12 research outputs found

    Non-Contact Detection of Vital Signs Based on Improved Adaptive EEMD Algorithm (July 2022)

    Get PDF
    Non-contact vital sign detection technology has brought a more comfortable experience to the detection process of human respiratory and heartbeat signals. Ensemble empirical mode decomposition (EEMD) is a noise-assisted adaptive data analysis method which can be used to decompose the echo data of frequency modulated continuous wave (FMCW) radar and extract the heartbeat and respiratory signals. The key of EEMD is to add Gaussian white noise into the signal to overcome the mode aliasing problem caused by original empirical mode decomposition (EMD). Based on the characteristics of clutter and noise distribution in public places, this paper proposed a static clutter filtering method for eliminating ambient clutter and an improved EEMD method based on stable alpha noise distribution. The symmetrical alpha stable distribution is used to replace Gaussian distribution, and the improved EEMD is used for the separation of respiratory and heartbeat signals. The experimental results show that the static clutter filtering technology can effectively filter the surrounding static clutter and highlight the periodic moving targets. Within the detection range of 0.5 m similar to 2.5 m, the improved EEMD method can better distinguish the heartbeat, respiration, and their harmonics, and accurately estimate the heart rate

    Noncontact Vital Signs Detection

    Get PDF
    Human health condition can be accessed by measurement of vital signs, i.e., respiratory rate (RR), heart rate (HR), blood oxygen level, temperature and blood pressure. Due to drawbacks of contact sensors in measurement, non-contact sensors such as imaging photoplethysmogram (IPPG) and Doppler radar system have been proposed for cardiorespiratory rates detection by researchers.The UWB pulse Doppler radars provide high resolution range-time-frequency information. It is bestowed with advantages of low transmitted power, through-wall capabilities, and high resolution in localization. However, the poor signal to noise ratio (SNR) makes it challenging for UWB radar systems to accurately detect the heartbeat of a subject. To solve the problem, phased-methods have been proposed to extract the phase variations in the reflected pulses modulated by human tiny thorax motions. Advance signal processing method, i.e., state space method, can not only be used to enhance SNR of human vital signs detection, but also enable the micro-Doppler trajectories extraction of walking subject from UWB radar data.Stepped Frequency Continuous Wave (SFCW) radar is an alternative technique useful to remotely monitor human subject activities. Compared with UWB pulse radar, it relieves the stress on requirement of high sampling rate analog-to-digital converter (ADC) and possesses higher signal-to-noise-ratio (SNR) in vital signs detection. However, conventional SFCW radar suffers from long data acquisition time to step over many frequencies. To solve this problem, multi-channel SFCW radar has been proposed to step through different frequency bandwidths simultaneously. Compressed sensing (CS) can further reduce the data acquisition time by randomly stepping through 20% of the original frequency steps.In this work, SFCW system is implemented with low cost, off-the-shelf surface mount components to make the radar sensors portable. Experimental results collected from both pulse and SFCW radar systems have been validated with commercial contact sensors and satisfactory results are shown

    Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary

    Get PDF
    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k-th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences

    Signal Processing Contributions to Contactless Monitoring of Vital Signs Using Radars

