1,327 research outputs found
Radiopurity of Micromegas readout planes
Micromesh Gas Amplification Structures (Micromegas) are being used in an
increasing number of Particle Physics applications since their conception
fourteen years ago. More recently, they are being used or considered as readout
of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing
with dark matter, axions or double beta decay). In these experiments, the
radiopurity of the detector components and surrounding materials is measured
and finely controlled in order to keep the experimental background as low as
possible. In the present paper, the first measurement of the radiopurity of
Micromegas planes obtained by high purity germanium spectrometry in the low
background facilities of the Canfranc Underground Laboratory (LSC) is
presented. The obtained results prove that Micromegas readouts of the microbulk
type are currently manufactured with radiopurity levels below 30 microBq/cm2
for Th and U chains and ~60 microBq/cm2 for 40K, already comparable to the
cleanest detector components of the most stringent low background experiments
at present. Taking into account that the studied readouts were manufactured
without any specific control of the radiopurity, it should be possible to
improve these levels after dedicated development.Comment: 15 pages, 2 figure
Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection
Over the course of several decades, organic liquid scintillators have formed
the basis for successful neutrino detectors. Gadolinium-loaded liquid
scintillators provide efficient background suppression for electron
antineutrino detection at nuclear reactor plants. In the Double Chooz reactor
antineutrino experiment, a newly developed beta-diketonate gadolinium-loaded
scintillator is utilized for the first time. Its large scale production and
characterization are described. A new, light yield matched metal-free companion
scintillator is presented. Both organic liquids comprise the target and "Gamma
Catcher" of the Double Chooz detectors.Comment: 16 pages, 4 figures, 5 table
Borexino: A real time liquid scintillator detector for low energy solar neutrino study
Borexino is a large unsegmented calorimeter featuring 300 tons of liquid
scintillator, contained in a 8.5 meter nylon vessel, viewed by 2200 PMTs. The
main goal of Borexino is the study, in real time, of low energy solar
neutrinos, and in particular, the monoenergetic neutrinos coming from ,
which is one of the missing links on the solar neutrino problem. The
achievement of high radiopurity level, in the order of of U/Th
equivalent, necessary to the detection of the low energy component of the solar
neutrino flux, was proved in the Borexino prototype: the Counting Test
Facility. The detector is located underground in the Laboratori Nazionali del
Gran Sasso in the center of Italy at 3500 meter water equivalent depth. In this
paper the science and technology of Borexino are reviewed and its main
capabilities are presented.Comment: 8 pages, 3 figures, 10th International Conference on Calorimetry in
High Energy Physics. http://3w.hep.caltech.edu/calor02
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils
The development of BiPo detectors is dedicated to the measurement of
extremely high radiopurity in Tl and Bi for the SuperNEMO
double beta decay source foils. A modular prototype, called BiPo-1, with 0.8
of sensitive surface area, has been running in the Modane Underground
Laboratory since February, 2008. The goal of BiPo-1 is to measure the different
components of the background and in particular the surface radiopurity of the
plastic scintillators that make up the detector. The first phase of data
collection has been dedicated to the measurement of the radiopurity in
Tl. After more than one year of background measurement, a surface
activity of the scintillators of (Tl) 1.5
Bq/m is reported here. Given this level of background, a larger BiPo
detector having 12 m of active surface area, is able to qualify the
radiopurity of the SuperNEMO selenium double beta decay foils with the required
sensitivity of (Tl) 2 Bq/kg (90% C.L.) with a six
month measurement.Comment: 24 pages, submitted to N.I.M.
Measurement of the Intrinsic Radiopurity of Cs-137/U-235/U-238/Th-232 in CsI(Tl) Crystal Scintillators
The inorganic crystal scintillator CsI(Tl) has been used for low energy
neutrino and Dark Matter experiments, where the intrinsic radiopurity is an
issue of major importance. Low-background data were taken with a CsI(Tl)
crystal array at the Kuo-Sheng Reactor Neutrino Laboratory. The pulse shape
discrimination capabilities of the crystal, as well as the temporal and spatial
correlations of the events, provide powerful means of measuring the intrinsic
radiopurity of Cs-137 as well as the U-235, U-238 and Th-232 series. The event
selection algorithms are described, with which the decay half-lives of Po-218,
Po-214, Rn-220, Po-216 and Po-212 were derived. The measurements of the
contamination levels, their concentration gradients with the crystal growth
axis, and the uniformity among different crystal samples, are reported. The
radiopurity in the U-238 and Th-232 series are comparable to those of the best
reported in other crystal scintillators. Significant improvements in
measurement sensitivities were achieved, similar to those from dedicated
massive liquid scintillator detector. This analysis also provides in situ
measurements of the detector performance parameters, such as spatial
resolution, quenching factors, and data acquisition dead time.Comment: 28 pages, 12 figure
The 4 K outer cryostat for the CUORE experiment: construction and quality control
The external shell of the CUORE cryostat is a large cryogen-free system
designed to host the dilution refrigerator and the bolometers of the CUORE
experiment in a low radioactivity environment. The three vessels that form the
outer shell were produced and delivered to the Gran Sasso underground
Laboratories in July 2012. In this paper, we describe the production techniques
and the validation tests done at the production site in 2012.Comment: 11 pages, 13 figures; to appear in NIM
Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection
Over the course of several decades, organic liquid scintillators have formed
the basis for successful neutrino detectors. Gadolinium-loaded liquid
scintillators provide efficient background suppression for electron
antineutrino detection at nuclear reactor plants. In the Double Chooz reactor
antineutrino experiment, a newly developed beta-diketonate gadolinium-loaded
scintillator is utilized for the first time. Its large scale production and
characterization are described. A new, light yield matched metal-free companion
scintillator is presented. Both organic liquids comprise the target and "Gamma
Catcher" of the Double Chooz detectors.Comment: 16 pages, 4 figures, 5 table
Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection
Over the course of several decades, organic liquid scintillators have formed
the basis for successful neutrino detectors. Gadolinium-loaded liquid
scintillators provide efficient background suppression for electron
antineutrino detection at nuclear reactor plants. In the Double Chooz reactor
antineutrino experiment, a newly developed beta-diketonate gadolinium-loaded
scintillator is utilized for the first time. Its large scale production and
characterization are described. A new, light yield matched metal-free companion
scintillator is presented. Both organic liquids comprise the target and "Gamma
Catcher" of the Double Chooz detectors.Comment: 16 pages, 4 figures, 5 table
- …