387 research outputs found

    Identification of cardiac signals in ambulatory ECG data

    Get PDF
    The Electrocardiogram (ECG) is the primary tool for monitoring heart function. ECG signals contain vital information about the heart which informs diagnosis and treatment of cardiac conditions. The diagnosis of many cardiac arrhythmias require long term and continuous ECG data, often while the participant engages in activity. Wearable ambulatory ECG (AECG) systems, such as the common Holter system, allow heart monitoring for hours or days. The technological trajectory of AECG systems aims towards continuous monitoring during a wide range of activities with data processed locally in real time and transmitted to a monitoring centre for further analysis. Furthermore, hierarchical decision systems will allow wearable systems to produce alerts or even interventions. These functions could be integrated into smartphones.A fundamental limitation of this technology is the ability to identify heart signal characteristics in ECG signals contaminated with high amplitude and non-stationary noise. Noise processing become more severe as activity levels increase, and this is also when many heart problems are present.This thesis focuses on the identification of heart signals in AECG data recorded during participant activity. In particular, it explored ECG filters to identify major heart conditions in noisy AECG data. Gold standard methods use Extended Kalman filters with extrapolation based on sum of Gaussian models. New methods are developed using linear Kalman filtering and extrapolation based on a sum of Principal Component basis signals. Unlike the gold standard methods, extrapolation is heartcycle by heartcycle. Several variants are explored where basic signals span one or two heartcycles, and applied to single or multi-channel ECG data.The proposed methods are extensively tested against standard databases or normal and abnormal ECG data and the performance is compared to gold standard methods. Two performance metrics are used: improvement in signal to noise ratio and the observability of clinically important features in the heart signal. In all tests the proposed method performs better, and often significantly better, than the gold standard methods. It is demonstrated that abnormal ECG signals can be identified in noisy AECG data

    Microwire regenerative peripheral nerve interfaces with wireless recording and stimulation capabilities

    Get PDF
    A scalable microwire peripheral nerve interface was developed, which interacted with regenerated peripheral nerves in microchannel scaffolds. Neural interface technologies are envisioned to facilitate direct connections between the nervous system and external technologies such as limb prosthetics or data acquisition systems for further processing. Presented here is an animal study using a handcrafted microwire regenerative peripheral nerve interface, a novel neural interface device for communicating with peripheral nerves. The neural interface studies using animal models are crucial in the evaluation of efficacy and safety of implantable medical devices before their use in clinical studies.16-electrode microwire microchannel scaffolds were developed for both peripheral nerve regeneration and peripheral nerve interfacing. The microchannels were used for nerve regeneration pathways as a scaffolding material and the embedded microwires were used as a recording electrode to capture neural signals from the regenerated peripheral nerves. Wireless stimulation and recording capabilities were also incorporated to the developed peripheral nerve interface which gave the freedom of the complex experimental setting of wired data acquisition systems and minimized the potential infection of the animals from the wire connections

    Artificial Intelligence for Noninvasive Fetal Electrocardiogram Analysis

    Get PDF

    Spike detection and clustering with unsupervised wavelet optimization in extracellular neural recordings

    Get PDF

    On the use of wavelet denoising and spike sorting techniques to process electroneurographic signals recorded using intraneural electrodes.

    Get PDF
    Among the possible interfaces with the peripheral nervous system (PNS), intraneural electrodes represent an interesting solution for their potential advantages such as the possibility of extracting spikes from electroneurographic (ENG) signals. Their use could increase the precision and the amount of information which can be detected with respect to other processing methods. In this study, in order to verify this assumption, thin-film longitudinal intrafascicular electrodes (tfLIFE) were implanted in the sciatic nerve of rabbits. Various sensory stimuli were applied to the hind limb of the animal and the elicited ENG signals were recorded using the tfLIFEs. These signals were processed to determine whether the different types of information can be decoded. Signals were wavelet denoised and spike sorted. Support vector machines were trained to use the spike waveforms found to infer the stimulus applied to the rabbit. This approach was also compared with previously used ENG-processing methods. The results indicate that the combination of wavelet denoising and spike sorting techniques can increase the amount of information extractable from ENG signals recorded with intraneural electrodes. This strategy could allow the development of more effective closed-loop neuroprostheses and hybrid bionic systems connecting the human nervous system with artificial devices

    Noise Reduction of EEG Signals Using Autoencoders Built Upon GRU based RNN Layers

    Get PDF
    Understanding the cognitive and functional behaviour of the brain by its electrical activity is an important area of research. Electroencephalography (EEG) is a method that measures and record electrical activities of the brain from the scalp. It has been used for pathology analysis, emotion recognition, clinical and cognitive research, diagnosing various neurological and psychiatric disorders and for other applications. Since the EEG signals are sensitive to activities other than the brain ones, such as eye blinking, eye movement, head movement, etc., it is not possible to record EEG signals without any noise. Thus, it is very important to use an efficient noise reduction technique to get more accurate recordings. Numerous traditional techniques such as Principal Component Analysis (PCA), Independent Component Analysis (ICA), wavelet transformations and machine learning techniques were proposed for reducing the noise in EEG signals. The aim of this paper is to investigate the effectiveness of stacked autoencoders built upon Gated Recurrent Unit (GRU) based Recurrent Neural Network (RNN) layers (GRU-AE) against PCA. To achieve this, Harrell-Davis decile values for the reconstructed signals’ signal-to- noise ratio distributions were compared and it was found that the GRU-AE outperformed PCA for noise reduction of EEG signals

    Tutorial: A guide to techniques for analysing recordings from the peripheral nervous system

    Get PDF
    The nervous system, through a combination of conscious and automatic processes, enables the regulation of the body and its interactions with the environment. The peripheral nervous system is an excellent target for technologies that seek to modulate, restore or enhance these abilities as it carries sensory and motor information that most directly relates to a target organ or function. However, many applications require a combination of both an effective peripheral nerve interface and effective signal processing techniques to provide selective and stable recordings. While there are many reviews on the design of peripheral nerve interfaces, reviews of data analysis techniques and translational considerations are limited. Thus, this tutorial aims to support new and existing researchers in the understanding of the general guiding principles, and introduces a taxonomy for electrode configurations, techniques and translational models to consider
    • …
    corecore