    Get PDF
    Vital signs are a group of biological indicators that show the status of the body’s life-sustaining functions. They provide an objective measurement of the essential physiological functions of a living organism, and their assessment is the critical first step for any clinical evaluation. Monitoring vital sign information provides valuable insight into the patient's condition, including how they are responding to medical treatment and, more importantly, whether the patient is deteriorating. However, conventional contact-based devices are inappropriate for long-term continuous monitoring. Besides mobility restrictions and stress, they can cause discomfort, and epidermal damage, and even lead to pressure necrosis. On the other hand, the contactless monitoring of vital signs using radar devices has several advantages. Radar signals can penetrate through different materials and are not affected by skin pigmentation or external light conditions. Additionally, these devices preserve privacy, can be low-cost, and transmit no more power than a mobile phone. Despite recent advances, accurate contactless vital sign monitoring is still challenging in practical scenarios. The challenge stems from the fact that when we breathe, or when the heart beats, the tiny induced motion of the chest wall surface can be smaller than one millimeter. This means that the vital sign information can be easily lost in the background noise, or even masked by additional body movements from the monitored subject. This thesis aims to propose innovative signal processing solutions to enable the contactless monitoring of vital signs in practical scenarios. Its main contributions are threefold: a new algorithm for recovering the chest wall movements from radar signals; a novel random body movement and interference mitigation technique; and a simple, yet robust and accurate, adaptive estimation framework. These contributions were tested under different operational conditions and scenarios, spanning ideal simulation settings, real data collected while imitating common working conditions in an office environment, and a complete validation with premature babies in a critical care environment. The proposed algorithms were able to precisely recover the chest wall motion, effectively reducing the interfering effects of random body movements, and allowing clear identification of different breathing patterns. This capability is the first step toward frequency estimation and early non-invasive diagnosis of cardiorespiratory problems. In addition, most of the time, the adaptive estimation framework provided breathing and heart rate estimates within the predefined error intervals, being capable of tracking the reference values in different scenarios. Our findings shed light on the strengths and limitations of this technology and lay the foundation for future studies toward a complete contactless solution for vital signs monitoring

    Methods for Doppler Radar Monitoring of Physiological Signals

    Get PDF
    Unobtrusive health monitoring includes advantages such as long-term monitoring of rarely occurring conditions or of slow changes in health, at reasonable costs. In addition, the preparation of electrodes or other sensors is not needed. Currently, the main limitation of remote patient monitoring is not in the existing communication infrastructure but the lack of reliable, easy-to-use, and well-studied sensors.The aim of this thesis was to develop methods for monitoring cardiac and respiratory activity with microwave continuous wave (CW) Doppler radar. When considering cardiac and respiration monitoring, the heart and respiration rates are often the first monitored parameters. The motivation of this thesis, however, is to measure not only rate-related parameters but also the cardiac and respiratory waveforms, including the chest wall displacement information.This dissertation thoroughly explores the signal processing methods for accurate chest wall displacement measurement with a radar sensor. The sensor prototype and measurement setup choices are reported. The contributions of this dissertation encompass an I/Q imbalance estimation method and a nonlinear demodulation method for a quadrature radar sensor. Unlike the previous imbalance estimation methods, the proposed method does not require the use of laboratory equipment. The proposed nonlinear demodulation method, on the other hand, is shown to be more accurate than other methods in low-noise cases. In addition, the separation of the cardiac and respiratory components with independent component analysis (ICA) is discussed. The developed methods were validated with simulations and with simplified measurement setups in an office environment. The performance of the nonlinear demodulation method was also studied with three patients for sleep-time respiration monitoring. This is the first time that whole-night measurements have been analyzed with the method in an uncontrolled environment. Data synchronization between the radar sensor and a commercial polysomnographic (PSG) device was assured with a developed infrared (IR) link, which is reported as a side result.The developed methods enable the extraction of more useful information from a radar sensor and extend its application. This brings Doppler radar sensors one step closer to large-scale commercial use for a wide range of applications, including home health monitoring, sleep-time respiration monitoring, and measuring gating signals for medical imaging

    Remote vital signs monitoring using a mm-wave FMCW radar

    Get PDF
    A vision on the migration from contact standard health monitoring measurement devices to non-contact measurement technologies has gained a tremendous attention in literature and in industry. A promising method for realizing the remote measurement of vital signs is using electromagnetic radars such as frequency modulated continuous wave (FMCW) radars. However, using these radars has challenges to precisely acquire the respiration and heart rates. A solution for higher accurate measurement of the vital signs can be the use of mm-wave frequencies, which gives a high-resolution sensing of displacements in an environment in the order of sub-mm changes. On the other hand, being in mm-wave bands increases both hardware and signal processing designs and implementations. In this work, a mm-wave radar is used to monitor the breathing and the heart rates as well as their waveforms for further clinical diagnostics. To that end, we established a complete analysis of the FMCW radars principles by considering hardware impairments. The analysis considers the effect of antenna coupling, RF cross-talk, stationary clutters, phase noise, IQ imbalances, and the thermal noise. Also, the effect of the individual hardware imperfections on the phase quality is shown by simulations and experiments. The simulations are carried out with a Matlab Simulink model. For the experiments, Texas Instruments (TI) mm-wave FMCW radars have been used. To earn insight into vital signs monitoring, different experiments are designed. In the experiments, the effect of the thermal instability of the RF parts on the phase is shown. In addition, to mimic the behaviour of the chest vibration due to respiration and the heartbeats, a two-pendulum system is designed and tested. Particularly, the pendulum system performance in terms of vibration frequency estimations of the two pendulums versus distance is then measured. In the simulations, the system performance is obtained for different signal to noise ratios (SNR) and different phase noise levels, as well as different stationary clutters. Finally, to test the TI sensors for different directions to the subjects, Hexoskin smart garment is used as a reference sensor, which is a reliable commercial product. Our results show great system improvement in terms of accuracy of the vital signs detection in comparison to other similar research. For different sleep positions, the accuracy of HR and BR are greater than 94\% and 96\%, respectively. In addition to detecting the vital rates, we have shown that their waveforms can also be reconstructed by using an adaptive optimum filter

