistical analyses were performed with software. Results: Thirty subjects (median age: 50 years; interquartile range [IQR]: 30 years), including 23 with asthma and seven healthy volunteers, were evaluated. Both 1H MR imaging-derived specific ventilation and hyperpolarized 3He MR imaging-derived ventilation percentage were significantly greater in healthy volunteers than in patients with asthma (specific ventilation: 0.14 [IQR: 0.05] vs 0.08 [IQR: 0.06], respectively, P \u3c .0001; ventilation percentage: 99% [IQR: 1%] vs 94% [IQR: 5%], P \u3c .0001). For all subjects, 1H MR imaging-derived specific ventilation correlated with plethysmography-derived specific ventilation (ρ = 0.54, P = .002) and hyperpolarized 3He MR imaging-derived ventilation percentage (ρ = 0.67, P \u3c .0001) as well as with forced expiratory volume in 1 second (FEV1) (ρ = 0.65, P = .0001), ratio of FEV1 to forced vital capacity (ρ = 0.75, P \u3c .0001), ratio of residual volume to total lung capacity (ρ = -0.68, P \u3c .0001), and airway resistance (ρ = -0.51, P = .004). 1H MR imaging-derived specific ventilation was significantly greater in the gravitational-dependent versus nondependent lung in healthy subjects (P = .02) but not in patients with asthma (P = .1). In patients with asthma, coregistered 1H MR imaging specific ventilation and hyperpolarized 3He MR imaging maps showed that specific ventilation was diminished in corresponding 3He MR imaging ventilation defects (0.05 ± 0.04) compared with well-ventilated regions (0.09 ± 0.05) (P \u3c .0001). Conclusion: 1H MR imaging-derived specific ventilation correlated with plethysmography-derived specific ventilation and ventilation defects seen by using hyperpolarized 3He MR imaging. © RSNA, 2018 Online supplemental material is available for this article

    Comparison of Image Registration Based Measures of Regional Lung Ventilation from Dynamic Spiral CT with Xe-CT

    Full text link
    Purpose: Regional lung volume change as a function of lung inflation serves as an index of parenchymal and airway status as well as an index of regional ventilation and can be used to detect pathologic changes over time. In this article, we propose a new regional measure of lung mechanics --- the specific air volume change by corrected Jacobian. Methods: 4DCT and Xe-CT data sets from four adult sheep are used in this study. Nonlinear, 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration. Approximately 200 annotated anatomical points are used as landmarks to evaluate registration accuracy. Three different registration-based measures of regional lung mechanics are derived and compared: the specific air volume change calculated from the Jacobian (SAJ); the specific air volume change calculated by the corrected Jacobian (SACJ); and the specific air volume change by intensity change (SAI). Results: After registration, the mean registration error is on the order of 1 mm. For cubical ROIs in cubes with size 20 mm ×\times 20 mm ×\times 20 mm, the SAJ and SACJ measures show significantly higher correlation (linear regression, average r2=0.75r^2=0.75 and r2=0.82r^2=0.82) with the Xe-CT based measure of specific ventilation (sV) than the SAI measure. For ROIs in slabs along the ventral-dorsal vertical direction with size of 150 mm ×\times 8 mm ×\times 40 mm, the SAJ, SACJ, and SAI all show high correlation (linear regression, average r2=0.88r^2=0.88, r2=0.92r^2=0.92 and r2=0.87r^2=0.87) with the Xe-CT based sV without significant differences when comparing between the three methods. Conclusion: Given a deformation field by an image registration algorithm, significant differences between the SAJ, SACJ, and SAI measures were found at a regional level compared to the Xe-CT sV in four sheep that were studied

    Emissions by aerial routes from protected crop systems (greenhouses and crops grown under cover) : a position paper

    Get PDF
    This report describes the processes that may lead to emission of Plant Protection Products (PPP) from protected cultivation, through aerial routes. The introduction gives the background for this work and the limitations, outlining in particular why receptors other than air are not explicitly addressed here. Chapters 2 discusses the physical background of greenhouse air exchanges and the factors that affect it. Existing models for estimating ventilation of the different types of greenhouses are reviewed there. Chapter 3 gives a scientific argument about the processes and the factors that may affect aerial emissions of PPP from protected cultivations. The parameters that may have an high impact on the emission are identified there as well. A review of the knowledge needed and of the models that may be available for scoring each emission route is given in Chapter 4. In Chapter 5 a strategy is proposed to reduce/group the number of factors that are important (and to score their relevance) through some model calculations. An outline of the calculations that would be needed for ranking and eventually scoring the emissions and, possibly, highlight groupings of combinations that are similar with respect to emissions, is given

    Assessment of alternative power sources for mobile mining machinery

    Get PDF
    Alternative mobile power sources for mining applications were assessed. A wide variety of heat engines and energy systems was examined as potential alternatives to presently used power systems. The present mobile power systems are electrical trailing cable, electrical battery, and diesel - with diesel being largely limited in the United States to noncoal mines. Each candidate power source was evaluated for the following requirements: (1) ability to achieve the duty cycle; (2) ability to meet Government regulations; (3) availability (production readiness); (4) market availability; and (5) packaging capability. Screening reduced the list of candidates to the following power sources: diesel, stirling, gas turbine, rankine (steam), advanced electric (batteries), mechanical energy storage (flywheel), and use of hydrogen evolved from metal hydrides. This list of candidates is divided into two classes of alternative power sources for mining applications, heat engines and energy storage systems

    Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Get PDF
    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency

