36 research outputs found

    Effects of sensor types and angular velocity computational methods in field measurements of occupational upper arm and trunk postures and movements

    Get PDF
    Accelerometer-based inclinometers have dominated kinematic measurements in previous field studies, while the use of inertial measurement units that additionally include gyroscopes is rapidly increasing. Recent laboratory studies suggest that these two sensor types and the two commonly used angular velocity computational methods may produce substantially different results. The aim of this study was, therefore, to evaluate the effects of sensor types and angular velocity computational methods on the measures of work postures and movements in a real occupational setting. Half-workday recordings of arm and trunk postures, and movements from 38 warehouse workers were compared using two sensor types: accelerometers versus accelerometers with gyroscopes—and using two angular velocity computational methods, i.e., inclination velocity versus generalized velocity. The results showed an overall small difference (<2\ub0 and value independent) for posture percentiles between the two sensor types, but substantial differences in movement percentiles both between the sensor types and between the angular computational methods. For example, the group mean of the 50th percentiles were for accelerometers: 71\ub0/s (generalized velocity) and 33\ub0/s (inclination velocity)—and for accelerometers with gyroscopes: 31\ub0/s (generalized velocity) and 16\ub0/s (inclination velocity). The significant effects of sensor types and angular computational methods on angular velocity measures in field work are important in inter-study comparisons and in comparisons to recommended threshold limit values

    Ergonomics

    Get PDF
    The accuracy and repeatability of an inertial measurement unit (IMU) system for directly measuring trunk angular displacement and upper arm elevation were evaluated over eight hours (i) in comparison to a gold standard, optical motion capture (OMC) system in a laboratory setting, and (ii) during a field-based assessment of dairy parlour work. Sample-to-sample root mean square differences between the IMU and OMC system ranged from 4.1\ub0 to 6.6\ub0 for the trunk and 7.2\ub0-12.1\ub0 for the upper arm depending on the processing method. Estimates of mean angular displacement and angular displacement variation (difference between the 90th and 10th percentiles of angular displacement) were observed to change\ua0<4.5\ub0 on average in the laboratory and\ua0<1.5\ub0 on average in the field per eight hours of data collection. Results suggest the IMU system may serve as an acceptable instrument for directly measuring trunk and upper arm postures in field-based occupational exposure assessment studies with long sampling durations. Practitioner Summary: Few studies have evaluated inertial measurement unit (IMU) systems in the field or over long sampling durations. Results of this study indicate that the IMU system evaluated has reasonably good accuracy and repeatability for use in a field setting over a long sampling duration.2022-09-13T00:00:00Z26256753PMC946963411892vault:4327

    Physical and digital architecture for collection and analysis of imparted accelerations on Zip Line attractions

    Get PDF
    The accelerations experienced by riders of Zip Line attractions is an underexplored area of public safety assurance. These amusement devices require complex processes to collect and analyze acceleration data. Highly versatile and effective rider-worn and ride-carried devices are necessary to collect acceleration and velocity data without affecting the integrity of the ride. This paper introduces the use of a sensor device for collecting Zip Line acceleration data in the form of a Trailing Trolley. This architecture extends the work of Sicat et. al.’s which proposed the use of a Sensor Vest and Headwear to collect linear and rotational accelerations of a Zip Line rider. We investigate the logistics of combining the two sensor platforms and formulate a procedure to post-process and analyze the data. Techniques to extract, filter, and process the accelerations recorded is discussed and the potential for the synthesis of positioning linear and rotational data is described. Additional testing of data collection and analysis is necessary to prove the viability of these techniques and apparatuses as potential parts of a standardized test method for measuring rider experienced g-forces on Zip Lines

    Comparison of wearable measurement systems for estimating trunk postures in manual material handling, A

    Get PDF
    2017 Fall.Includes bibliographical references.Epidemiologic studies have established that awkward trunk postures during manual materials handling are associated with an increased risk of developing occupational low back disorders. With recent advances in motion capture technology, emerging wearable measurement systems have been designed to quantify trunk postures for exposure assessments. Wearable measurement systems integrate portable microelectromechanical sensors, real-time processing algorithms, and large memory capacity to effectively quantify trunk postures. Wearable measurement systems have been available primarily as research tools, but are now quickly becoming accessible to health and safety professionals for industrial application. Although some of these systems can be highly complex and deter health and safety professionals from using them, other systems can serve as a simpler, more user-friendly alternative. These simple wearable measurement systems are designed to be less intricate, allowing health and safety professionals to be more willing to utilize them in occupational posture assessments. Unfortunately, concerns regarding the comparability and agreement between simple and complex wearable measurement systems for estimating trunk postures are yet to be fully addressed. Furthermore, application of wearable measurement systems has been affected by the lack of adaptability of sensor placement to work around obstructive equipment and bulky gear workers often wear on the job. The aims of the present study were to 1) compare the Bioharness™3, a simple wearable measurement system, to Xsens™, a complex wearable measurement system, for estimating trunk postures during simulated manual material handling tasks and 2) to explore the effects of Xsens sensor placement on assessing trunk postures. Thirty participants wore the two systems simultaneously during simulated tasks in the laboratory that involved reaching, lifting, lowering, and pushing a load for ten minutes. Results indicated that the Bioharness 3 and Xsens systems are comparable for strictly estimating trunk postures that involved flexion and extension of 30° or less. Although limited to a short range of trunk postures, the Bioharness also exhibited moderate to strong agreement and correlations with the Xsens system for measuring key metrics commonly used in exposure assessments, including amplitude probability distribution functions and percent time spent in specific trunk posture categories or bins. The Bioharness is suggested to be an a more intuitive alternative to the Xsens system for posture analysis, but industrial use of the device should be warranted in the context of the exposure assessment goals. In addition, a single motion sensor from the Xsens system placed on the sternum yielded comparable and consistent estimates to a sensor secured on the sternum relative to a motion sensor on the sacrum. Estimates included descriptive measures of trunk flexion and extension and percent time spent in specific trunk posture categories. Using one motion sensor instead of two may serve as an alternative for sensor placement configuration in situations where worker portable equipment or personal preference prevents preferred sensor placement

