195 research outputs found

    Intraoperative tissue classification methods in orthopedic and neurological surgeries: A systematic review

    Full text link
    Accurate tissue differentiation during orthopedic and neurological surgeries is critical, given that such surgeries involve operations on or in the vicinity of vital neurovascular structures and erroneous surgical maneuvers can lead to surgical complications. By now, the number of emerging technologies tackling the problem of intraoperative tissue classification methods is increasing. Therefore, this systematic review paper intends to give a general overview of existing technologies. The review was done based on the PRISMA principle and two databases: PubMed and IEEE Xplore. The screening process resulted in 60 full-text papers. The general characteristics of the methodology from extracted papers included data processing pipeline, machine learning methods if applicable, types of tissues that can be identified with them, phantom used to conduct the experiment, and evaluation results. This paper can be useful in identifying the problems in the current status of the state-of-the-art intraoperative tissue classification methods and designing new enhanced techniques

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    Image-guided surgery and medical robotics in the cranial area

    Get PDF
    Surgery in the cranial area includes complex anatomic situations with high-risk structures and high demands for functional and aesthetic results. Conventional surgery requires that the surgeon transfers complex anatomic and surgical planning information, using spatial sense and experience. The surgical procedure depends entirely on the manual skills of the operator. The development of image-guided surgery provides new revolutionary opportunities by integrating presurgical 3D imaging and intraoperative manipulation. Augmented reality, mechatronic surgical tools, and medical robotics may continue to progress in surgical instrumentation, and ultimately, surgical care. The aim of this article is to review and discuss state-of-the-art surgical navigation and medical robotics, image-to-patient registration, aspects of accuracy, and clinical applications for surgery in the cranial area

    Developing a virtual reality environment for petrous bone surgery: a state-of-the-art review

    Get PDF
    The increasing power of computers has led to the development of sophisticated systems that aim to immerse the user in a virtual environment. The benefits of this type of approach to the training of physicians and surgeons are immediately apparent. Unfortunately the implementation of “virtual reality” (VR) surgical simulators has been restricted by both cost and technical limitations. The few successful systems use standardized scenarios, often derived from typical clinical data, to allow the rehearsal of procedures. In reality we would choose a system that allows us not only to practice typical cases but also to enter our own patient data and use it to define the virtual environment. In effect we want to re-write the scenario every time we use the environment and to ensure that its behavior exactly duplicates the behavior of the real tissue. If this can be achieved then VR systems can be used not only to train surgeons but also to rehearse individual procedures where variations in anatomy or pathology present specific surgical problems. The European Union has recently funded a multinational 3-year project (IERAPSI, Integrated Environment for Rehearsal and Planning of Surgical Interventions) to produce a virtual reality system for surgical training and for rehearsing individual procedures. Building the IERAPSI system will bring together a wide range of experts and combine the latest technologies to produce a true, patient specific virtual reality surgical simulator for petrous/temporal bone procedures. This article presents a review of the “state of the art” technologies currently available to construct a system of this type and an overview of the functionality and specifications such a system requires

    Marker-free surgical navigation of rod bending using a stereo neural network and augmented reality in spinal fusion

    Full text link
    The instrumentation of spinal fusion surgeries includes pedicle screw placement and rod implantation. While several surgical navigation approaches have been proposed for pedicle screw placement, less attention has been devoted towards the guidance of patient-specific adaptation of the rod implant. We propose a marker-free and intuitive Augmented Reality (AR) approach to navigate the bending process required for rod implantation. A stereo neural network is trained from the stereo video streams of the Microsoft HoloLens in an end-to-end fashion to determine the location of corresponding pedicle screw heads. From the digitized screw head positions, the optimal rod shape is calculated, translated into a set of bending parameters, and used for guiding the surgeon with a novel navigation approach. In the AR-based navigation, the surgeon is guided step-by-step in the use of the surgical tools to achieve an optimal result. We have evaluated the performance of our method on human cadavers against two benchmark methods, namely conventional freehand bending and marker-based bending navigation in terms of bending time and rebending maneuvers. We achieved an average bending time of 231s with 0.6 rebending maneuvers per rod compared to 476s (3.5 rebendings) and 348s (1.1 rebendings) obtained by our freehand and marker-based benchmarks, respectively

    Unexpected case of ankle tuberculosis in a young professionals leading to delay in diagnosis