    Ventilation–perfusion heterogeneity measured by the multiple inert gas elimination technique is minimally affected by intermittent breathing of 100% O2

    Get PDF
    Proton magnetic resonance (MR) imaging to quantify regional ventilation–perfusion ((Formula presented.)) ratios combines specific ventilation imaging (SVI) and separate proton density and perfusion measures into a composite map. Specific ventilation imaging exploits the paramagnetic properties of O2, which alters the local MR signal intensity, in an FIO2-dependent manner. Specific ventilation imaging data are acquired during five wash-in/wash-out cycles of breathing 21% O2 alternating with 100% O2 over ~20 min. This technique assumes that alternating FIO2 does not affect (Formula presented.) heterogeneity, but this is unproven. We tested the hypothesis that alternating FIO2 exposure increases (Formula presented.) mismatch in nine patients with abnormal pulmonary gas exchange and increased (Formula presented.) mismatch using the multiple inert gas elimination technique (MIGET).The following data were acquired (a) breathing air (baseline), (b) breathing alternating air/100% O2 during an emulated-SVI protocol (eSVI), and (c) 20 min after ambient air breathing (recovery). MIGET heterogeneity indices of shunt, deadspace, ventilation versus (Formula presented.) ratio, LogSD (Formula presented.), and perfusion versus (Formula presented.) ratio, LogSD (Formula presented.) were calculated. LogSD (Formula presented.) was not different between eSVI and baseline (1.04 ± 0.39 baseline, 1.05 ± 0.38 eSVI, p =.84); but was reduced compared to baseline during recovery (0.97 ± 0.39, p =.04). There was no significant difference in LogSD (Formula presented.) across conditions (0.81 ± 0.30 baseline, 0.79 ± 0.15 eSVI, 0.79 ± 0.20 recovery; p =.54); Deadspace was not significantly different (p =.54) but shunt showed a borderline increase during eSVI (1.0% ± 1.0 baseline, 2.6% ± 2.9 eSVI; p =.052) likely from altered hypoxic pulmonary vasoconstriction and/or absorption atelectasis. Intermittent breathing of 100% O2 does not substantially alter (Formula presented.) matching and if SVI measurements are made after perfusion measurements, any potential effects will be minimized

    Numerical and Experimental Study of Fan and Pad Evaporative Cooling System in a Greenhouse with Tomato Crop

    Get PDF
    An experimental greenhouse equipped with fan and pad evaporative cooling is simulated numerically using a commercial CFD code. The main aspects of evaporative cooling systems, in terms of heat and mass transfer and both the external and internal climatic conditions were integrated to set up the numerical model. The crop (tomato) was simulated using the equivalent porous medium approach by the addition of a momentum and energy source term. Preliminary calculations were carried out and validated by experimental measurements, in order the pressure drop occurred in crop model due to air flow, to be determined as a function of leaf area, stage of crop growth and cultivation technique. The temperature and humidity of incoming air and the operational characteristics of exhaust fans were specified to set up the CFD model. The numerical analysis was based on the Reynolds-averaged Navier-Stokes equations in conjunction with the RNG k- turbulence model. The finite-volume method (FVM) was used to solve the governing equations. The 3D full scale model was solved in several differencing schemes of various orders in order to examine its accuracy. The simulation results were validated with experimental measurements obtained at a height level of 1.2 m above the ground in the middle of the crop canopy at 23 and 8 points, concerning air temperature and air humidity respectively. The correlation coefficient between computational results and experimental data was at the order of 0.7419 for air temperature and 0.8082 for air relative humidity. The results showing that the evaporative cooling system for greenhouses could be effectively parameterized in numerical terms, providing a useful tool in order to improve system’s efficiency

    Scoping study on the significance of mesh resolution vs. scenario uncertainty in the CFD modelling of residential smoke control systems

    Get PDF
    Computational fluid dynamics (CFD) modelling is a commonly applied tool adopted to support the specification and design of common corridor ventilation systems in UK residential buildings. Inputs for the CFD modelling of common corridor ventilation systems are typically premised on a ‘reasonable worst case’, i.e. no specific uncertainty quantification process is undertaken to evaluate the safety level. As such, where the performance of a specific design sits on a probability spectrum is not defined. Furthermore, mesh cell sizes adopted are typically c. 100 – 200 mm. For a large eddy simulation (LES) based CFD code, this is considered coarse for this application and creates a further uncertainty in respect of capturing key behaviours in the CFD model. Both co-existing practices summarised above create uncertainty, either due to parameter choice or the (computational fire and smoke) model. What is not clear is the relative importance of these uncertainties. This paper summarises a scoping study that subjects the noted common corridor CFD application to a probabilistic risk assessment (PRA), using the MaxEnt method. The uncertainty associated with the performance of a reference design is considered at different grid scales (achieving different ‘a posteriori’ mesh quality indicators), with the aim of quantifying the relative importance of uncertainties associated with inputs and scenarios, vs. the fidelity of the CFD model. For the specific case considered herein, it is found that parameter uncertainty has a more significant impact on the confidence of a given design solution relative to that arising from grid resolution, for grid sizes of 100 mm or less. Above this grid resolution, it was found that uncertainty associated with the model dictates. Given the specific ventilation arrangement modelled in this work care should be undertaken in generalising such conclusions

    Aerospace Medicine and Biology: A continuing bibliography with indexes, supplement 182, July 1978

    Get PDF
    This bibliography lists 165 reports, articles, and other documents introduced into the NASA scientific and technical information system in June 1978
    corecore