    Characterization of upper limb use in health care workers during regular shifts: A quantitative approach based on wrist-worn accelerometers

    Get PDF
    Despite the high prevalence of upper limb (UL) work-related musculoskeletal disorders (WRMSD) among health care workers (HCWs), little is known about their relationship with exposure to biomechanical risk factors. This study aimed to assess UL activity features under actual working conditions using two wrist-worn accelerometers. Accelerometric data were processed to obtain duration, intensity, and asymmetry of UL use in 32 HCWs during the execution of commonly performed tasks (e.g., patient hygiene, transfer, and meal distribution) within a regular shift. The results show that such tasks are characterized by significantly different patterns of UL use, in particular, higher intensities and larger asymmetries were observed respectively for patient hygiene and meal distribution. The proposed approach appears, thus, suitable to discriminate tasks characterized by different UL motion patterns. Future studies could benefit from the integration of such measures with self-reported workers’ perception to elucidate the relationship between dynamic UL movements and WRMSD

    Smart Sensors for Healthcare and Medical Applications

    Get PDF
    This book focuses on new sensing technologies, measurement techniques, and their applications in medicine and healthcare. Specifically, the book briefly describes the potential of smart sensors in the aforementioned applications, collecting 24 articles selected and published in the Special Issue “Smart Sensors for Healthcare and Medical Applications”. We proposed this topic, being aware of the pivotal role that smart sensors can play in the improvement of healthcare services in both acute and chronic conditions as well as in prevention for a healthy life and active aging. The articles selected in this book cover a variety of topics related to the design, validation, and application of smart sensors to healthcare

    A Monitoring System to Reduce Shoulder Injury Among Construction Workers

    Get PDF
    As the work force ages and workers retirement age increases, the number of workers suffering from Work-related Musculoskeletal Disorders (WMSDs) has increased. In a recent study, the U.S Bureau of Labor reported that 6.9% of all WMSDs affected shoulders. Electricians, carpenters, and related construction crafts appear to experience higher incidence of these injuries due the nature of their work that require them often to use Awkward shoulder postures. This research aims to develop a new monitoring system that measure the amount of time workers spend in awkward shoulder postures to help decrease the prevalence of cumulative shoulder injuries and to reduce the number of cases of shoulder WMSDs among construction workers. The monitoring system was designed and a feasibility study was conduct to compare the monitoring system with a state of the art motion tracking system. Overall the monitoring system was able to count the time spent in awkward posture as a discrete state sensor and it can be implemented in the field. However, results showed that the monitoring system in its current configuration require some future work for it to produce quantitatively precise results that can be used in the fields of biomechanics, robotics, and ergonomics

    Biomechanics of the Upper Extremity in Response to Dynamic Impact Loading Indicative of a Forward Fall: An Experimental and Numerical Investigation.

    Get PDF
    The distal radius is one of the most common fracture sites in humans, often resulting from a forward fall with more than 60 % of all fractures to the wrist requiring some form of surgical intervention. Although there is a general consensus regarding the risk factors for distal radius fractures resulting from forward falling, prevention of these injuries requires a more thorough understanding of the injury mechanisms. Therefore the overall purpose of this dissertation was to assess the response of the upper extremity to impact loading to improve the understanding of distal radius fracture mechanisms and the effectiveness of joint kinematic strategies for reducing the impact effects. Three main studies were conducted that utilized in vivo, in vitro and numerical techniques. In vitro impact testing of the distal radius revealed that fracture will occur at a mean (SD) resultant impact force and velocity of 2142.1(1228.7) N and 3.4 (0.7) m/s, respectively. Based on the failure data, multi-variate injury criteria models were produced, highlighting the dynamic and multidirectional nature of distal radius fractures The in vitro investigation was also used to develop and validate a finite element model of the distal radius. Dynamic impacts were simulated in LS-DYNA and the resulting z-axis force validation metrics (0.23-0.54) suggest that this is a valid model. A comparison of the experimental fracture patterns to those predicted numerically (i.e. von-Mises stress criteria) shows the finite element model is capable of accurately predicting bone failure