    Sensors for Vital Signs Monitoring

    Get PDF
    Sensor technology for monitoring vital signs is an important topic for various service applications, such as entertainment and personalization platforms and Internet of Things (IoT) systems, as well as traditional medical purposes, such as disease indication judgments and predictions. Vital signs for monitoring include respiration and heart rates, body temperature, blood pressure, oxygen saturation, electrocardiogram, blood glucose concentration, brain waves, etc. Gait and walking length can also be regarded as vital signs because they can indirectly indicate human activity and status. Sensing technologies include contact sensors such as electrocardiogram (ECG), electroencephalogram (EEG), photoplethysmogram (PPG), non-contact sensors such as ballistocardiography (BCG), and invasive/non-invasive sensors for diagnoses of variations in blood characteristics or body fluids. Radar, vision, and infrared sensors can also be useful technologies for detecting vital signs from the movement of humans or organs. Signal processing, extraction, and analysis techniques are important in industrial applications along with hardware implementation techniques. Battery management and wireless power transmission technologies, the design and optimization of low-power circuits, and systems for continuous monitoring and data collection/transmission should also be considered with sensor technologies. In addition, machine-learning-based diagnostic technology can be used for extracting meaningful information from continuous monitoring data

    AI enabled RF sensing of Diversified Human-Centric Monitoring

    Get PDF
    This thesis delves into the application of various RF signaling techniques in HumanCentric Monitoring (HCM), specifically focusing on WiFi, LoRa, Ultra-wideband (UWB) radars, and Frequency Modulated Continuous Wave (FMCW) radars. Each of these technologies has unique properties suitable for different aspects of HCM. For instance, 77GHz FMCW radar signals demonstrate high sensitivity in detecting subtle human movements, such as heartbeat, contrasting with the capabilities of 2.4GHz/5GHz WiFi signals. The research extends to both large-scale and small-scale Human Activity Recognition (HAR), examining how ubiquitous communication signals like WiFi and LoRa can be utilized for large-scale HAR, while radar signals with higher central frequencies are more effective for small-scale motions, including heartbeat and mouth movements. The thesis also identifies several unresolved challenges in the field. These include the underutilization of spatial spectral information in existing WiFi sensing technologies, the untapped potential of LoRa technology in identity recognition, the sensitivity of millimeterwave radar in detecting breathing and heartbeat against minor movements, and the lack of comprehensive datasets for mouth motion detection in silent speech recognition. Addressing these challenges, the paper proposes several innovative solutions: • A comprehensive analysis of methodologies for RF-based HCM applications, discussing challenges and proposing potential solutions for broader healthcare applications using wireless sensing. • Exploration of communication signals in HCM systems, especially focusing on WiFi and LoRa sensing. It introduces the continuous AoA-ToF maps method to enhance HCM system performance and the LoGait system, which uses LoRa signals for human gait identification, extending the sensing range to 20 meters. • Development of a FMCW radar-based structure for respiration detection, incorporating an ellipse normalization method to adjust distorted IQ signals, reducing the root mean square error by 30% compared to baseline methods. • Collection and analysis of a large-scale multimodal dataset for silent speech recognition and speech enhancement, including designing experiments to validate the dataset’s utility in a multimodal-based speech recognition system
    corecore