    Get PDF
    We report a case of a 38 year-old engineer presented with left ankle pain for 2 years and initially treated as gouty arthritis because of high serum uric acid. A year later his left ankle become swollen and plain radiograph showed soft tissue swelling around the ankle with normal articular surface and bone. An MRI investigation reported as gouty arthritis of ankle with tophi. While on treatment for gouty arthritis, he developed pus discharge from the swelling. The ankle pain also worsen and he was unable to weight bear on the affected leg. An incision and drainage shown pus from the ankle joint which grew pseudomonas aeruginosa. He was treated with intravenous followed by oral ciprofloxacin 250 mg bd. However his condition does not improved and a month after antibiotic treatment a repeated radiograph shows narrowing of joint space with irregular cortical destruction, osteopenic bone . suggestive of worsening of his septic arthritis. During this period he deny of having any fever, cough or night sweats. However he did notice some loss of weight and loss of appetite. He has worked in Africa and Russia before in petroleum industry. After 4 months of antibiotic and no sign of improvement, a biopsy and repeat culture was taken from the ankle which reveal tuberculous arthritis and positive for AFB culture. A plain chest radiograph revealed miliary tuberculosis picture. He was started on a anti TB treatment and the wound healed after a few weeks. After 4 months of treatment he was able to walk without support with reduce ankle range of motion. This case illustrate that the diagnosis was delay because tuberculosis was not suspected in a young professionals with ankle pain and elevated serum uric acid level. Further delay in diagnosis because MRI report also suggestive of gouty tophi and the pus culture and sensitivity grew pseudomonas aeruginosa

    ACCURACY OF A SACRAL DRILLING WITH A CUSTOM 3D PRINTED DRILLING GUIDE OR FREE-HAND TECHNIQUE IN CANINE EXPERIMENTAL SACROILIAC LUXATION

    Get PDF
    ABSTRACT The objective of this study was to improve the accuracy of drilling during the repair of sacroiliac luxation with a 3D-printed patient-specific drill guide (3D-GDT) compared to free-hand drilling technique (FHDT). A blinded, randomized, prospective study was performed including sixteen canine cadavers (20-25 kg) euthanized for reasons not related to the study. Dorsal, bilateral, sacroiliac luxations (SILs) were created experimentally. A pelvic CT was performed pre- and post-drilling. The FHDT was drilled followed by 3D-GDT for each sacrum. CT and 3D measurements of craniocaudal and dorsoventral angles were compared between FHDT and 3D-GDT, as well as deviations of entry and exit points relative to optimal trajectory. Mean craniocaudal and dorsoventral angles for both CT and 3D measured 3D-GDT (CT 4.2o±3.9 and 3.9o±3.2, respectively; 3D 5.1o±5.1 and 2.8o±2.3 respectively p=0.0006) were lower compared to FHDT (CT 11.8o±4.0, p o ±6.1, p=0.01; 3D 12.4o±5.9, p=0.0006 and 5.3o±5.24, p=0.05) respectively. Entry dorsoventral and end craniocaudal, dorsoventral and 3D linear deviations were reduced with the 3D-GDT. Sacral corridor disruption was present more in FHDT (20%, 3/15) than 3D-GDT (0%). CT and 3D analyses were in strong agreement (r=0.77). Deviations of drill trajectories were minimized relative to optimal trajectories with the 3D-GDT compared to the FHDT in the dorsoventral and craniocaudal planes. The 3D-GDT improves accuracy of sacral drilling compared to FHDT in canine cadavers

    Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events

    Get PDF
    BACKGROUND AND OBJECTIVE: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. METHODS: A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. RESULTS: A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4–6.6%) of ETFO, 28.6% (26.6–30.6%) of ESD, and 0.53% (0.2–1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1–1.3%), 11% (9.2–13.0%), and 3.2% (2.5–3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. CONCLUSION: Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications

    Augmented reality (AR) for surgical robotic and autonomous systems: State of the art, challenges, and solutions

    Get PDF
    Despite the substantial progress achieved in the development and integration of augmented reality (AR) in surgical robotic and autonomous systems (RAS), the center of focus in most devices remains on improving end-effector dexterity and precision, as well as improved access to minimally invasive surgeries. This paper aims to provide a systematic review of different types of state-of-the-art surgical robotic platforms while identifying areas for technological improvement. We associate specific control features, such as haptic feedback, sensory stimuli, and human-robot collaboration, with AR technology to perform complex surgical interventions for increased user perception of the augmented world. Current researchers in the field have, for long, faced innumerable issues with low accuracy in tool placement around complex trajectories, pose estimation, and difficulty in depth perception during two-dimensional medical imaging. A number of robots described in this review, such as Novarad and SpineAssist, are analyzed in terms of their hardware features, computer vision systems (such as deep learning algorithms), and the clinical relevance of the literature. We attempt to outline the shortcomings in current optimization algorithms for surgical robots (such as YOLO and LTSM) whilst providing mitigating solutions to internal tool-to-organ collision detection and image reconstruction. The accuracy of results in robot end-effector collisions and reduced occlusion remain promising within the scope of our research, validating the propositions made for the surgical clearance of ever-expanding AR technology in the future

    Intraoperative Planning and Execution of Arbitrary Orthopedic Interventions Using Handheld Robotics and Augmented Reality

    Get PDF
    The focus of this work is a generic, intraoperative and image-free planning and execution application for arbitrary orthopedic interventions using a novel handheld robotic device and optical see-through glasses (AR). This medical CAD application enables the surgeon to intraoperatively plan the intervention directly on the patient’s bone. The glasses and all the other instruments are accurately calibrated using new techniques. Several interventions show the effectiveness of this approach
    corecore